Application of a new microcantilever biosensor resonating at the air–liquid interface for direct insulin detection and continuous monitoring of enzymatic reactions
- 6 July 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (20) , 4115-4119
Abstract
Here we describe the application of a recently developed high-resolution microcantilever biosensor resonating at the air–liquid interface for the continuous detection of antigen–antibody and enzyme–substrate interactions. The cantilever at the air–liquid interface demonstrated 50% higher quality factor and a 5.7-fold increase in signal-to-noise-ratio (SNR) compared with one immersed in the purified water. First, a label-free detection of a low molecular weight protein (insulin, 5.8 kDa) in physiological concentration was demonstrated. The liquid facing side of the cantilever was functionalized by coating its surface with insulin antibodies, while the opposite side was exposed to air. The meniscus membrane at the micro-slit around the cantilever sustained the liquid in the microchannel. After optimizing the process of surface functionalization, the resonance frequency shift was successfully measured for insulin solutions of 0.4, 2.0, and 6.3 ng ml−1. To demonstrate additional application of the device for monitoring enzymatic protein degradation, the liquid facing microcantilever surface was coated with human recombinant SOD1 (superoxide dismutase 1) and exposed to various concentrations of proteinase K solution, and the kinetics of the SOD1 digestion was continuously monitored. The results showed that it is a suitable tool for sensitive protein detection and analysis.Keywords
This publication has 31 references indexed in Scilit:
- High-resolution cantilever biosensor resonating at air–liquid in a microchannelLab on a Chip, 2011
- Advanced Glycation End Products Are Direct Modulators of β-Cell FunctionDiabetes, 2011
- Real-time QCM-D monitoring of cellular responses to different cytomorphic agentsBiosensors and Bioelectronics, 2011
- Detection of Hepatitis B Virus (HBV) DNA at femtomolar concentrations using a silica nanoparticle-enhanced microcantilever sensorBiosensors and Bioelectronics, 2009
- Sensitivity enhancement of a dynamic mode microcantilever by stress inducer and mass inducer to detect PSA at low picogram levelsLab on a Chip, 2009
- Rapid generation of protein aerosols and nanoparticles via surface acoustic wave atomizationNanotechnology, 2008
- Fibril specific, conformation dependent antibodies recognize a generic epitope common to amyloid fibrils and fibrillar oligomers that is absent in prefibrillar oligomersMolecular Neurodegeneration, 2007
- Tuning the number density of nanoparticles by multivariant tailoring of attachment points on flat substratesNanotechnology, 2006
- Rapid Biosensor for Detection of Antibiotic-Selective Growth of Escherichia coliApplied and Environmental Microbiology, 2005
- IMMUNOASSAY OF ENDOGENOUS PLASMA INSULIN IN MANJournal of Clinical Investigation, 1960