Automatic interference controller device for eliminating the power-line interference in biopotential signals
Authors:
- A.Y. YamamotoAYA.Y. Yamamoto
- T. NakamuraTNT. Nakamura
- K. KitaokaKKK. Kitaoka
- 7 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10915281) , 1358-1362
Abstract
In high-resolution biopotential measurements, interference from local 60 Hz power-line often disturbs the original signals. The sources and elimination methods of this interference have been considered by many researchers. However, it does not completely eliminate because of many complex factors. We have designed a new method for eliminating the power-line interference by using an automatic interference controller device (AICD). The principle of this method is based on automatically matching of the amplitude and the phase front power-line signal detector of AICD on those of interference of biopotential signal. In this work, we used ECG signal as the biopotential signals source. The device does not make ECG signal distorted and only eliminates the interference signal. Interference elimination can be performed continuously and rapidly, even if the situations of interference are changing with time or frequency in the electrical system. The handling is easy because of the system is automatic, and it is applicable not only to ECG, but also to other biopotential signals.Keywords
This publication has 10 references indexed in Scilit:
- A comprehensive model for power-line interference in biopotential measurements2003
- Simple self-tuned notch filter in a bio-potential amplifierMedical & Biological Engineering & Computing, 1997
- Accuracy of 50 Hz interference subtraction from an electrocardiogramMedical & Biological Engineering & Computing, 1996
- Comparative analysis of power-line interference between two- or three-electrode biopotential amplifiersMedical & Biological Engineering & Computing, 1995
- On the Reduction of Interference Due to Common Mode Voltage in Two-Electrode Biopotential AmplifiersIEEE Transactions on Biomedical Engineering, 1986
- A Learning Filter for Removing Noise InterferenceIEEE Transactions on Biomedical Engineering, 1983
- Driven-right-leg circuit designIEEE Transactions on Biomedical Engineering, 1983
- Reduction of Interference Due to Common Mode Voltage in Biopotential AmplifiersIEEE Transactions on Biomedical Engineering, 1983
- Ground-Free ECG Recording with Two ElectrodesIEEE Transactions on Biomedical Engineering, 1980
- 60-Hz Interference in ElectrocardiographyIEEE Transactions on Biomedical Engineering, 1973