Ramona Lorenz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ramona Lorenz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jan Gerrit Korvink
Institute of Microstructure Technology Karlsruhe Institute of Technology Eggenstein‐Leopoldshafen Germany
3 shared publications J. Bock
Department of Radiology Medical Physics, University Medical Center Freiburg Germany
2 shared publicationsM. Markl
Department of Radiology Feinberg School of Medicine, Northwestern University Chicago Illinois USA
2 shared publications- Alex J. Barker
Department of Radiology, Section of Pediatric Radiology, Children's Hospital Colorado University of Colorado Anschutz Medical Campus Aurora Colorado USA
1 shared publication - Aurelien F. Stalder
Siemens Healthcare, Erlangen, Germany
1 shared publication Bernd A. Jung
Dept. of Radiology, Medical Physics, University Medical Center Freiburg, Germany
1 shared publication
Latest Publications
- 4 September 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (1) , 33-40
Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data
Purpose The measurement of velocities based on phase contrast MRI can be subject to different phase offset errors which can affect the accuracy of velocity data. The purpose of this study was to determine the impact of these inaccuracies and to evaluate different correction strategies on three‐dimensional visualization. Methods Phase contrast MRI was performed on a 3 T system (Siemens Trio) for in vitro (curved/straight tube models; venc: 0.3 m/s) and in vivo (aorta/intracranial vasculature; venc: 1.5/0.4 m/s) data. For comparison of the impact of different magnetic field gradient designs, in vitro data was additionally acquired on a wide bore 1.5 T system (Siemens Espree). Different correction methods were applied to correct for eddy currents, Maxwell terms, and gradient field inhomogeneities. Results The application of phase offset correction methods lead to an improvement of three‐dimensional particle trace visualization and count. The most pronounced differences were found for in vivo/in vitro data (68%/82% more particle traces) acquired with a low venc (0.3 m/s/0.4 m/s, respectively). In vivo data acquired with high venc (1.5 m/s) showed noticeable but only minor improvement. Conclusion This study suggests that the correction of phase offset errors can be important for a more reliable visualization of particle traces but is strongly dependent on the velocity sensitivity, object geometry, and gradient coil design. Magn Reson Med 72:33–40, 2014.
- 4 September 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (1) , 33-40
Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data
Purpose The measurement of velocities based on phase contrast MRI can be subject to different phase offset errors which can affect the accuracy of velocity data. The purpose of this study was to determine the impact of these inaccuracies and to evaluate different correction strategies on three‐dimensional visualization. Methods Phase contrast MRI was performed on a 3 T system (Siemens Trio) for in vitro (curved/straight tube models; venc: 0.3 m/s) and in vivo (aorta/intracranial vasculature; venc: 1.5/0.4 m/s) data. For comparison of the impact of different magnetic field gradient designs, in vitro data was additionally acquired on a wide bore 1.5 T system (Siemens Espree). Different correction methods were applied to correct for eddy currents, Maxwell terms, and gradient field inhomogeneities. Results The application of phase offset correction methods lead to an improvement of three‐dimensional particle trace visualization and count. The most pronounced differences were found for in vivo/in vitro data (68%/82% more particle traces) acquired with a low venc (0.3 m/s/0.4 m/s, respectively). In vivo data acquired with high venc (1.5 m/s) showed noticeable but only minor improvement. Conclusion This study suggests that the correction of phase offset errors can be important for a more reliable visualization of particle traces but is strongly dependent on the velocity sensitivity, object geometry, and gradient coil design. Magn Reson Med 72:33–40, 2014.
- Open Access
- 28 May 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (4) , 1542-1553
4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicity
Purpose: Changes in aortic geometry or presence of aortic valve (AoV) disease can result in substantially altered aortic hemodynamics. Dilatation of the ascending aorta or AoV abnormalities can result in an increase in helical flow.Methods: 4D flow magnetic resonance imaging was used to test the feasibility of quantitative helicity analysis using equidistantly distributed 2D planes along the entire aorta. The evaluation of the method included three parts: (1) the quantification of helicity in 12 healthy subjects, (2) an evaluation of observer variability and test–retest reliability, and (3) the quantification of helical flow in 16 patients with congenitally altered bicuspid AoVs.Results: Helicity quantification in healthy subjects revealed consistent directions of flow rotation along the entire aorta with high clockwise helicity in the aortic arch and an opposite rotation sense in the ascending and descending aorta. The results demonstrated good scan–rescan and inter‐ and intraobserver agreement of the helicity parameters. Helicity quantification in patients revealed a significant increase in absolute peak relative helicity during systole and a considerably greater heterogeneous distribution of mean helicity in the aorta.Conclusion: The method has the potential to serve as a reference distribution for comparisons of helical flow between healthy subjects and patients or between different patient groups. Magn Reson Med 71:1542–1553, 2014. © 2013 Wiley Periodicals, Inc.
