Implementation of a Chloride‐selective Electrode Into a Closed Bipolar Electrode System with Fluorimetric Readout
- 7 January 2020
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 32 (4) , 812-819
Abstract
Applicability of a bipolar electrode system was tested for arrangements containing a typical ion‐selective electrode (ISE) connected with an electrode coated by a conducting polymer characterized by electroluminescence. In this case a selective response of the ISE membrane at one pole of the bipolar electrode is transduced to a fluorimetric signal obtained by reduction of the conducting polymer at the second pole. This signal transformation mode was studied on example of a simple closed bipolar electrode system composed of all‐solid‐state chloride‐selective electrode with polypyrrole transducer as the sensing pole and the reporting pole represented by electrode coated by poly(3‐octylthiophene) (POT) layer characterized by fluorescence in the neutral state. In this system selective and linear dependences of fluorimetric signal on logarithm of chloride ions concentration in turn‐on mode were recorded for optimized external voltage applied. Alternatively, a concept of cascade bipolar electrode system with incorporation of additional bipolar electrode being a polarization source for the sensing bipolar electrode with ISE and POT layer was also tested. A significant advantage of the cascade system is its possibility to work spontaneously without external polarization. For this case also linear calibration plots of fluorimetric signal vs. logarithm of analyte concentration were recorded.Keywords
Funding Information
- Narodowe Centrum Nauki (2016/21/B/ST4/03869)
This publication has 29 references indexed in Scilit:
- Fluorescence Coupling for Direct Imaging of Electrocatalytic HeterogeneityJournal of the American Chemical Society, 2012
- Coupled Electrochemical Reactions at Bipolar Microelectrodes and NanoelectrodesAnalytical Chemistry, 2012
- Bipolar Electrodes for Rapid Screening of ElectrocatalystsJournal of the American Chemical Society, 2011
- Shaping and exploring the micro- and nanoworld using bipolar electrochemistryAnalytical and Bioanalytical Chemistry, 2011
- Single Molecule Spectroscopy of Poly 3-octyl-thiophene (P3OT)Journal of Fluorescence, 2007
- Fluorescence quantum yield of poly(3‐octylthiophene) upon electrochemical dopingJournal of Applied Polymer Science, 2006
- Lowering the Detection Limit of Ion-Selective Plastic Membrane Electrodes with Conducting Polymer Solid Contact and Conducting Polymer Potentiometric SensorsAnalytical Chemistry, 2003
- Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron TransducersAnalytical Chemistry, 1999
- All-solid-state sodium-selective electrode based on a calixarene ionophore in a poly(vinyl chloride) membrane with a polypyrrole solid contactAnalytical Chemistry, 1992
- A Preliminary Investigation of Fluidized Bed ElectrodesJournal of the Electrochemical Society, 1969