A computational thrombus formation model: application to an idealized two-dimensional aneurysm treated with bare metal coils
Authors:
- 3 August 2018
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 17 (6) , 1821-1838
Abstract
Cardiovascular implantable devices alter the biofluid dynamics and biochemistry of the blood in which they are placed. These perturbations can lead to thrombus formation which may or may not be desired, depending on the application. In this work, a computational model is developed that couples biofluid dynamics and biochemistry to predict the clotting response of blood to such devices. The model consists of 28 advection–diffusion–reaction partial differential equations to track proteins in the blood involved in clotting and utilizes boundary flux terms to model the initiation of the intrinsic clotting pathway at thrombogenic device surfaces. We use this model to simulate the transient clot growth within a 2D idealized bifurcation aneurysm filled with various distributions of bare metal coils with similar packing densities. The clot model predicts initial clot formation to occur in areas along coil surfaces where flow is minimal and where time-averaged shear rates are the smallest. Among the six coil-filled aneurysm cases simulated, maximum thrombus occlusion ranged between 80.8 and 92.2% of the post-treatment aneurysm volume and was achieved 325–450 s after treatment. With further refinement and validation, the computational clotting model will be a valuable engineering tool for evaluating and comparing the relative performance of cardiovascular implantable devices.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R01EB000462)
This publication has 72 references indexed in Scilit:
- In Vitro and Computational Thrombosis on Artificial Surfaces With Shear StressArtificial Organs, 2010
- Flow Residence Time and Regions of Intraluminal Thrombus Deposition in Intracranial AneurysmsAnnals of Biomedical Engineering, 2010
- A Multiscale Model of Venous Thrombus Formation with Surface-Mediated Control of Blood Coagulation CascadeBiophysical Journal, 2010
- Surface-energy dependent contact activation of blood factor XIIBiomaterials, 2010
- A model for the formation, growth, and lysis of clots in quiescent plasma. A comparison between the effects of antithrombin III deficiency and protein C deficiencyJournal of Theoretical Biology, 2008
- A multiscale model of thrombus developmentJournal of The Royal Society Interface, 2007
- Computationally Derived Points of Fragility of a Human Cascade Are Consistent with Current Therapeutic StrategiesPLOS Computational Biology, 2007
- A PRESSURE-BASED METHOD FOR UNSTRUCTURED MESHESNumerical Heat Transfer, Part B: Fundamentals, 1997
- Kinetics of coagulation factor-X activation by platelet-bound factor IXaBiochemistry, 1990
- MECHANISMS FOR HAGEMAN FACTOR ACTIVATION AND ROLE OF HMW KININOGEN AS A COAGULATION COFACTORAnnals of the New York Academy of Sciences, 1981