Compatibility Between the Intraocular Lens Master and Pentacam Devices in White-to-White Measurements Used in Phakic Intraocular Lens Calculations
Authors:
- Mine Koru ToprakMTMine Koru Toprak
- Aydin ToprakATAydin Toprak
- Bekir AyyildizBABekir Ayyildiz
- Mutluay BozokluMBMutluay Bozoklu
- Deniz KilicDKDeniz Kilic
Open Access
- 1 January 2025
- journal article
- Published by Kare Publishing in Beyoglu Eye Journal
- Vol. 10 (4) , 206-210
Abstract
Measurement of white-to-white (WtW) distance is essential in the pre-operative evaluation of candidates for cataract or refractive surgery, and in determining the appropriate haptic size of newly developed phakic intraocular lenses (IOLs). This distance can be measured quickly and easily using various methods. However, inconsistencies among reported results raise concerns about whether these measurements can be used interchangeably. Although previous studies have analyzed the agreement between different devices, there has been no such study conducted at the national level. Based on this, our study aimed to analyze the agreement between WtW measurements obtained by the IOLMaster 500 and Pentacam devices for use in phakic IOL (pIOL) calculations. A total of 66 eyes from 66 candidates for cataract or refractive surgery were included in the study. WtW distance measurements obtained from both devices were recorded and analyzed. A one-sample t-test was used to compare the mean WtW values. Bland-Altman analysis was performed to assess the agreement between the two devices. The mean age of the participants was 63.42±18.27 years, and 20 (60.6%) were male. The mean WtW distances measured by the IOLMaster 500 and Pentacam were 11.80±0.48 mm and 11.50±0.56 mm, respectively (p<0.001) (limits of agreement: Lower limit 0.19, upper limit 0.41; 95% confidence interval). Our study showed that the IOLMaster 500 measured significantly higher WtW distances compared to the Pentacam. Therefore, these two devices should not be used interchangeably for WtW measurements. We recommend using the devices endorsed by the chosen pIOL manufacturer.Keywords
This publication has 10 references indexed in Scilit:
- Preoperative biometric measurements with anterior segment optical coherence tomography and prediction of postoperative intraocular lens positionMedicine, 2019
- Agreement of Corneal Diameter Measurements Obtained by a Swept-source Biometer and a Scheimpflug-based TopographerCornea, 2017
- Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature reviewInternational Journal of Ophthalmology, 2016
- Comparison of Corneal Diameter and Anterior Chamber Depth Measurements Using 4 Different DevicesCornea, 2016
- Interchangeability between Pentacam and IOLMaster in Phakic Intraocular Lens CalculationEuropean Journal of Ophthalmology, 2014
- Comparison of Horizontal Corneal Diameter Measurements Using the Orbscan IIz and Pentacam HR SystemsCornea, 2013
- Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential ComplicationsJournal of Refractive Surgery, 2011
- Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometerGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systemsClinical and Experimental Optometry, 2009
- Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurementsJournal of Cataract & Refractive Surgery, 2006