Printed soft skin electrodes for seamless bio-impedance measurements
Open Access
- 1 March 2023
- journal article
- research article
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 8 (1) , 015020
Abstract
Bio-impedance measurements are widely used to assess various physiological parameters. Contemporary skin electrodes for bio-impedance measurements are cumbersome and novel electrode designs are needed to allow fast and easy placement, long-term stability and user comfort. This investigation introduces dry, printed, bio-compatible electrode arrays, made of screen-printed carbon and inkjet-printed PEDOT:PSS that measure bio-impedance non-invasively and stably. Two contact impedance measurements yield the lowest normalized values of soft electrodes reported to date. Four contact bio-impedance measurements from the radial, ulnar, common carotid and superficial temporal arteries were performed, demonstrating the ability to capture blood pulsation in different areas with small form factor. Owing to the unique properties of the printed electrodes reported here, we were able to demonstrate for the first time blood pulsation in the face, continuous blood pulsation measurement during simultaneous muscle activation and signal stability over many hours.Keywords
Funding Information
- Ministry of Culture and Sport
- Deutsche Forschungsgemeinschaft (HE 7056/4-1)
This publication has 41 references indexed in Scilit:
- Monitoring heart and respiratory rates at radial artery based on PPGOptik, 2013
- Correction: Getting a Grip on Memory: Unilateral Hand Clenching Alters Episodic RecallPLOS ONE, 2013
- Inkjet-printed graphene-PEDOT:PSS modified screen printed carbon electrode for biochemical sensingJournal of Materials Chemistry, 2012
- Mechanical flexibility of transparent PEDOT:PSS electrodes prepared by gravure printing for flexible organic solar cellsSolar Energy Materials and Solar Cells, 2011
- Wearable electrochemical sensors for in situ analysis in marine environmentsThe Analyst, 2011
- Comparison of cerebral activity during teeth clenching and fist clenching: a functional magnetic resonance imaging studyEuropean Journal of Oral Sciences, 2010
- Electrical characterization of PEDOT:PSS beyond humidity saturationSensors and Actuators B: Chemical, 2009
- Facial Movement, Breathing, Temperature, and Affect: Implications of the Vascular Theory of Emotional EfferenceCognition and Emotion, 1997
- Facial feedback hypotheses: Evidence, implications, and directionsMotivation and Emotion, 1996
- MORTALITY IN DIABETIC AUTONOMIC NEUROPATHYThe Lancet, 1976