William B. West
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William B. West has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Majid Moshirfar
Hoopes Moshirfar Research Center, Hoopes Vision, Draper, UT
4 shared publications - Phillip C. Hoopes
Hoopes Moshirfar Research Center, Hoopes Vision, Draper, UT
4 shared publications - Shannon E. McCabe
Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA
3 shared publications - Yasmyne Castillo Ronquillo
Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA
3 shared publications Robert J Thomson
McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, TX, USA
2 shared publicationsAdam Lewis
Kansas City University College of Osteopathic Medicine, Kansas City, MO, USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 191-195
Comparison of Phacoemulsification Grooving Efficiency in Longitudinal vs Transversal Handpieces
Purpose: To determine the difference, if any, in grooving efficiency at various settings on the Whitestar Signature Pro phacoemulsification (phaco) system. Methods: Cataractous lenses were simulated by exposing porcine lenses to formalin for 2 hours. A total of 120 lenses were analyzed at various power settings on both longitudinal and transversal handpieces. Twenty trials each were performed with power set to 25%, 50%, and 75% on both handpieces. A Whitestar Phaco Handpiece System was used to provide longitudinal power, and a Whitestar Signature Ellipsis Handpiece provided transversal power. Lenses were placed within a plastic chamber and grooved by an investigator blinded to settings. A second investigator recorded times and adjusted settings. The Whitestar Signature Pro phaco system was used for grooving. Results: There was no significant difference in grooving times between the longitudinal and transverse handpieces at any power setting (P > 0.05). There was a significant decrease in grooving times when comparing the 25% power setting with the 75% power setting for the transversal handpiece (P=0.021). Conclusion: Both longitudinal and transversal handpieces on the Whitestar Signature Pro phaco system produce similar results to one another at each power setting. There is a general trend toward shorter grooving times, reflecting greater efficiency, at higher power settings. Grooving efficiency on the transversal handpiece may be more affected by changes in the power settings as compared with the longitudinal settings.
- 1 January 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 191-195
Open AccessComparison of Phacoemulsification Grooving Efficiency in Longitudinal vs Transversal Handpieces
Purpose: To determine the difference, if any, in grooving efficiency at various settings on the Whitestar Signature Pro phacoemulsification (phaco) system. Methods: Cataractous lenses were simulated by exposing porcine lenses to formalin for 2 hours. A total of 120 lenses were analyzed at various power settings on both longitudinal and transversal handpieces. Twenty trials each were performed with power set to 25%, 50%, and 75% on both handpieces. A Whitestar Phaco Handpiece System was used to provide longitudinal power, and a Whitestar Signature Ellipsis Handpiece provided transversal power. Lenses were placed within a plastic chamber and grooved by an investigator blinded to settings. A second investigator recorded times and adjusted settings. The Whitestar Signature Pro phaco system was used for grooving. Results: There was no significant difference in grooving times between the longitudinal and transverse handpieces at any power setting (P > 0.05). There was a significant decrease in grooving times when comparing the 25% power setting with the 75% power setting for the transversal handpiece (P=0.021). Conclusion: Both longitudinal and transversal handpieces on the Whitestar Signature Pro phaco system produce similar results to one another at each power setting. There is a general trend toward shorter grooving times, reflecting greater efficiency, at higher power settings. Grooving efficiency on the transversal handpiece may be more affected by changes in the power settings as compared with the longitudinal settings.
