Long-term follow-up of bone remodelling after cementless hip arthroplasty using different stems
Open Access
- 23 June 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
Abstract
The present paper is concerned with the investigation of the phenomenon of long-term bone remodelling on cementless hip replacements. Changes in bone density in the periprosthetic region around the stem, measured by dual X–ray absorptiometry (DXA), were used as a measure of the osseous adaptation reaction. A postoperative follow-up of the use of four different types of prostheses of varying design after on average 13.3 (11.4–14.5) years. Specifically, the prostheses assessed in this study were the CLS/Spotorno stem with the Allofit cup by Zimmer, the Vision 2000 stem with the Duraloc cup by DePuy Synthes, the AlphaFit stem with the AlphaLock cup by Corin and the Mayo stem with the Trilogy cup by Zimmer. For the DXA measurement, the femur was divided into the zones suggested by Gruenet al. On the femur, there was a significant reduction in bone mineral density (BMD) in the proximal Region Of Interest (ROI) 1 (p = 0.003) and 7 (p < 0.001), whilst there was a significant increase in ROI 4 (p = 0.03). A greater degree of bone atrophy was seen in patients aged 60 years and older and in female patients. A remarkable finding when comparing the stems was a significantly greater reduction in BMD in ROI 6 (p = 0.003) in the case of the Vision 2000 stem and a markedly, but not statistically significantly smaller reduction in BMD in ROI 7 (p = 0.18) in the case of the short-stem Mayo-type prosthesis. The best clinical results were found with the use of the latter. The investigations provide a starting point for establishing a differential indication in the choice of prosthesis types, depending on age and sex, the use of short-stem prostheses, as well as the administration of bone-effective drugs for the prevention of stress shielding.Keywords
This publication has 22 references indexed in Scilit:
- Subsidence of a cementless femoral component influenced by body weight and body mass indexInternational Orthopaedics, 2011
- A Prospective Randomised Study of Periprosthetic Femoral Bone Remodeling Using Four Different Bearings in Hybrid Total Hip ArthroplastyHIP International, 2011
- Female patients with low systemic BMD are prone to bone loss in Gruen zone 7 after cementless total hip arthroplastyActa Orthopaedica, 2009
- Continuous bone loss around a tapered uncemented femoral stem: A long-term evaluation with DEXAActa Orthopaedica, 2006
- The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplastyThe Journal of Arthroplasty, 2004
- Radiologische Veränderungen nach Implantation zweier unterschiedlicher zementfreier HüftschaftsystemeRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1997
- Periprosthetic Bone Loss and Regional Bone Turnover in Uncemented Total Hip Arthroplasty: A Prospective Study Using High Resolution Single Photon Emission Tomography and Dual-Energy X-Ray AbsorptiometryJournal of Bone and Mineral Research, 1997
- Periprothetische Mineralisationsdichte zementfreier HüftendoprothetikZeitschrift für Orthopädie und ihre Grenzgebiete, 1997
- Sex differences in age‐related remodeling of the femur and tibiaJournal of Orthopaedic Research, 1988
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979