AGAlessandro Geminiani

Alessandro Geminiani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alessandro Geminiani has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Carlo Ercoli

    Professor, Departments of Prosthodontics and Periodontology, Eastman Institute for Oral Health University of Rochester, Rochester, NY; Chairman, Department of Prosthodontics, Eastman Institute for Oral Health University of Rochester, Rochester, NY

    7 shared publications
  • Changyong Feng

    Associate Professor, Department of Biostatistics and Computational Biology, University of Rochester, Rochester, NY

    7 shared publications
  • Carlo Ercoli

    Department of Prosthodontics Eastman Institute for Oral Health University of Rochester Rochester New York USA

    6 shared publications
  • Georgios E. Romanos

    Department of Periodontics and Endodontics, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794, USA

    3 shared publications
  • Heeje Lee

    3 shared publications
  • Konstantinos Chochlidakis

    Department of Prosthodontics Eastman Institute for Oral Health University of Rochester Rochester New York USA

    3 shared publications

Latest Publications

  • A combined analog and digital workflow for retrofitting a monolithic ceramic crown to an existing removable partial denture

    by Sherif Hosney, Maria Gabriela Carranza, Alessandro Geminiani, Carlo Ercoli, Panos Papaspyridakos, Konstantinos Chochlidakis


  • Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling

    by Erna R. Einarsdottir, Alessandro Geminiani, Konstantinos Chochlidakis, Changyong Feng, Alexandra Tsigarida, Carlo Ercoli


  • Top Cited Papers

    Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis

    by Konstantinos M. Chochlidakis, Panos Papaspyridakos, Alessandro Geminiani, Chun-Jung Chen, I. Jung Feng, Carlo Ercoli


  • A Comparative Study of the Incidence of Schneiderian Membrane Perforations during Maxillary Sinus Augmentation with a Sonic Oscillating Handpiece versus a Conventional Turbine Handpiece

    by Alessandro Geminiani, Daniel S. Weitz, Carlo Ercoli, Changyong Feng, Jack G. Caton, Dimitrios E.V. Papadimitriou

    Sonic instruments may reduce perforation rates of the schneiderian membrane during lateral window sinus augmentation procedures. This study compares the incidence of membrane perforations using a sonic handpiece with an oscillating diamond insert versus a turbine handpiece with a conventional rotary diamond stone during lateral window sinus augmentation procedures. A retrospective chart analysis identified all lateral window sinus augmentation procedures done during a defined period. Among these procedures, those performed with a sonic handpiece and an oscillating diamond insert (experimental) and those performed with a conventional turbine and rotary diamond stone (conventional) were selected for this study. Reported occurrences of sinus membrane perforations during preparation of the osteotomy and elevation of the sinus membrane, as well as postoperative complications, were recorded and compared between treatment groups. Ninety-three consecutive patients were identified for a total of 130 sinus augmentation procedures (51 conventional, 79 experimental). Schneiderian membrane perforations were noted during preparation of the lateral window osteotomy in 27.5% of the sinuses in the conventional group and 12.7% of sinuses in the experimental group. During membrane elevation, perforations were noted in 43.1% of the sinuses in the conventional group and 25.3% of sinuses in the experimental group. Both differences in perforation rates were statistically significant (p < .05). There was no statistically significant difference in postoperative complications. In this study, the use of a sonic instrument to prepare the lateral window osteotomy during sinus elevation procedures resulted in a reduced perforation rate of the Schneiderian membrane compared with the conventional turbine instrument.


