sLASER and PRESS Perform Similarly at Revealing Metabolite-Age Correlations
Preprint
Abstract
Purpose To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate. Methods MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale (CSO) and posterior cingulate cortex (PCC) regions. Acquisition parameters included TR/TE 2000/30 ms; 96 transients; 2048 datapoints sampled at 2 kHz. Spectra were analyzed using Osprey. Signal-to-noise ratio (SNR), full-width-half-maximum linewidth of tCr, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. Results SNR and linewidth were significantly higher (pConclusion The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in CSO and PCC data acquired at 3T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in ‘good’ brain regions at clinical field strength.Keywords
This publication has 46 references indexed in Scilit:
- Longitudinal inter‐ and intra‐individual human brain metabolic quantification over 3 years with proton MR spectroscopy at 3 TMagnetic Resonance in Medicine, 2011
- Test‐retest reliability and reproducibility of short‐echo‐time spectroscopic imaging of human brain at 3TMagnetic Resonance in Medicine, 2011
- If J doesn't evolve, it won't J‐resolve: J‐PRESS with bandwidth‐limited refocusing pulsesMagnetic Resonance in Medicine, 2011
- Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scannersJournal of Magnetic Resonance, 2010
- Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantificationJournal of Magnetic Resonance Imaging, 2009
- Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulsesMagnetic Resonance Materials in Physics, Biology and Medicine, 2008
- Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulsesMagnetic Resonance in Medicine, 2007
- Adiabatic refocusing pulses for volume selection in magnetic resonance spectroscopic imagingMagnetic Resonance in Medicine, 2007
- ShortTE single-voxel1H-MR spectroscopy of hippocampal structures in healthy adults at 1.5 Tesla—how reproducible are the results?NMR in Biomedicine, 2005
- Localized proton MR spectroscopy of the brain in childrenJournal of Magnetic Resonance Imaging, 1993