Primary and coupled motions after cervical total disc replacement using a compressible six-degree-of-freedom prosthesis
- 24 September 2010
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 21 (S5) , 618-629
Abstract
This study tested the hypotheses that (1) cervical total disc replacement with a compressible, six-degree-of-freedom prosthesis would allow restoration of physiologic range and quality of motion, and (2) the kinematic response would not be adversely affected by variability in prosthesis position in the sagittal plane. Twelve human cadaveric cervical spines were tested. Prostheses were implanted at C5–C6. Range of motion (ROM) was measured in flexion–extension, lateral bending, and axial rotation under ±1.5 Nm moments. Motion coupling between axial rotation and lateral bending was calculated. Stiffness in the high flexibility zone was evaluated in all three testing modes, while the center of rotation (COR) was calculated using digital video fluoroscopic images in flexion–extension. Implantation in the middle position increased ROM in flexion–extension from 13.5 ± 2.3 to 15.7 ± 3.0° (p < 0.05), decreased axial rotation from 9.9 ± 1.7 to 8.3 ± 1.6° (p < 0.05), and decreased lateral bending from 8.0 ± 2.1 to 4.5 ± 1.1° (p < 0.05). Coupled lateral bending decreased from 0.62 ± 0.16 to 0.39 ± 0.15° for each degree of axial rotation (p < 0.05). Flexion–extension stiffness of the reconstructed segment with the prosthesis in the middle position did not deviate significantly from intact controls, whereas the lateral bending and axial rotation stiffness values were significantly larger than intact. Implanting the prosthesis in the posterior position as compared to the middle position did not significantly affect the ROM, motion coupling, or stiffness of the reconstructed segment; however, the COR location better approximated intact controls with the prosthesis midline located within ±1 mm of the disc-space midline. Overall, the kinematic response after reconstruction with the compressible, six-degree-of-freedom prosthesis within ±1 mm of the disc-space midline approximated the intact response in flexion–extension. Clinical studies are needed to understand and interpret the effects of limited restoration of lateral bending and axial rotation motions and motion coupling on clinical outcome.Keywords
This publication has 56 references indexed in Scilit:
- Kinematics of Cervical Total Disc Replacement Adjacent to a Two-Level, Straight Versus Lordotic FusionSpine, 2011
- Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplastyEuropean Spine Journal, 2009
- Update on cervical disc arthroplasty: where are we and where are we going?Current Reviews in Musculoskeletal Medicine, 2008
- Cervical Spine Arthroplasty BiomechanicsNeurosurgery Clinics of North America, 2005
- Load-displacement properties of the normal and injured lower cervical spine in vitroEuropean Spine Journal, 2000
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998
- Stability Increase of the Lumbar Spine With Different Muscle GroupsSpine, 1995
- Load-displacement properties of lower cervical spine motion segmentsJournal of Biomechanics, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- An in-vitro study of the kinematics of the normal, injured and stabilized cervical spineJournal of Biomechanics, 1984