  • Sonosurgery for atraumatic tooth extraction: A clinical report

    by Dimitrios E.V. Papadimitriou, Alessandro Geminiani, Thomas Zahavi, Carlo Ercoli


    • 29 November 2012
      • Vol. 27  (6) , 1527-33

    Restoration of immediately loaded implants in a minimal number of appointments: a retrospective study of clinical effectiveness.

    by Carlo Ercoli, Alessandro Geminiani, Heeje Lee, Changyong Feng, Carlo E Poggio

    The purpose of this study was to assess the clinical effectiveness of an experimental technique versus the conventional method for the fabrication of implant-supported fixed complete dentures. Between January 2005 and June 2010, edentulous patients who had received rehabilitation by means of nonsegmented fixed implant-supported complete dentures were identified from the pool of individuals treated at Eastman Institute for Oral Health, University of Rochester. Data collection consisted of a chart review and recording of treatment variables in a customized database. Variables of interest included number of implants per patient, time of implant placement, number of appointments required to complete prosthesis fabrication, type of appointments, manufacturing process used for creation of the framework, and fit of the framework. The number of appointments for conventional and experimental protocols was evaluated for statistical significance using two-way analysis of variance. Presence or absence of clinically acceptable prosthesis fit with the two techniques was evaluated using the Fisher exact test and exact logistic regression analysis. Forty-two patients (48 arches) were included. When the experimental technique was used, prosthesis fabrication and delivery required an average of 4 appointments, whereas the conventional technique required an average of 7.8 appointments to deliver the definitive prosthesis. The prostheses fabricated with the experimental technique showed clinically passive fit on the implants in 17 of 18 arches. The frameworks fabricated with the conventional technique achieved clinically passive fit in 18 of 30 arches. The experimental technique significantly reduced the number of appointments required to fabricate a nonsegmented fixed implant-supported prosthesis. Moreover, this experimental technique provided clinically acceptable fit of the prosthesis in a significantly greater number of cases compared to a conventional implant elastomeric impression technique.

  • Thermodynamic effects of laser irradiation of implants placed in bone: an in vitro study

    by Chris Leja, Alessandro Geminiani, Jack Caton, Georgios E. Romanos

    Lasers have been proposed for various applications involving dental implants, including uncovering implants and treating peri-implantitis. However, the effect of laser irradiation on the implant surface temperature is only partially known. The aim of this pilot study was to determine the effect of irradiation with diode, carbon dioxide, and Er:YAG lasers on the surface temperature of dental implants placed in bone, in vitro. For this study, one dental implant was placed in a bovine rib. A trephine bur was used to create a circumferential defect to simulate peri-implantitis, and thermocouples were placed at the coronal and apical aspect of the implant. The implant was irradiated for 60 s using four different lasers independently and change in temperature as well as time to reach a 10 °C increase in temperature were recorded. There was wide variability in results among the lasers and settings. Time for a 10 °C increase ranged from 0.9 to over 60 s for the coronal thermocouple and from 18 to over 60 s for the apical thermocouple. Maximum temperature ranged from 5.9 to 70.9 °C coronally and from 1.4 to 23.4 °C apically. During laser irradiation of dental implants, a surface temperature increase beyond the “critical threshold” of 10 °C can be reached after only 18 s.


  • The Influence of Verification Jig on Framework Fit for Nonsegmented Fixed Implant‐Supported Complete Denture

    by Carlo Ercoli, Alessandro Geminiani, Changyong Feng, Heeje Lee

    Purpose: The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant‐supported full‐arch prosthesis framework is fabricated with or without the aid of a verification jig.Materials and Methods: This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant‐supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try‐in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive.Results: When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001).Conclusions: Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant‐supported complete denture.


  • Clinical Evaluation of Immediate Loading of Electroeroded Screw‐Retained Titanium Fixed Prostheses Supported by Tilted Implant: A Multicenter Retrospective Study

    by Alessandro Acocella, Carlo Ercoli, Alessandro Geminiani, Changyong Feng, Mauro Billi, Gabriele Acocella, Domenico Giannini, Roberto Sacco

    Statement of problem: Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long‐term data available in the literature, when an electroeroded definitive cast‐titanium fixed prosthesis is used for this treatment protocol.Purpose: The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast‐titanium screw‐retained fixed prosthesis.Materials and Methods: Forty‐five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin‐titanium screw‐retained prosthesis fabricated by electroerosion.Results: Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%.Conclusion: Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw‐retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results.