Pei Chai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pei Chai has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
- Long Wei
Chinese Academy of Sciences
10 shared publications - Baoci Shan
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China; School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, China
7 shared publications - Ming-Kai Yun
Capital Medical University
6 shared publications - Shuangquan Liu
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
6 shared publications - Yingjie Wang
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
5 shared publications - Lin Li
School of Nano Technology and Nano Bionics, University of Science and Technology of China, Hefei, China
4 shared publications
Latest Publications
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1063-1066
Intelligent monitoring system for danger sources of infrastructure construction site based on deep learning
To master the real-time security status of the infrastructure construction site, an intelligent monitoring system for the recognition of the danger sources at infrastructure construction site, which is based on the theory of depth learning, is proposed. The monitoring system mainly includes signal acquisition equipment, internal optical network, server control center and display terminal. The intelligent identification algorithm of the danger sources is the core of the entire system. The characteristics from the image signal are extracted by the sparse self-coding, which is used to train the neural network. Then, the convolution is proposed to reduce the dimensionality of the features. The experiments confirm that the identification algorithm based on deep learning illustrates high accuracy in hazard identification. In terms of feedback, the identification results will be transmitted to the display terminal, and the safety status of the entire infrastructure construction site can be fully controlled to ensure the safety of both the infrastructure site and the power system.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1063-1066
Intelligent monitoring system for danger sources of infrastructure construction site based on deep learning
To master the real-time security status of the infrastructure construction site, an intelligent monitoring system for the recognition of the danger sources at infrastructure construction site, which is based on the theory of depth learning, is proposed. The monitoring system mainly includes signal acquisition equipment, internal optical network, server control center and display terminal. The intelligent identification algorithm of the danger sources is the core of the entire system. The characteristics from the image signal are extracted by the sparse self-coding, which is used to train the neural network. Then, the convolution is proposed to reduce the dimensionality of the features. The experiments confirm that the identification algorithm based on deep learning illustrates high accuracy in hazard identification. In terms of feedback, the identification results will be transmitted to the display terminal, and the safety status of the entire infrastructure construction site can be fully controlled to ensure the safety of both the infrastructure site and the power system.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2461-2464
Research on Intelligent Analysis Technology of Power Monitoring Video Data Based on Convolutional Neural Network
With the rapid increase of on-site monitoring objects and technological development, the power on-site image monitoring data has increased geometrically. For security managers, it is necessary to efficiently and quickly identify valid data and conduct intelligent early warning. Therefore, this paper proposes an intelligent analysis method of power field surveillance video data based on convolutional neural network. Firstly, the original surveillance video material is extracted. Secondly, the video cloud storage platform is used for storage and data cleaning. At the same time, the hidden danger behaviors are classified and analyzed and marked. Finally, the proposed method is used for feature extraction, model training and field verification to realize intelligent early warning analysis of video big data. The field application effect shows that the method proposed in this paper can realize the functions of video image data feature extraction, model training, and improve the effect of image processing. Eventually, it can meet the needs of on-site video data intelligent analysis and has a certain promotion prospect.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2461-2464
Research on Intelligent Analysis Technology of Power Monitoring Video Data Based on Convolutional Neural Network
With the rapid increase of on-site monitoring objects and technological development, the power on-site image monitoring data has increased geometrically. For security managers, it is necessary to efficiently and quickly identify valid data and conduct intelligent early warning. Therefore, this paper proposes an intelligent analysis method of power field surveillance video data based on convolutional neural network. Firstly, the original surveillance video material is extracted. Secondly, the video cloud storage platform is used for storage and data cleaning. At the same time, the hidden danger behaviors are classified and analyzed and marked. Finally, the proposed method is used for feature extraction, model training and field verification to realize intelligent early warning analysis of video big data. The field application effect shows that the method proposed in this paper can realize the functions of video image data feature extraction, model training, and improve the effect of image processing. Eventually, it can meet the needs of on-site video data intelligent analysis and has a certain promotion prospect.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87  (11) , 113308
An instrument for measuring scintillators efficiently based on silicon photomultipliers
An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87  (11) , 113308
An instrument for measuring scintillators efficiently based on silicon photomultipliers
An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.
- 1 January 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 107, 177-182
Far field 3D localization of radioactive hot spots using a coded aperture camera
- 1 January 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 107, 177-182
Far field 3D localization of radioactive hot spots using a coded aperture camera
- 1 October 2015
- Published by IOP Publishing in Chinese Physics C
- Vol. 39  (10) , 108202
Attenuation correction with region growing method used in the positron emission mammography imaging system
The Positron Emission Mammography imaging system (PEMi) provides a novel nuclear diagnosis method dedicated for breast imaging. With a better resolution than whole body PET, PEMi can detect millimeter-sized breast tumors. To address the requirement of semi-quantitative analysis with a radiotracer concentration map of the breast, a new attenuation correction method based on a three-dimensional seeded region growing image segmentation (3DSRG-AC) method has been developed. The method gives a 3D connected region as the segmentation result instead of image slices. The continuity property of the segmentation result makes this new method free of activity variation of breast tissues. The threshold value chosen is the key process for the segmentation method. The first valley in the grey level histogram of the reconstruction image is set as the lower threshold, which works well in clinical application. Results show that attenuation correction for PEMi improves the image quality and the quantitative accuracy of radioactivity distribution determination. Attenuation correction also improves the probability of detecting small and early breast tumors.