- 28 May 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (4) , 1542-1553
Open Access4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicity
Purpose: Changes in aortic geometry or presence of aortic valve (AoV) disease can result in substantially altered aortic hemodynamics. Dilatation of the ascending aorta or AoV abnormalities can result in an increase in helical flow.Methods: 4D flow magnetic resonance imaging was used to test the feasibility of quantitative helicity analysis using equidistantly distributed 2D planes along the entire aorta. The evaluation of the method included three parts: (1) the quantification of helicity in 12 healthy subjects, (2) an evaluation of observer variability and test–retest reliability, and (3) the quantification of helical flow in 16 patients with congenitally altered bicuspid AoVs.Results: Helicity quantification in healthy subjects revealed consistent directions of flow rotation along the entire aorta with high clockwise helicity in the aortic arch and an opposite rotation sense in the ascending and descending aorta. The results demonstrated good scan–rescan and inter‐ and intraobserver agreement of the helicity parameters. Helicity quantification in patients revealed a significant increase in absolute peak relative helicity during systole and a considerably greater heterogeneous distribution of mean helicity in the aorta.Conclusion: The method has the potential to serve as a reference distribution for comparisons of helical flow between healthy subjects and patients or between different patient groups. Magn Reson Med 71:1542–1553, 2014. © 2013 Wiley Periodicals, Inc.
- Open Access
- 31 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (1) , 258-268
Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit
The aim of this study was to evaluate the performance of a closed circuit MR compatible pneumatically driven pump system using a ventricular assist device as pulsatile flow pump for in vitro 3D flow simulation. Additionally, a pressure control unit was integrated into the flow circuit. The performance of the pump system and its test‐retest reliability was evaluated using a stenosis phantom (60% lumen narrowing). Bland–Altman analysis revealed a good test–retest reliability (mean differences = −0.016 m/s, limits of agreement = ±0.047 m/s) for in vitro flow measurements. Furthermore, a rapid prototyping in vitro model of a normal thoracic aorta was integrated into the flow circuit for a direct comparison of flow characteristics with in vivo data in the same subject. The pneumatically driven ventricular assist device was attached to the ascending aorta of the in vitro model to simulate the beating left ventricle. In the descending part of the healthy aorta a flexible stenosis was integrated to model an aortic coarctation. In vivo and in vitro comparison showed significant (P = 0.002) correlations (r = 0.9) of mean velocities. The simulation of increasing coarctation grade led to expected changes in the flow patterns such as jet flow in the post‐stenotic region and increased velocities. Magn Reson Med, 2011.
- 31 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (1) , 258-268
Open AccessClosed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit
The aim of this study was to evaluate the performance of a closed circuit MR compatible pneumatically driven pump system using a ventricular assist device as pulsatile flow pump for in vitro 3D flow simulation. Additionally, a pressure control unit was integrated into the flow circuit. The performance of the pump system and its test‐retest reliability was evaluated using a stenosis phantom (60% lumen narrowing). Bland–Altman analysis revealed a good test–retest reliability (mean differences = −0.016 m/s, limits of agreement = ±0.047 m/s) for in vitro flow measurements. Furthermore, a rapid prototyping in vitro model of a normal thoracic aorta was integrated into the flow circuit for a direct comparison of flow characteristics with in vivo data in the same subject. The pneumatically driven ventricular assist device was attached to the ascending aorta of the in vitro model to simulate the beating left ventricle. In the descending part of the healthy aorta a flexible stenosis was integrated to model an aortic coarctation. In vivo and in vitro comparison showed significant (P = 0.002) correlations (r = 0.9) of mean velocities. The simulation of increasing coarctation grade led to expected changes in the flow patterns such as jet flow in the post‐stenotic region and increased velocities. Magn Reson Med, 2011.