Comparison of Visual Outcome After Hyperopic LASIK Using a Wavefront-Optimized Platform Versus Other Excimer Lasers in the Past Two Decades
Open Access
- 19 May 2021
- journal article
- research article
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 10 (3) , 547-563
Abstract
Introduction Laser-assisted in-situ keratomileusis (LASIK) for the correction of hyperopia and hyperopic astigmatism is challenging and has been less studied than for the correction of myopia and myopic astigmatism. The aim of this study was to analyze the refractive outcomes of LASIK in hyperopia and hyperopic astigmatic eyes using a wave-front optimized laser platform (the Allegretto EX500 laser) and perform a historical comparison with other excimer lasers within the past two decades. Methods A one-center (Tertiary Refractive Center, Draper, Utah), retrospective, non-comparative study was conducted on 379 eyes treated with LASIK for hyperopia and hyperopic astigmatism. The data retrieved on these eyes were analyzed using uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and spherical equivalents. A literature search of excimer platforms in use in the past 20 years and a comparison of US Federal Drug Administration-approved platforms for hyperopia were performed. Results At 3 and 12 months postoperatively, 142 (66%) and 81 (69%) eyes had a UDVA of 20/20 or better and 207 (96%) and 114 (97%) eyes had a UDVA of 20/40 or better, respectively. The mean refractive spherical equivalent was − 0.52 ± 0.78 D at 3 months and − 0.46 ± 0.79 D at 12 months. At 12 months, 181 (96%) eyes achieved a spherical equivalent within ± 1.00 D of the intended target. Studies published before 2005 reported lower rates of UDVA 20/20 or better (32%) compared to those published after (68%); however, this discrepancy was less evident for UDVA 20/40 or better. A similar trend towards improved accuracy was noted in the literature with postoperative manifest refractive spherical equivalent within ± 0.50 D before and after 2005. Conclusion There has been significant improvement in safety, efficacy, stability, and accuracy of LASIK treatment for hyperopia and hyperopic astigmatism within the past two decades. Newer excimer lasers meet industry standards and in particular, the Allegretto EX500 used in this study exceeded industry standards.Keywords
This publication has 30 references indexed in Scilit:
- Three-Year Follow-up of Hyperopic LASIK Using a 500-Hz Excimer Laser SystemJournal of Refractive Surgery, 2015
- Laser in situ keratomileusis for high hyperopia (>5.0 diopters) using optimized aspheric profiles: Efficacy and safetyJournal of Cataract & Refractive Surgery, 2013
- Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platformClinical Ophthalmology, 2012
- Six-month clinical outcomes after hyperopic correction with the SCHWIND AMARIS Total-Tech laserJournal of Optometry, 2010
- Hyperopic LASIK With Esiris/Schwind TechnologyJournal of Refractive Surgery, 2006
- 5-year follow-up of LASIK for hyperopiaOphthalmology, 2005
- Hyperopic Laser In Situ KeratomileusisCornea, 2001
- Results of laser in situ keratomileusis in hyperopic compound astigmatismJournal of Cataract & Refractive Surgery, 1999
- Laser in situ keratomileusis for hyperopiaJournal of Cataract & Refractive Surgery, 1998
- A new method of analyzing vectors for changes in astigmatismJournal of Cataract & Refractive Surgery, 1993