Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit
Open Access
- 31 May 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (1) , 258-268
Abstract
The aim of this study was to evaluate the performance of a closed circuit MR compatible pneumatically driven pump system using a ventricular assist device as pulsatile flow pump for in vitro 3D flow simulation. Additionally, a pressure control unit was integrated into the flow circuit. The performance of the pump system and its test‐retest reliability was evaluated using a stenosis phantom (60% lumen narrowing). Bland–Altman analysis revealed a good test–retest reliability (mean differences = −0.016 m/s, limits of agreement = ±0.047 m/s) for in vitro flow measurements. Furthermore, a rapid prototyping in vitro model of a normal thoracic aorta was integrated into the flow circuit for a direct comparison of flow characteristics with in vivo data in the same subject. The pneumatically driven ventricular assist device was attached to the ascending aorta of the in vitro model to simulate the beating left ventricle. In the descending part of the healthy aorta a flexible stenosis was integrated to model an aortic coarctation. In vivo and in vitro comparison showed significant (P = 0.002) correlations (r = 0.9) of mean velocities. The simulation of increasing coarctation grade led to expected changes in the flow patterns such as jet flow in the post‐stenotic region and increased velocities. Magn Reson Med, 2011.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (MA 2383/5-1)
- The Bundesministerium für Bildung und Forschung (01EV0706)
This publication has 35 references indexed in Scilit:
- Simulation of phase contrast MRI of turbulent flowMagnetic Resonance in Medicine, 2010
- Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamicsNeuroradiology, 2009
- Investigation of Pulsatile Flowfield in Healthy Thoracic Aorta ModelsAnnals of Biomedical Engineering, 2009
- 3D MR flow analysis in realistic rapid‐prototyping model systems of the thoracic aorta: Comparison with in vivo data and computational fluid dynamics in identical vessel geometriesMagnetic Resonance in Medicine, 2008
- Time‐resolved three‐dimensional phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2003
- MRI measurement of time‐resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictionsJournal of Magnetic Resonance Imaging, 2003
- Combined MRI and CFD analysis of fully developed steady and pulsatile laminar flow through a bendJournal of Magnetic Resonance Imaging, 1998
- Temporally resolved 3D phase‐contrast imagingMagnetic Resonance in Medicine, 1996
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986