- Open Access
- 1 July 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 3051-3063
Comparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens
Purpose: To compare the visual performance of the AcrySof IQ PanOptix trifocal intraocular lens and the TECNIS Symfony extended depth-of-focus lens at near and distance visual ranges. Methods: A total of 146 patients (221 eyes) who underwent phacoemulsification and cataract extraction and received either a PanOptix or Symfony lens from January 2019 to July 2020 were included in the study (83 PanOptix non-toric, 30 PanOptix toric, 70 Symfony non-toric, and 38 Symfony toric). Uncorrected distance (UDVA), uncorrected near (UNVA), and corrected distance (CDVA) visual acuity were assessed at one-day, one-month, and three-months postoperatively. Averages of UDVA, UNVA, and CDVA were taken to evaluate which lens was superior at near and distance visual ranges. Secondary outcome measures including glare, halo, dryness, and problems with night vision were documented at each postoperative visit. Results: At one month postoperatively, the average UNVA was 0.16 ± 0.14 logMAR in the PanOptix group and 0.21 ± 0.14 logMAR in the Symfony group (P=0.007); the average UDVA for the PanOptix group was 0.09 ± 0.13 logMAR compared to the Symfony group at 0.10 ± 0.14 logMAR (P=0.67); and the average CDVA was 0.02 ± 0.05 logMAR in the PanOptix group and 0.00 ± 0.04 logMAR in the Symfony group (P=0.11). At three months postoperatively, there were no statistically significant differences in UNVA, UDVA, or CDVA between the two groups (P=0.18, 0.79, 0.68 respectively). There was no statistically significant difference in secondary outcome measures at one- and three-months (P=0.49, 0.10 respectively). Conclusion: The AcrySof IQ PanOptix trifocal intraocular lens appears to afford better UNVA compared to the TECNIS Symfony extended depth-of-focus intraocular lens at one-month postoperatively, though this difference was not seen at three months postoperatively. There is no statistically significant difference in UDVA and CDVA between the two groups at postoperative day one, one-month, and three-months.
- 1 July 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 3051-3063
Open AccessComparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens
Purpose: To compare the visual performance of the AcrySof IQ PanOptix trifocal intraocular lens and the TECNIS Symfony extended depth-of-focus lens at near and distance visual ranges. Methods: A total of 146 patients (221 eyes) who underwent phacoemulsification and cataract extraction and received either a PanOptix or Symfony lens from January 2019 to July 2020 were included in the study (83 PanOptix non-toric, 30 PanOptix toric, 70 Symfony non-toric, and 38 Symfony toric). Uncorrected distance (UDVA), uncorrected near (UNVA), and corrected distance (CDVA) visual acuity were assessed at one-day, one-month, and three-months postoperatively. Averages of UDVA, UNVA, and CDVA were taken to evaluate which lens was superior at near and distance visual ranges. Secondary outcome measures including glare, halo, dryness, and problems with night vision were documented at each postoperative visit. Results: At one month postoperatively, the average UNVA was 0.16 ± 0.14 logMAR in the PanOptix group and 0.21 ± 0.14 logMAR in the Symfony group (P=0.007); the average UDVA for the PanOptix group was 0.09 ± 0.13 logMAR compared to the Symfony group at 0.10 ± 0.14 logMAR (P=0.67); and the average CDVA was 0.02 ± 0.05 logMAR in the PanOptix group and 0.00 ± 0.04 logMAR in the Symfony group (P=0.11). At three months postoperatively, there were no statistically significant differences in UNVA, UDVA, or CDVA between the two groups (P=0.18, 0.79, 0.68 respectively). There was no statistically significant difference in secondary outcome measures at one- and three-months (P=0.49, 0.10 respectively). Conclusion: The AcrySof IQ PanOptix trifocal intraocular lens appears to afford better UNVA compared to the TECNIS Symfony extended depth-of-focus intraocular lens at one-month postoperatively, though this difference was not seen at three months postoperatively. There is no statistically significant difference in UDVA and CDVA between the two groups at postoperative day one, one-month, and three-months.
