Multicenter Experience with Transvenous Lead Extraction of Active Fixation Coronary Sinus Leads
Authors:
- 20 March 2012
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (6) , 641-647
Abstract
Active fixation coronary sinus (CS) leads limit dislodgement and represent an attractive option to the implanter. Although extraction of passive fixation CS leads is a common and frequently uncomplicated procedure, data regarding extraction of chronically implanted active fixation CS leads are limited. We performed a retrospective cohort study of patients undergoing active fixation CS lead extraction at six centers. Patient and procedural characteristics, indications for extraction, use of extraction sheath (ES) assistance, and outcomes are reported. Between January 2009 and February 2011, 12 patients underwent transvenous lead extraction (TLE) of Medtronic StarFix® lead (Medtronic Inc., Minneapolis, MN, USA). The cohort was 83% male with mean age 71 ± 14 years. Average implant duration was 14.2 ± 5.7 months (2.3-23.6). All leads but one were removed for infectious indications (67% systemic infection). At the time of explant, the fixation lobes were completely retracted in only one of the 12 cases and ES assistance was required for lead removal in all cases (58% laser, 25% cutting, 25% mechanical, and 25% femoral). The majority of cases required advancement of the sheath into the CS (75.0%) and often into a branch vessel (41.7%). One lead could not be removed transvenously and required surgical lead extraction. There were no major complications. Examination of the leads after extraction frequently revealed significant tissue growth into the fixation lobes. Although TLE of active fixation CS leads can be a safe procedure in select patients and experienced hands, powered sheaths and aggressive techniques are frequently required for successful removal despite relatively short implant durations. This raises significant concern regarding future TLE of active fixation CS leads with longer implant durations.Keywords
This publication has 15 references indexed in Scilit:
- Large, Single‐Center Experience in Transvenous Coronary Sinus Lead Extraction: Procedural Outcomes and Predictors for Mechanical DilatationPacing and Clinical Electrophysiology, 2011
- A Modified Transvenous Single Mechanical Dilatation Technique to Remove a Chronically Implanted Active‐Fixation Coronary Sinus Pacing LeadPacing and Clinical Electrophysiology, 2011
- Fibrotic Tissue Growth into the Extendable Lobes of an Active Fixation Coronary Sinus Lead Can Complicate ExtractionPacing and Clinical Electrophysiology, 2010
- Extraction of chronic pacemaker and defibrillator leads from the coronary sinus: laser infrequently used but requiredEP Europace, 2008
- LV Lead Fixation in a Coronary Vein May Be the Cause and Result of ThrombosisPacing and Clinical Electrophysiology, 2008
- First experience with a new active fixation coronary sinus leadEP Europace, 2007
- Usefulness of mechanical transvenous dilation and location of areas of adherence in patients undergoing coronary sinus lead extractionEP Europace, 2007
- Implications and Outcome of Permanent Coronary Sinus Lead Extraction and ReimplantationJournal of Cardiovascular Electrophysiology, 2005
- Coronary Sinus Lead Extraction in the Era of Cardiac Resynchronization Therapy:Pacing and Clinical Electrophysiology, 2005
- Coronary Sinus Lead ExtractionPacing and Clinical Electrophysiology, 2003