BLBara Levit

Bara Levit

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bara Levit has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Soft electrodes for simultaneous bio-potential and bio-impedance study of the face

    by Bara Levit, Paul F Funk, Yael Hanein

    The human body’s vascular system is a finely regulated network: blood vessels can change in shape (i.e. constrict, or dilate), their elastic response may shift and they may undergo temporary and partial blockages due to pressure applied by skeletal muscles in their immediate vicinity. Simultaneous measurement of muscle activation and the corresponding changes in vessel diameter, in particular at anatomical regions such as the face, is challenging, and how muscle activation constricts blood vessels has been experimentally largely overlooked. Here we report on a new electronic skin technology for facial investigations to address this challenge. The technology consists of screen-printed dry carbon electrodes on soft polyurethane substrate. Two dry electrode arrays were placed on the face: One array for bio-potential measurements to capture muscle activity and a second array for bio-impedance. For the bio-potential signals, independent component analysis (ICA) was used to differentiate different muscle activations. Four-contact bio-impedance measurements were used to extract changes (related to artery volume change), as well as beats per minute (BPM). We performed concurrent bio-potential and bio-impedance measurements in the face. From the simultaneous measurements we successfully captured fluctuations in the superficial temporal artery diameter in response to facial muscle activity, which ultimately changes blood flow. The observed changes in the face, following muscle activation, were consistent with measurements in the forearm and were found to be notably more intricate. Both at the arm and the face, a clear increase in the baseline impedance was recorded during muscle activation (artery narrowing), while the impedance changes signifying the pulse had a clear repetitive trend only at the forearm. These results reveal the direct connection between muscle activation and the blood vessels in their vicinity and start to unveil the complex mechanisms through which facial muscles might modulate blood flow and possibly affect human physiology.


  • Open Access

    Bio-potential noise of dry printed electrodes: physiology versus the skin-electrode impedance

    by Ana Arché-Núñez, Peter Krebsbach, Bara Levit, Daniel Possti, Aaron Gerston, Thorsten Knoll, Thomas Velten, Chen Bar-Haim, Shani Oz, Shira Klorfeld-Auslender, et al.

    Objective . To explore noise characteristics and the effect physiological activity has on the link between impedance and noise. Approach . Dry-printed electrodes are emerging as a new and exciting technology for skin electro-physiology. Such electrode arrays offer many advantages including user convenience, quick placement, and high resolution. Here we analyze extensive electro-physiological data recorded from the arm and the face to study and quantify the noise of dry electrodes, and to characterize the link between noise and impedance. In particular, we studied the effect of the physiological state of the subject (e.g. rapid eye movement sleep) on noise. Main results . We show that baseline noise values extracted from dry electrodes in the arm are in agreement with the Nyquist equation. In the face, on the other hand, the measured noise values were higher than the values predicted by the Nyquist equation. In addition, we studied how different electrode properties affect performances, including electrode size, shape, and material properties. Significance . Altogether, the results presented here provide a basis for understanding dry electrode performances and substantiate their great potential in electro-physiological investigations.


  • Open Access

    Wearable facial electromyography: in the face of new opportunities

    by Bara Levit, Shira Klorfeld-Auslender, Yael Hanein

    Facial muscles play an important role in a vast range of physiological functions, ranging from mastication to communication. Any disruption in their normal function may lead to serious negative effects on human well-being. A very wide range of medical disorders and conditions in psychology, neurology, psychiatry, and cosmetic surgery are related to facial muscles, and scientific explorations spanning over decades exposed many fascinating phenomena. For example, expansive evidence implicates facial muscle activation with the expression of emotions. Yet, the exact manner by which emotions are expressed is still debated: whether facial expressions are universal, how gender and cultural differences shape facial expressions and if and how facial muscle activation shape the internal emotional state. Surface electromyography (EMG) is one of the best tools for direct investigation of facial muscle activity and can be applied for medical and research purposes. The use of surface EMG has been so far restricted, owing to limited resolution and cumbersome setups. Current technologies are inconvenient, interfere with the subject normal behavior, and require know-how in proper electrode placement. High density electrode arrays based on soft skin technology is a recent development in the realm of surface EMG. It opens the door to perform facial EMG (fEMG) with high signal quality, while maintaining significantly more natural environmental conditions and higher data resolution. Signal analysis of multi-electrode recordings can also reduce crosstalk to achieve single muscle resolution. This perspective paper presents and discusses new opportunities in mapping facial muscle activation, brought about by this technological advancement. The paper briefly reviews some of the main applications of fEMG and presents how these applications can benefit from a more precise and less intrusive technology.


  • Open Access

    Printed soft skin electrodes for seamless bio-impedance measurements

    by Bara Levit, Peter Krebsbach, Chen Bar-Haim, Gerardo Hernandez-Sosa, Yael Hanein

    Bio-impedance measurements are widely used to assess various physiological parameters. Contemporary skin electrodes for bio-impedance measurements are cumbersome and novel electrode designs are needed to allow fast and easy placement, long-term stability and user comfort. This investigation introduces dry, printed, bio-compatible electrode arrays, made of screen-printed carbon and inkjet-printed PEDOT:PSS that measure bio-impedance non-invasively and stably. Two contact impedance measurements yield the lowest normalized values of soft electrodes reported to date. Four contact bio-impedance measurements from the radial, ulnar, common carotid and superficial temporal arteries were performed, demonstrating the ability to capture blood pulsation in different areas with small form factor. Owing to the unique properties of the printed electrodes reported here, we were able to demonstrate for the first time blood pulsation in the face, continuous blood pulsation measurement during simultaneous muscle activation and signal stability over many hours.