- Open Access
- 19 May 2021
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 10 (3) , 547-563
Comparison of Visual Outcome After Hyperopic LASIK Using a Wavefront-Optimized Platform Versus Other Excimer Lasers in the Past Two Decades
Introduction Laser-assisted in-situ keratomileusis (LASIK) for the correction of hyperopia and hyperopic astigmatism is challenging and has been less studied than for the correction of myopia and myopic astigmatism. The aim of this study was to analyze the refractive outcomes of LASIK in hyperopia and hyperopic astigmatic eyes using a wave-front optimized laser platform (the Allegretto EX500 laser) and perform a historical comparison with other excimer lasers within the past two decades. Methods A one-center (Tertiary Refractive Center, Draper, Utah), retrospective, non-comparative study was conducted on 379 eyes treated with LASIK for hyperopia and hyperopic astigmatism. The data retrieved on these eyes were analyzed using uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and spherical equivalents. A literature search of excimer platforms in use in the past 20 years and a comparison of US Federal Drug Administration-approved platforms for hyperopia were performed. Results At 3 and 12 months postoperatively, 142 (66%) and 81 (69%) eyes had a UDVA of 20/20 or better and 207 (96%) and 114 (97%) eyes had a UDVA of 20/40 or better, respectively. The mean refractive spherical equivalent was − 0.52 ± 0.78 D at 3 months and − 0.46 ± 0.79 D at 12 months. At 12 months, 181 (96%) eyes achieved a spherical equivalent within ± 1.00 D of the intended target. Studies published before 2005 reported lower rates of UDVA 20/20 or better (32%) compared to those published after (68%); however, this discrepancy was less evident for UDVA 20/40 or better. A similar trend towards improved accuracy was noted in the literature with postoperative manifest refractive spherical equivalent within ± 0.50 D before and after 2005. Conclusion There has been significant improvement in safety, efficacy, stability, and accuracy of LASIK treatment for hyperopia and hyperopic astigmatism within the past two decades. Newer excimer lasers meet industry standards and in particular, the Allegretto EX500 used in this study exceeded industry standards.
- 19 May 2021
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 10 (3) , 547-563
Open AccessComparison of Visual Outcome After Hyperopic LASIK Using a Wavefront-Optimized Platform Versus Other Excimer Lasers in the Past Two Decades
Introduction Laser-assisted in-situ keratomileusis (LASIK) for the correction of hyperopia and hyperopic astigmatism is challenging and has been less studied than for the correction of myopia and myopic astigmatism. The aim of this study was to analyze the refractive outcomes of LASIK in hyperopia and hyperopic astigmatic eyes using a wave-front optimized laser platform (the Allegretto EX500 laser) and perform a historical comparison with other excimer lasers within the past two decades. Methods A one-center (Tertiary Refractive Center, Draper, Utah), retrospective, non-comparative study was conducted on 379 eyes treated with LASIK for hyperopia and hyperopic astigmatism. The data retrieved on these eyes were analyzed using uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and spherical equivalents. A literature search of excimer platforms in use in the past 20 years and a comparison of US Federal Drug Administration-approved platforms for hyperopia were performed. Results At 3 and 12 months postoperatively, 142 (66%) and 81 (69%) eyes had a UDVA of 20/20 or better and 207 (96%) and 114 (97%) eyes had a UDVA of 20/40 or better, respectively. The mean refractive spherical equivalent was − 0.52 ± 0.78 D at 3 months and − 0.46 ± 0.79 D at 12 months. At 12 months, 181 (96%) eyes achieved a spherical equivalent within ± 1.00 D of the intended target. Studies published before 2005 reported lower rates of UDVA 20/20 or better (32%) compared to those published after (68%); however, this discrepancy was less evident for UDVA 20/40 or better. A similar trend towards improved accuracy was noted in the literature with postoperative manifest refractive spherical equivalent within ± 0.50 D before and after 2005. Conclusion There has been significant improvement in safety, efficacy, stability, and accuracy of LASIK treatment for hyperopia and hyperopic astigmatism within the past two decades. Newer excimer lasers meet industry standards and in particular, the Allegretto EX500 used in this study exceeded industry standards.
