The Influence of Verification Jig on Framework Fit for Nonsegmented Fixed Implant‐Supported Complete Denture
Authors:
- Carlo ErcoliCECarlo Ercoli
- Alessandro GeminianiAGAlessandro Geminiani
- Heeje LeeHLHeeje Lee
- 16 December 2011
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (s1) , e188-e195
Abstract
Purpose: The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant‐supported full‐arch prosthesis framework is fabricated with or without the aid of a verification jig.Materials and Methods: This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant‐supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try‐in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive.Results: When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001).Conclusions: Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant‐supported complete denture.Keywords
This publication has 14 references indexed in Scilit:
- The accuracy of implant impressions: A systematic reviewThe Journal of Prosthetic Dentistry, 2008
- Comparison of the transfer precision of three different impression materials in combination with transfer caps for the Frialit®‐2 systemJournal of Oral Rehabilitation, 2000
- Implant position record and implant position cast: Minimizing errors, procedures and patient visits in the fabrication of the milled-bar prosthesisThe Journal of Prosthetic Dentistry, 2000
- Clinical methods for evaluating implant framework fitThe Journal of Prosthetic Dentistry, 1999
- A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant systemThe Journal of Prosthetic Dentistry, 1997
- The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fitThe Journal of Prosthetic Dentistry, 1996
- An Evaluation of Fit in Osseointegrated Implant Components Using Torque/Turn AnalysisJournal of Prosthodontics, 1994
- Segmental framework matrix: Master cast verification, corrected cast guide, and analog transfer template for implant-supported prosthesesThe Journal of Prosthetic Dentistry, 1994
- Biomechanical factors affecting the bone-dental implant interfaceClinical Materials, 1992
- Osseointegrated dental implants: Preliminary report on a replication studyThe Journal of Prosthetic Dentistry, 1983