Understanding of self-terminating pulse generation using silicon controlled rectifier and RC load
Open Access
- 1 January 2016
- journal article
- Published by AIP Publishing in AIP Advances
- Vol. 6 (1) , 015209
Abstract
Recently a silicon controlled rectifier (SCR)-based circuit that generates self-terminating voltage pulses was employed for the detection of light and ionizing radiation in pulse mode. The circuit consisted of a SCR connected in series with a RC load and DC bias. In this paper, we report the investigation of the physics underlying the pulsing mechanism of the SCR-based. It was found that during the switching of SCR, the voltage across the capacitor increased beyond that of the DC bias, thus generating a reverse current in the circuit, which helped to turn the SCR off. The pulsing was found to be sustainable only for a specific range of RC values depending on the SCR’s intrinsic turn-on/off times. The findings of this work will help to design optimum SCR based circuits for pulse mode detection of light and ionizing radiation without external amplification circuitry.Keywords
This publication has 5 references indexed in Scilit:
- A solid-state spark chamber for detection of ionizing radiationSensors and Actuators A: Physical, 2014
- Fundamentals of Power Semiconductor Devices2008
- Spontaneous pulse generation using silicon controlled rectifierApplied Physics Letters, 2006
- Perceptual thresholds and electrode impedance in three retinal prosthesis subjectsIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Optical CMOS sensor system for detection of light sourcesSensors and Actuators A: Physical, 2003