- Open Access
- 1 December 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 4337-4346
Visual Outcomes After Sequential Posterior Chamber Phakic IOL with Corneal Refractive Surgery (Bioptics) for the Treatment of Myopic Astigmatism
Purpose: To report the outcomes of sequential posterior chamber phakic intraocular lens (PC-pIOL) with corneal refractive surgery in conventional (PC-pIOL prior to refractive surgery) and reverse (refractive surgery prior to PC-pIOL) bioptics for treating high myopic astigmatism. Setting: Tertiary refractive center, Draper, Utah, USA. Design: Retrospective case series. Methods: Medical records of patients who underwent planned bioptics were reviewed. Surgery involved PC-pIOL placement using an implantable collamer lens (ICL) with preceding or subsequent LASIK or PRK. Pre- and postoperative manifest spherical equivalent (SEQ), visual acuity, and PC-pIOL vault were analyzed. Results: Of the 51 eyes present at 12 months postoperatively, 49 eyes (96%) achieved target SEQ within ± 1.00 D and an identical amount achieved refractive astigmatism ≤ 1.00 D. Post-bioptics eyes achieved a postoperative UDVA equal to or better than preoperative CDVA in 45 eyes (88%). Efficacy and safety indices were 1.08 ± 0.20 (41 eyes) and 1.13 ± 0.22 (44 eyes) for conventional bioptics and 0.99 ± 0.42 (7 eyes) and 1.15 ± 0.38 (7 eyes) for reverse bioptics eyes at 12 months. The maximum PC-pIOL vault of conventional bioptics eyes (27 eyes) within 6 months before and after LASIK/PRK was 385 ± 159 μm and 377 ± 135 μm, respectively (P = 0.71). Conclusion: Bioptics for high myopic astigmatism was safe and effective. Reverse bioptics, although not as traditional, could provide similar results. Additionally, the PC-pIOL vault does not appear to be affected by LASIK/PRK.
- 1 December 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 4337-4346
Open AccessVisual Outcomes After Sequential Posterior Chamber Phakic IOL with Corneal Refractive Surgery (Bioptics) for the Treatment of Myopic Astigmatism
Purpose: To report the outcomes of sequential posterior chamber phakic intraocular lens (PC-pIOL) with corneal refractive surgery in conventional (PC-pIOL prior to refractive surgery) and reverse (refractive surgery prior to PC-pIOL) bioptics for treating high myopic astigmatism. Setting: Tertiary refractive center, Draper, Utah, USA. Design: Retrospective case series. Methods: Medical records of patients who underwent planned bioptics were reviewed. Surgery involved PC-pIOL placement using an implantable collamer lens (ICL) with preceding or subsequent LASIK or PRK. Pre- and postoperative manifest spherical equivalent (SEQ), visual acuity, and PC-pIOL vault were analyzed. Results: Of the 51 eyes present at 12 months postoperatively, 49 eyes (96%) achieved target SEQ within ± 1.00 D and an identical amount achieved refractive astigmatism ≤ 1.00 D. Post-bioptics eyes achieved a postoperative UDVA equal to or better than preoperative CDVA in 45 eyes (88%). Efficacy and safety indices were 1.08 ± 0.20 (41 eyes) and 1.13 ± 0.22 (44 eyes) for conventional bioptics and 0.99 ± 0.42 (7 eyes) and 1.15 ± 0.38 (7 eyes) for reverse bioptics eyes at 12 months. The maximum PC-pIOL vault of conventional bioptics eyes (27 eyes) within 6 months before and after LASIK/PRK was 385 ± 159 μm and 377 ± 135 μm, respectively (P = 0.71). Conclusion: Bioptics for high myopic astigmatism was safe and effective. Reverse bioptics, although not as traditional, could provide similar results. Additionally, the PC-pIOL vault does not appear to be affected by LASIK/PRK.
