Hiroyuki Fujita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroyuki Fujita has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Stanislav L. Karsten
Department of Micro Engineering, Kyoto University , Kyoto Daigaku-Katsura, Nishikyo-ku, Kyoto 615-8540, Japan
2 shared publications Anthony J. Genot
LIMMS/CNRS-Institute of Industrial Science, The University of Tokyo
1 shared publication- Chann Lagadec
Univ. Lille, CNRS, Inserm, CHU Lille, Centre Oscar Lambret, UMR9020 CNRS - U1366 Inserm - CRCLille – Centre de Recherches en Cancérologie de Lille, Université de Lille
1 shared publication - Daiki Tanaka
Faculty of Advanced Science and Engineering, Waseda University, Tokyo 162-0041, Japan
1 shared publication - Dominique Collard
LIMMS/CNRS-IIS
1 shared publication - Gen Hashiguchi
Shizuoka Univ, Dept Mech Engn, 3-5-1 Johoku,Naka Ku, Hamamatsu, Shizuoka 4328011, Japan
1 shared publication
Latest Publications
- Open Access
Efficient Separation of Methanol Single-Micron Droplets by Tailing Phenomenon Using a PDMS Microfluidic Device
Microdroplet-based fluidic systems have the advantages of small size, short diffusion time, and no cross-contamination; consequently, droplets often provide a fast and precise reaction environment as well as an analytical environment for individual molecules. In order to handle diverse reactions, we developed a method to create organic single-micron droplets (S-MDs) smaller than 5 μm in diameter dispersed in silicone oil without surfactant. The S-MD generation microflow device consists of a mother droplet (MoD) generator and a tapered separation channel featuring multiple side channels. The tapered channel enhanced the shear forces to form tails from the MoDs, causing them to break up. Surface treatment with the fluoropolymer CYTOP protected PDMS fluid devices from organic fluids. The tailing separation of methanol droplets was accomplished without the use of surfactants. The generation of tiny organic droplets may offer new insights into chemical separation and help study the scaling effects of various chemical reactions.
Open AccessEfficient Separation of Methanol Single-Micron Droplets by Tailing Phenomenon Using a PDMS Microfluidic Device
Microdroplet-based fluidic systems have the advantages of small size, short diffusion time, and no cross-contamination; consequently, droplets often provide a fast and precise reaction environment as well as an analytical environment for individual molecules. In order to handle diverse reactions, we developed a method to create organic single-micron droplets (S-MDs) smaller than 5 μm in diameter dispersed in silicone oil without surfactant. The S-MD generation microflow device consists of a mother droplet (MoD) generator and a tapered separation channel featuring multiple side channels. The tapered channel enhanced the shear forces to form tails from the MoDs, causing them to break up. Surface treatment with the fluoropolymer CYTOP protected PDMS fluid devices from organic fluids. The tailing separation of methanol droplets was accomplished without the use of surfactants. The generation of tiny organic droplets may offer new insights into chemical separation and help study the scaling effects of various chemical reactions.
- Open Access
- 1 June 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (6) , 275
Developing a MEMS Device with Built-in Microfluidics for Biophysical Single Cell Characterization
This study combines the high-throughput capabilities of microfluidics with the sensitive measurements of microelectromechanical systems (MEMS) technology to perform biophysical characterization of circulating cells for diagnostic purposes. The proposed device includes a built-in microchannel that is probed by two opposing tips performing compression and sensing separately. Mechanical displacement of the compressing tip (up to a maximum of 14 µm) and the sensing tip (with a quality factor of 8.9) are provided by two separate comb-drive actuators, and sensing is performed with a capacitive displacement sensor. The device is designed and developed for simultaneous electrical and mechanical measurements. As the device is capable of exchanging the liquid inside the channel, different solutions were tested consecutively. The performance of the device was evaluated by introducing varying concentrations of glucose (from 0.55 mM (0.1%) to 55.5 mM (10%)) and NaCl (from 0.1 mM to 10 mM) solutions in the microchannel and by monitoring changes in the mechanical and electrical properties. Moreover, we demonstrated biological sample handling by capturing single cancer cells. These results show three important capabilities of the proposed device: mechanical measurements, electrical measurements, and biological sample handling. Combined in one device, these features allow for high-throughput multi-parameter characterization of single cells.
- 1 June 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (6) , 275
Open AccessDeveloping a MEMS Device with Built-in Microfluidics for Biophysical Single Cell Characterization
This study combines the high-throughput capabilities of microfluidics with the sensitive measurements of microelectromechanical systems (MEMS) technology to perform biophysical characterization of circulating cells for diagnostic purposes. The proposed device includes a built-in microchannel that is probed by two opposing tips performing compression and sensing separately. Mechanical displacement of the compressing tip (up to a maximum of 14 µm) and the sensing tip (with a quality factor of 8.9) are provided by two separate comb-drive actuators, and sensing is performed with a capacitive displacement sensor. The device is designed and developed for simultaneous electrical and mechanical measurements. As the device is capable of exchanging the liquid inside the channel, different solutions were tested consecutively. The performance of the device was evaluated by introducing varying concentrations of glucose (from 0.55 mM (0.1%) to 55.5 mM (10%)) and NaCl (from 0.1 mM to 10 mM) solutions in the microchannel and by monitoring changes in the mechanical and electrical properties. Moreover, we demonstrated biological sample handling by capturing single cancer cells. These results show three important capabilities of the proposed device: mechanical measurements, electrical measurements, and biological sample handling. Combined in one device, these features allow for high-throughput multi-parameter characterization of single cells.
