Jason M. Ortega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jason M. Ortega has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Duncan J. Maitland
Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States
3 shared publicationsJ. Hartman
Department of Neurosurgery, Kaiser Permanente Medical Center, Sacramento, USA
2 shared publicationsJohn D. Horn
Department of Biomedical Engineering, Texas A&M University, College Station, TX, United States; Computational Engineering Division, Lawrence Livermore National Laboratory, P.O. Box 808, L-090, Livermore, CA 94551, United States
2 shared publicationsJonathan Hartman
Department of Neurological Surgery, Kaiser Permanente Sacramento Medical Center, Sacramento, CA, United States
2 shared publications- Thomas S. Wilson
Lawrence Livermore National Laboratory, Livermore, CA, 94550, USA
2 shared publications Adam W. Jaycox
Lawrence Livermore National Laboratory 7000 East Avenue, L‐090 Livermore CA 94551 USA
1 shared publication
Latest Publications
- Open Access
- 28 June 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (27)
Aerodynamic integration produces a vehicle shape with a negative drag coefficient
Negative drag coefficients are normally associated with a vessel outfitted with a sail to extract energy from the wind and propel the vehicle forward. Therefore, the notion of a heavy vehicle, that is, a semi truck, that generates negative aerodynamic drag without a sail or any external appendages may seem implausible, especially given the fact that these vehicles have some of the largest drag coefficients on the road today. However, using both wind tunnel measurements and computational fluid dynamics simulations, we demonstrate aerodynamically integrated vehicle shapes that generate negative body-axis drag in a crosswind as a result of large negative frontal pressures that effectively “pull” the vehicle forward against the wind, much like a sailboat. While negative body-axis drag exists only for wind yaw angles above a certain analytical threshold, the negative frontal pressures exist at smaller yaw angles and subsequently produce body-axis drag coefficients that are significantly less than those of modern heavy vehicles. The application of this aerodynamic phenomenon to the heavy vehicle industry would produce sizable reductions in petroleum use throughout the United States.
- 28 June 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (27)
Open AccessAerodynamic integration produces a vehicle shape with a negative drag coefficient
Negative drag coefficients are normally associated with a vessel outfitted with a sail to extract energy from the wind and propel the vehicle forward. Therefore, the notion of a heavy vehicle, that is, a semi truck, that generates negative aerodynamic drag without a sail or any external appendages may seem implausible, especially given the fact that these vehicles have some of the largest drag coefficients on the road today. However, using both wind tunnel measurements and computational fluid dynamics simulations, we demonstrate aerodynamically integrated vehicle shapes that generate negative body-axis drag in a crosswind as a result of large negative frontal pressures that effectively “pull” the vehicle forward against the wind, much like a sailboat. While negative body-axis drag exists only for wind yaw angles above a certain analytical threshold, the negative frontal pressures exist at smaller yaw angles and subsequently produce body-axis drag coefficients that are significantly less than those of modern heavy vehicles. The application of this aerodynamic phenomenon to the heavy vehicle industry would produce sizable reductions in petroleum use throughout the United States.
- Top Cited PapersOpen Access
- 20 November 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (47) , eabc7429
3D printed gradient index glass optics
Multimaterial 3D printing enables a novel approach to fabrication of glass optics with tailored refractive index gradients.
- 20 November 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (47) , eabc7429
Top Cited PapersOpen Access3D printed gradient index glass optics
Multimaterial 3D printing enables a novel approach to fabrication of glass optics with tailored refractive index gradients.
