Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)
- 24 September 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (5) , 2048-2056
Abstract
A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 ~ 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 \thinspace766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.Keywords
This publication has 25 references indexed in Scilit:
- Design and evaluation of the MAMMI dedicated breast PETMedical Physics, 2012
- Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PETJournal of Oncology, 2012
- Initial clinical test of a breast-PET scannerJournal of Medical Imaging and Radiation Oncology, 2011
- Clinical Imaging Characteristics of the Positron Emission Mammography Camera: PEM Flex Solo IIJournal of Nuclear Medicine, 2009
- Initial Characterization of a Dedicated Breast PET/CT Scanner During Human ImagingJournal of Nuclear Medicine, 2009
- Comparison between positron emission tomography using 2-[fluorine-18]fluoro-2-deoxy-D-glucose, conventional imaging and computed tomography for staging of breast cancerAnnals of Oncology, 2008
- 18F-2-Fluoro-2-Deoxy-d-Glucose Positron Emission Tomography in Staging of Locally Advanced Breast CancerJournal of Clinical Oncology, 2004
- Performance evaluation of the microPET P4: a PET system dedicated to animal imagingPhysics in Medicine & Biology, 2001
- MicroPET: a high resolution PET scanner for imaging small animalsIEEE Transactions on Nuclear Science, 1997
- Exact and approximate rebinning algorithms for 3-D PET dataIEEE Transactions on Medical Imaging, 1997