- Open Access
- 1 October 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3551-3562
Initial Single-Site Experience Using SMILE for the Treatment of Astigmatism in Myopic Eyes and Comparison of Astigmatic Outcomes with Existing Literature
Purpose: To assess a single site’s initial experience with SMILE for the treatment of myopic astigmatism and compare outcomes and vector analysis results with the US Food and Drug Administration (FDA) results and published literature. Patients and Methods: Forty-eight eyes (29 patients) with mean preoperative sphere of − 5.11 ± 1.31 diopters (D) and cylinder of − 1.12 ± 0.60 D underwent SMILE. Visual acuity, refractive, and vector analysis outcomes as well as subjective measures were reported at three and twelve months postoperatively and compared with FDA results and the published literature between 2014 and 2020 involving treatment of patients with mean cylinders of >− 0.50 to ≤− 3.00 D. Results: At three and twelve months, 43 and 32 eyes were evaluated, respectively. At twelve months, mean cylinder power was reduced to − 0.38 ± 0.38 D with 78.1% achieving ≤± 0.50 D. Uncorrected distance visual acuity (UDVA) ≥ 20/20 was achieved in 77.4% of eyes by twelve months with 100% achieving ≥ 20/30 UDVA. No loss of corrected distance visual acuity was observed in eyes seen at twelve months. Correction index (CI) at twelve months was 0.90 indicating overall undercorrection of 10%. Twelve-month CI was 0.96, 0.90, and 0.83 in eyes with preoperative cylinders of <− 1.00 D, ≥− 1.00 to <− 2.00 D, and ≥− 2.00 D, respectively. Mean angle of error was − 1.58 ± 11.61° ranging from − 24.22° to 37.75°. Conclusion: We found SMILE to be an effective and safe means of achieving spectacle independence and improving visual acuity in patients with myopic astigmatism. SMILE has the potential for improved clinical outcomes with better nomogram guidance and advancements in technique. However, surgeons must be aware of the potential for undercorrection in with-the-rule astigmatism and at higher preoperative cylinders and as well as the potential for overcorrection in against-the-rule and lower preoperative cylinder astigmatism.
- 1 October 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3551-3562
Open AccessInitial Single-Site Experience Using SMILE for the Treatment of Astigmatism in Myopic Eyes and Comparison of Astigmatic Outcomes with Existing Literature
Purpose: To assess a single site’s initial experience with SMILE for the treatment of myopic astigmatism and compare outcomes and vector analysis results with the US Food and Drug Administration (FDA) results and published literature. Patients and Methods: Forty-eight eyes (29 patients) with mean preoperative sphere of − 5.11 ± 1.31 diopters (D) and cylinder of − 1.12 ± 0.60 D underwent SMILE. Visual acuity, refractive, and vector analysis outcomes as well as subjective measures were reported at three and twelve months postoperatively and compared with FDA results and the published literature between 2014 and 2020 involving treatment of patients with mean cylinders of >− 0.50 to ≤− 3.00 D. Results: At three and twelve months, 43 and 32 eyes were evaluated, respectively. At twelve months, mean cylinder power was reduced to − 0.38 ± 0.38 D with 78.1% achieving ≤± 0.50 D. Uncorrected distance visual acuity (UDVA) ≥ 20/20 was achieved in 77.4% of eyes by twelve months with 100% achieving ≥ 20/30 UDVA. No loss of corrected distance visual acuity was observed in eyes seen at twelve months. Correction index (CI) at twelve months was 0.90 indicating overall undercorrection of 10%. Twelve-month CI was 0.96, 0.90, and 0.83 in eyes with preoperative cylinders of <− 1.00 D, ≥− 1.00 to <− 2.00 D, and ≥− 2.00 D, respectively. Mean angle of error was − 1.58 ± 11.61° ranging from − 24.22° to 37.75°. Conclusion: We found SMILE to be an effective and safe means of achieving spectacle independence and improving visual acuity in patients with myopic astigmatism. SMILE has the potential for improved clinical outcomes with better nomogram guidance and advancements in technique. However, surgeons must be aware of the potential for undercorrection in with-the-rule astigmatism and at higher preoperative cylinders and as well as the potential for overcorrection in against-the-rule and lower preoperative cylinder astigmatism.