- 28 October 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 75 (1) , 65-71
Computational study of clot formation in aneurysms treated with shape memory polymer foam
To prevent aneurysmal rupture, intracranial aneurysms are often treated with endovascular metal coils that fill the aneurysm sac and stimulate thrombus formation, thereby isolating the aneurysm from the arterial flow. Despite its widespread use, this method can result in suboptimal outcomes leading to aneurysm recurrence. Recently, shape memory polymer foam has been proposed as an alternative aneurysm filler. In this work, a computational thrombus model is used to predict the clotting response within idealized 2D aneurysms virtually treated with foam. The results are compared to previously reported clot formation predictions in identical 2D aneurysm geometries filled with simplified endovascular metal coil shapes. Each of the foam-filled aneurysms reached at least 94% thrombus occlusion regardless of foam pore size or orientation, whereas the final thrombus occlusion within the coil-filled aneurysms varied from 80.8 to 92.2% with many of the cases leaving large areas in the aneurysm neck unfilled. Based on the simulations presented here, shape memory polymer foams may be able to produce more predictable, uniform, and complete clotting results than bare metal coils, independent of foam geometry or orientation.
- 28 October 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 75 (1) , 65-71
Computational study of clot formation in aneurysms treated with shape memory polymer foam
To prevent aneurysmal rupture, intracranial aneurysms are often treated with endovascular metal coils that fill the aneurysm sac and stimulate thrombus formation, thereby isolating the aneurysm from the arterial flow. Despite its widespread use, this method can result in suboptimal outcomes leading to aneurysm recurrence. Recently, shape memory polymer foam has been proposed as an alternative aneurysm filler. In this work, a computational thrombus model is used to predict the clotting response within idealized 2D aneurysms virtually treated with foam. The results are compared to previously reported clot formation predictions in identical 2D aneurysm geometries filled with simplified endovascular metal coil shapes. Each of the foam-filled aneurysms reached at least 94% thrombus occlusion regardless of foam pore size or orientation, whereas the final thrombus occlusion within the coil-filled aneurysms varied from 80.8 to 92.2% with many of the cases leaving large areas in the aneurysm neck unfilled. Based on the simulations presented here, shape memory polymer foams may be able to produce more predictable, uniform, and complete clotting results than bare metal coils, independent of foam geometry or orientation.
- 12 April 2019
- Published by Wiley in Advanced Materials Technologies
- Vol. 4 (7)
Active Mixing of Disparate Inks for Multimaterial 3D Printing
3D printing of multimaterial parts relies upon efficient mixing of the ink components and a rapid response to composition changes. However, at low Reynolds numbers and large Peclet numbers, mixing disparate viscosity and density inks poses a challenge. In this study, the performance of active micromixers for disparate non‐Newtonian inks is evaluated using both experiments and computational fluid dynamics simulations. The mixing efficiencies are compared with scaling relationships for active micromixers. Using detailed simulation results, multiple factors are identified that can impact the micromixer response time during a composition change. Lastly, an active micromixer is proposed and evaluated to efficiently mix arbitrary multimaterial ink compositions and produce fine composition gradients within printed parts.
- 12 April 2019
- Published by Wiley in Advanced Materials Technologies
- Vol. 4 (7)
Active Mixing of Disparate Inks for Multimaterial 3D Printing
3D printing of multimaterial parts relies upon efficient mixing of the ink components and a rapid response to composition changes. However, at low Reynolds numbers and large Peclet numbers, mixing disparate viscosity and density inks poses a challenge. In this study, the performance of active micromixers for disparate non‐Newtonian inks is evaluated using both experiments and computational fluid dynamics simulations. The mixing efficiencies are compared with scaling relationships for active micromixers. Using detailed simulation results, multiple factors are identified that can impact the micromixer response time during a composition change. Lastly, an active micromixer is proposed and evaluated to efficiently mix arbitrary multimaterial ink compositions and produce fine composition gradients within printed parts.