- 1 October 2015
- Published by IOP Publishing in Chinese Physics C
- Vol. 39  (10) , 108202
Attenuation correction with region growing method used in the positron emission mammography imaging system
The Positron Emission Mammography imaging system (PEMi) provides a novel nuclear diagnosis method dedicated for breast imaging. With a better resolution than whole body PET, PEMi can detect millimeter-sized breast tumors. To address the requirement of semi-quantitative analysis with a radiotracer concentration map of the breast, a new attenuation correction method based on a three-dimensional seeded region growing image segmentation (3DSRG-AC) method has been developed. The method gives a 3D connected region as the segmentation result instead of image slices. The continuity property of the segmentation result makes this new method free of activity variation of breast tissues. The threshold value chosen is the key process for the segmentation method. The first valley in the grey level histogram of the reconstruction image is set as the lower threshold, which works well in clinical application. Results show that attenuation correction for PEMi improves the image quality and the quantitative accuracy of radioactivity distribution determination. Attenuation correction also improves the probability of detecting small and early breast tumors.
- 24 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62  (5) , 2048-2056
Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)
A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 ~ 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 \thinspace766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.
- 24 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62  (5) , 2048-2056
Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)
A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 ~ 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 \thinspace766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.
- 1 June 2015
- Published by Elsevier in Radiation Measurements
- Vol. 77, 34-40
Development of a panorama coded-aperture gamma camera for radiation detection
- 1 June 2015
- Published by Elsevier in Radiation Measurements
- Vol. 77, 34-40
Development of a panorama coded-aperture gamma camera for radiation detection
- 1 March 2015
- Published by IOP Publishing in Chinese Physics C
- Vol. 39  (3) , 038201
A region segmentation based algorithm for building a crystal position lookup table in a scintillation detector
In a scintillation detector, scintillation crystals are typically made into a 2-dimensional modular array. The location of incident gamma-ray needs be calibrated due to spatial response nonlinearity. Generally, position histograms-the characteristic flood response of scintillation detectors-are used for position calibration. In this paper, a position calibration method based on a crystal position lookup table which maps the inaccurate location calculated by Anger logic to the exact hitting crystal position has been proposed. Firstly, the position histogram is preprocessed, such as noise reduction and image enhancement. Then the processed position histogram is segmented into disconnected regions, and crystal marking points are labeled by finding the centroids of regions. Finally, crystal boundaries are determined and the crystal position lookup table is generated. The scheme is evaluated by the whole-body positron emission tomography (PET) scanner and breast dedicated single photon emission computed tomography scanner developed by the Institute of High Energy Physics, Chinese Academy of Sciences. The results demonstrate that the algorithm is accurate, efficient, robust and applicable to any configurations of scintillation detector.
- 1 March 2015
- Published by IOP Publishing in Chinese Physics C
- Vol. 39  (3) , 038201
A region segmentation based algorithm for building a crystal position lookup table in a scintillation detector
In a scintillation detector, scintillation crystals are typically made into a 2-dimensional modular array. The location of incident gamma-ray needs be calibrated due to spatial response nonlinearity. Generally, position histograms-the characteristic flood response of scintillation detectors-are used for position calibration. In this paper, a position calibration method based on a crystal position lookup table which maps the inaccurate location calculated by Anger logic to the exact hitting crystal position has been proposed. Firstly, the position histogram is preprocessed, such as noise reduction and image enhancement. Then the processed position histogram is segmented into disconnected regions, and crystal marking points are labeled by finding the centroids of regions. Finally, crystal boundaries are determined and the crystal position lookup table is generated. The scheme is evaluated by the whole-body positron emission tomography (PET) scanner and breast dedicated single photon emission computed tomography scanner developed by the Institute of High Energy Physics, Chinese Academy of Sciences. The results demonstrate that the algorithm is accurate, efficient, robust and applicable to any configurations of scintillation detector.
- 1 January 2015
- Published by IOP Publishing in Chinese Physics B
- Vol. 24  (1)
PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response
- 1 January 2015
- Published by IOP Publishing in Chinese Physics B
- Vol. 24  (1)
PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response
- 1 February 2014
- Published by IOP Publishing in Chinese Physics B
- Vol. 23  (2) , 027802
A generalized method of converting CT image to PET linear attenuation coefficient distribution in PET/CT imaging
- 1 February 2014
- Published by IOP Publishing in Chinese Physics B
- Vol. 23  (2) , 027802
A generalized method of converting CT image to PET linear attenuation coefficient distribution in PET/CT imaging