- Open Access
- 28 September 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (10) , 293
Development of a Cantilever-Type Electrostatic Energy Harvester and Its Charging Characteristics on a Highway Viaduct
We have developed a micro-electro-mechanical systems (MEMS) electrostatic vibratory power generator with over 100 W of (root-mean-square) output electric power under 0.03 G (G: the acceleration of gravity) accelerations. The device is made of a silicon-on-insulator (SOI) wafer and is fabricated by silicon micromachining technology. An electret built-in potential is given to the device by electrothermal polarization in silicon oxide using potassium ions. The force factor, which is defined by a proportional coefficient of the output current with respect to the vibration velocity, is 2.34 × 10 C/m; this large value allows the developed vibration power generator to have a very high power efficiency of 80.7%. We have also demonstrated a charging experiment by using an environmental acceleration waveform with an average amplitude of about 0.03 G taken at a viaduct of a highway, and we obtained 4.8 mJ of electric energy stored in a 44 F capacitor in 90 min.- 28 September 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (10) , 293
Open AccessDevelopment of a Cantilever-Type Electrostatic Energy Harvester and Its Charging Characteristics on a Highway Viaduct
We have developed a micro-electro-mechanical systems (MEMS) electrostatic vibratory power generator with over 100 W of (root-mean-square) output electric power under 0.03 G (G: the acceleration of gravity) accelerations. The device is made of a silicon-on-insulator (SOI) wafer and is fabricated by silicon micromachining technology. An electret built-in potential is given to the device by electrothermal polarization in silicon oxide using potassium ions. The force factor, which is defined by a proportional coefficient of the output current with respect to the vibration velocity, is 2.34 × 10 C/m; this large value allows the developed vibration power generator to have a very high power efficiency of 80.7%. We have also demonstrated a charging experiment by using an environmental acceleration waveform with an average amplitude of about 0.03 G taken at a viaduct of a highway, and we obtained 4.8 mJ of electric energy stored in a 44 F capacitor in 90 min. - Open Access
- 1 November 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 773 (1) , 012104
Self-Pumped Coolant Circulation Driven by Thermal Gradient over Microstructures
We propose a passive cooling device which converts thermal energy into fluid flow via Marangoni effect: a gradient of temperature induces a gradient of surface tension. This in turn triggers a fluid flow at the air/liquid interface which runs transversally to the heat flow. We show how to amplify the global fluid flow thanks to geometrical optimization. We also show how the addition of an asymmetric small wall across the channel reduces the backflow and improves our device.
- 1 November 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 773 (1) , 012104
Open AccessSelf-Pumped Coolant Circulation Driven by Thermal Gradient over Microstructures
We propose a passive cooling device which converts thermal energy into fluid flow via Marangoni effect: a gradient of temperature induces a gradient of surface tension. This in turn triggers a fluid flow at the air/liquid interface which runs transversally to the heat flow. We show how to amplify the global fluid flow thanks to geometrical optimization. We also show how the addition of an asymmetric small wall across the channel reduces the backflow and improves our device.
- 6 July 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (20) , 4115-4119
Application of a new microcantilever biosensor resonating at the air–liquid interface for direct insulin detection and continuous monitoring of enzymatic reactions
Here we describe the application of a recently developed high-resolution microcantilever biosensor resonating at the air–liquid interface for the continuous detection of antigen–antibody and enzyme–substrate interactions. The cantilever at the air–liquid interface demonstrated 50% higher quality factor and a 5.7-fold increase in signal-to-noise-ratio (SNR) compared with one immersed in the purified water. First, a label-free detection of a low molecular weight protein (insulin, 5.8 kDa) in physiological concentration was demonstrated. The liquid facing side of the cantilever was functionalized by coating its surface with insulin antibodies, while the opposite side was exposed to air. The meniscus membrane at the micro-slit around the cantilever sustained the liquid in the microchannel. After optimizing the process of surface functionalization, the resonance frequency shift was successfully measured for insulin solutions of 0.4, 2.0, and 6.3 ng ml−1. To demonstrate additional application of the device for monitoring enzymatic protein degradation, the liquid facing microcantilever surface was coated with human recombinant SOD1 (superoxide dismutase 1) and exposed to various concentrations of proteinase K solution, and the kinetics of the SOD1 digestion was continuously monitored. The results showed that it is a suitable tool for sensitive protein detection and analysis.
- 6 July 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (20) , 4115-4119
Application of a new microcantilever biosensor resonating at the air–liquid interface for direct insulin detection and continuous monitoring of enzymatic reactions
Here we describe the application of a recently developed high-resolution microcantilever biosensor resonating at the air–liquid interface for the continuous detection of antigen–antibody and enzyme–substrate interactions. The cantilever at the air–liquid interface demonstrated 50% higher quality factor and a 5.7-fold increase in signal-to-noise-ratio (SNR) compared with one immersed in the purified water. First, a label-free detection of a low molecular weight protein (insulin, 5.8 kDa) in physiological concentration was demonstrated. The liquid facing side of the cantilever was functionalized by coating its surface with insulin antibodies, while the opposite side was exposed to air. The meniscus membrane at the micro-slit around the cantilever sustained the liquid in the microchannel. After optimizing the process of surface functionalization, the resonance frequency shift was successfully measured for insulin solutions of 0.4, 2.0, and 6.3 ng ml−1. To demonstrate additional application of the device for monitoring enzymatic protein degradation, the liquid facing microcantilever surface was coated with human recombinant SOD1 (superoxide dismutase 1) and exposed to various concentrations of proteinase K solution, and the kinetics of the SOD1 digestion was continuously monitored. The results showed that it is a suitable tool for sensitive protein detection and analysis.