- 3 August 2018
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 17 (6) , 1821-1838
A computational thrombus formation model: application to an idealized two-dimensional aneurysm treated with bare metal coils
Cardiovascular implantable devices alter the biofluid dynamics and biochemistry of the blood in which they are placed. These perturbations can lead to thrombus formation which may or may not be desired, depending on the application. In this work, a computational model is developed that couples biofluid dynamics and biochemistry to predict the clotting response of blood to such devices. The model consists of 28 advection–diffusion–reaction partial differential equations to track proteins in the blood involved in clotting and utilizes boundary flux terms to model the initiation of the intrinsic clotting pathway at thrombogenic device surfaces. We use this model to simulate the transient clot growth within a 2D idealized bifurcation aneurysm filled with various distributions of bare metal coils with similar packing densities. The clot model predicts initial clot formation to occur in areas along coil surfaces where flow is minimal and where time-averaged shear rates are the smallest. Among the six coil-filled aneurysm cases simulated, maximum thrombus occlusion ranged between 80.8 and 92.2% of the post-treatment aneurysm volume and was achieved 325–450 s after treatment. With further refinement and validation, the computational clotting model will be a valuable engineering tool for evaluating and comparing the relative performance of cardiovascular implantable devices.
- 3 August 2018
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 17 (6) , 1821-1838
A computational thrombus formation model: application to an idealized two-dimensional aneurysm treated with bare metal coils
Cardiovascular implantable devices alter the biofluid dynamics and biochemistry of the blood in which they are placed. These perturbations can lead to thrombus formation which may or may not be desired, depending on the application. In this work, a computational model is developed that couples biofluid dynamics and biochemistry to predict the clotting response of blood to such devices. The model consists of 28 advection–diffusion–reaction partial differential equations to track proteins in the blood involved in clotting and utilizes boundary flux terms to model the initiation of the intrinsic clotting pathway at thrombogenic device surfaces. We use this model to simulate the transient clot growth within a 2D idealized bifurcation aneurysm filled with various distributions of bare metal coils with similar packing densities. The clot model predicts initial clot formation to occur in areas along coil surfaces where flow is minimal and where time-averaged shear rates are the smallest. Among the six coil-filled aneurysm cases simulated, maximum thrombus occlusion ranged between 80.8 and 92.2% of the post-treatment aneurysm volume and was achieved 325–450 s after treatment. With further refinement and validation, the computational clotting model will be a valuable engineering tool for evaluating and comparing the relative performance of cardiovascular implantable devices.
- Open Access
- 12 October 2013
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 103
Porous media properties of reticulated shape memory polymer foams and mock embolic coils for aneurysm treatment
Shape memory polymer (SMP) foams are being investigated as an alternative aneurysm treatment method to embolic coils. The goal of both techniques is the reduction of blood flow into the aneurysm and the subsequent formation of a stable thrombus, which prevents future aneurysm rupture. The purpose of this study is to experimentally determine the parameters, permeability and form factor, which are related to the flow resistance imposed by both media when subjected to a pressure gradient. The porous media properties—permeability and form factor—of SMP foams and mock embolic coils (MECs) were measured with a pressure gradient method by means of an in vitro closed flow loop. We implemented the Forchheimer-Hazen-Dupuit-Darcy equation to calculate these properties. Mechanically-reticulated SMP foams were fabricated with average cell sizes of 0.7E-3 and 1.1E-3 m, while the MECs were arranged with volumetric packing densities of 11-28%. The permeability of the SMP foams was an order of magnitude lower than that of the MECs. The form factor differed by up to two orders of magnitude and was higher for the SMP foams in all cases. The maximum flow rate of all samples tested was within the inertial laminar flow regime, with Reynolds numbers ranging between 1 and 35. The SMP foams impose a greater resistance to fluid flow compared to MECs, which is a result of increased viscous and inertial losses. These results suggest that aneurysms treated with SMP foam will have flow conditions more favorable for blood stasis than those treated with embolic coils having packing densities ≤ 28%.
