Dropping of an EndoButton into the knee joint 2 years after anterior cruciate ligament repair using proximal fixation methods
- 1 July 2004
- journal article
- case report
- Published by Wiley in Arthroscopy
- Vol. 20 (6) , 641-643
Abstract
One of the most discussed subjects regarding anterior cruciate ligament (ACL) repair methods is femoral fixation. One of the materials often used for fixation in recent years is the EndoButton (Acufex Microsurgical, Mansfield, MA), which provides rapid and secure fixation. Although many reports about femoral fixation with EndoButton have been published, insufficient information is available on possible complications. We have used 240 EndoButtons in our clinic for ACL repairs since 1997. The goal of this study was to report a case of ACL repair with an EndoButton, in which we experienced a complication. In this case, the EndoButton dropped into the knee joint after 2 years.Keywords
This publication has 9 references indexed in Scilit:
- An unidentified pitfall of Endobutton use: case reportKnee Surgery, Sports Traumatology, Arthroscopy, 2002
- EndoButton drill bit failureArthroscopy, 2002
- Tunnel expansion after hamstring anterior cruciate ligament reconstruction with 1‐incision EndoButton femoral fixationArthroscopy, 2000
- Tripled semitendinosus anterior cruciate ligament reconstruction with Endobutton fixation: A 2-3-year follow-up study of 35 patientsActa Orthopaedica, 2000
- Case Report Intra‐articular Detachment of the Endobutton More Than 18 Months After Anterior Cruciate Ligament ReconstructionArthroscopy, 1999
- Potential pitfall of the EndoButtonArthroscopy, 1998
- Arthroscopic posterior cruciate ligament reconstruction using hamstring tendons: One‐incision technique with EndobuttonArthroscopy, 1996
- Endobutton button endoscopie fixation technique in anterior cruciate ligament reconstructionArthroscopy, 1995
- Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction: Brief reportArthroscopy, 1989