- 12 October 2013
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 103
Open AccessPorous media properties of reticulated shape memory polymer foams and mock embolic coils for aneurysm treatment
Shape memory polymer (SMP) foams are being investigated as an alternative aneurysm treatment method to embolic coils. The goal of both techniques is the reduction of blood flow into the aneurysm and the subsequent formation of a stable thrombus, which prevents future aneurysm rupture. The purpose of this study is to experimentally determine the parameters, permeability and form factor, which are related to the flow resistance imposed by both media when subjected to a pressure gradient. The porous media properties—permeability and form factor—of SMP foams and mock embolic coils (MECs) were measured with a pressure gradient method by means of an in vitro closed flow loop. We implemented the Forchheimer-Hazen-Dupuit-Darcy equation to calculate these properties. Mechanically-reticulated SMP foams were fabricated with average cell sizes of 0.7E-3 and 1.1E-3 m, while the MECs were arranged with volumetric packing densities of 11-28%. The permeability of the SMP foams was an order of magnitude lower than that of the MECs. The form factor differed by up to two orders of magnitude and was higher for the SMP foams in all cases. The maximum flow rate of all samples tested was within the inertial laminar flow regime, with Reynolds numbers ranging between 1 and 35. The SMP foams impose a greater resistance to fluid flow compared to MECs, which is a result of increased viscous and inertial losses. These results suggest that aneurysms treated with SMP foam will have flow conditions more favorable for blood stasis than those treated with embolic coils having packing densities ≤ 28%.
- 1 August 2013
- Published by Elsevier in Chemical Engineering Science
- Vol. 99, 59-66
A porous media model for blood flow within reticulated foam
- 1 August 2013
- Published by Elsevier in Chemical Engineering Science
- Vol. 99, 59-66
A porous media model for blood flow within reticulated foam
- 18 January 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (4) , 725-743
Virtual Treatment of Basilar Aneurysms Using Shape Memory Polymer Foam
Numerical simulations are performed on patient-specific basilar aneurysms that are treated with shape memory polymer (SMP) foam. In order to assess the post-treatment hemodynamics, two modeling approaches are employed. In the first, the foam geometry is obtained from a micro-CT scan and the pulsatile blood flow within the foam is simulated for both Newtonian and non-Newtonian viscosity models. In the second, the foam is represented as a porous media continuum, which has permeability properties that are determined by computing the pressure gradient through the foam geometry over a range of flow speeds comparable to those of in vivo conditions. Virtual angiography and additional post-processing demonstrate that the SMP foam significantly reduces the blood flow speed within the treated aneurysms, while eliminating the high-frequency velocity fluctuations that are present within the pre-treatment aneurysms. An estimation of the initial locations of thrombus formation throughout the SMP foam is obtained by means of a low fidelity thrombosis model that is based upon the residence time and shear rate of blood. The Newtonian viscosity model and the porous media model capture similar qualitative trends, though both yield a smaller volume of thrombus within the SMP foam.
- 18 January 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (4) , 725-743
Virtual Treatment of Basilar Aneurysms Using Shape Memory Polymer Foam
Numerical simulations are performed on patient-specific basilar aneurysms that are treated with shape memory polymer (SMP) foam. In order to assess the post-treatment hemodynamics, two modeling approaches are employed. In the first, the foam geometry is obtained from a micro-CT scan and the pulsatile blood flow within the foam is simulated for both Newtonian and non-Newtonian viscosity models. In the second, the foam is represented as a porous media continuum, which has permeability properties that are determined by computing the pressure gradient through the foam geometry over a range of flow speeds comparable to those of in vivo conditions. Virtual angiography and additional post-processing demonstrate that the SMP foam significantly reduces the blood flow speed within the treated aneurysms, while eliminating the high-frequency velocity fluctuations that are present within the pre-treatment aneurysms. An estimation of the initial locations of thrombus formation throughout the SMP foam is obtained by means of a low fidelity thrombosis model that is based upon the residence time and shear rate of blood. The Newtonian viscosity model and the porous media model capture similar qualitative trends, though both yield a smaller volume of thrombus within the SMP foam.
- 16 July 2008
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 36 (9) , 1531-1546
Post-Treatment Hemodynamics of a Basilar Aneurysm and Bifurcation
To investigate whether or not a successful aneurysm treatment procedure can subject a parent artery to harmful hemodynamic stresses, computational fluid dynamics simulations are performed on a patient-specific basilar aneurysm and bifurcation before and after a virtual endovascular treatment. Prior to treatment, the aneurysm at systole is filled with a periodic train of vortex tubes, which form at the aneurysm neck and advect upwards into the dome. Following the treatment procedure however, the motion of the vortex train is inhibited by the aneurysm filling material, which confines the vortex tubes to the region beneath the aneurysm neck. Analysis of the post-treatment flow field indicates that the impingement of the basilar artery flow upon the treated aneurysm neck and the close proximity of a vortex tube to the parent artery wall increase the maximum wall shear stresses to values approximately equal to 50 Pa at systole. Calculation of the time-averaged wall shear stresses indicates that there is a 1.4 × 10−7 m2 area on the parent artery exposed to wall shear stresses greater than 37.9 Pa, a value shown by Fry [Circ. Res. 22(2):165–197, 1968] to cause severe damage to the endothelial cells that line the artery wall. The results of this study demonstrate that it is possible for a treatment procedure, which successfully isolates the aneurysm from the circulation and leaves no aneurysm neck remnant, to elevate the hemodynamic stresses to levels that are injurious to the artery wall.
- 16 July 2008
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 36 (9) , 1531-1546
Post-Treatment Hemodynamics of a Basilar Aneurysm and Bifurcation
To investigate whether or not a successful aneurysm treatment procedure can subject a parent artery to harmful hemodynamic stresses, computational fluid dynamics simulations are performed on a patient-specific basilar aneurysm and bifurcation before and after a virtual endovascular treatment. Prior to treatment, the aneurysm at systole is filled with a periodic train of vortex tubes, which form at the aneurysm neck and advect upwards into the dome. Following the treatment procedure however, the motion of the vortex train is inhibited by the aneurysm filling material, which confines the vortex tubes to the region beneath the aneurysm neck. Analysis of the post-treatment flow field indicates that the impingement of the basilar artery flow upon the treated aneurysm neck and the close proximity of a vortex tube to the parent artery wall increase the maximum wall shear stresses to values approximately equal to 50 Pa at systole. Calculation of the time-averaged wall shear stresses indicates that there is a 1.4 × 10−7 m2 area on the parent artery exposed to wall shear stresses greater than 37.9 Pa, a value shown by Fry [Circ. Res. 22(2):165–197, 1968] to cause severe damage to the endothelial cells that line the artery wall. The results of this study demonstrate that it is possible for a treatment procedure, which successfully isolates the aneurysm from the circulation and leaves no aneurysm neck remnant, to elevate the hemodynamic stresses to levels that are injurious to the artery wall.
- 20 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (9) , 1722-1724
A Shape Memory Polymer Dialysis Needle Adapter for the Reduction of Hemodynamic Stress Within Arteriovenous Grafts
A deployable, shape memory polymer adapter is investigated for reducing the hemodynamic stress caused by dialysis needle flow impingement within an arteriovenous graft. Computational fluid dynamics simulations of dialysis sessions with and without the adapter demonstrate that the adapter provides a significant decrease in the wall shear stress. Preliminary in vitro flow visualization measurements are made within a graft model following delivery and actuation of a prototype shape memory polymer adapter. Both the simulations and the qualitative flow visualization measurements demonstrate that the adapter reduces the severity of the dialysis needle flow impingement on the vascular access graft.
- 20 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (9) , 1722-1724
A Shape Memory Polymer Dialysis Needle Adapter for the Reduction of Hemodynamic Stress Within Arteriovenous Grafts
A deployable, shape memory polymer adapter is investigated for reducing the hemodynamic stress caused by dialysis needle flow impingement within an arteriovenous graft. Computational fluid dynamics simulations of dialysis sessions with and without the adapter demonstrate that the adapter provides a significant decrease in the wall shear stress. Preliminary in vitro flow visualization measurements are made within a graft model following delivery and actuation of a prototype shape memory polymer adapter. Both the simulations and the qualitative flow visualization measurements demonstrate that the adapter reduces the severity of the dialysis needle flow impingement on the vascular access graft.