Smartphone Movement Sensors for Remote Monitoring of Respiratory Rate: Observational Study (Preprint)
Preprint
- 23 June 2021
- preprint
- Published by JMIR Publications Inc. in JMIR Preprints
Abstract
BACKGROUND Mobile health (mHealth) offers notable potential clinical and economic benefits to patients and healthcare systems alike. Although respiratory rate (RR) is of great clinical significance, existing remote technologies to measure RR suffer from limitations, such as cost, accessibility and reliability. Using smartphone movement sensors to measure RR may offer a potential solution to these shortcomings. OBJECTIVE The aim of this study was to conduct a comprehensive and ecologically valid assessment of a novel mHealth smartphone application designed to measure RR using movement sensors. METHODS Study 1 offered a preliminary evaluation, in which RR measurements from 15 participants generated via the mHealth app were compared to simultaneous measurements from a reference device cleared by the US Food and Drug Administration (FDA). Participants’ ability to successfully operate the app was also determined. Finally, a novel reference method, that would allow accuracy of the mHealth app to be investigated ‘in the wild’, was assessed for validity against the FDA-cleared reference. In Study 2, 165 participants of balanced demographics remotely downloaded the mHealth app and measured their RR. Measures from the mHealth app were compared to the novel reference that was assessed in Study 1. Usability was quantified based on the proportion of participants that were able to successfully use the app to measure their RR and standardised usability scales. RESULTS Outcomes from Study 1 supported further assessment of the mHealth app, including as assessed by the novel reference. The mHealth app, when compared to the FDA-cleared and novel references, respectively, showed a mean absolute error (MAE) of 1.65 (standard deviation (SD) = 1.49) and 1.14 (1.44), relative MAE of 12.2 (9.23) and 9.5 (18.70) and bias of 0.81 (limits of agreement (LoA) = -3.27-4.89) and 0.08 (-3.68-3.51). Pearson Product Moment Correlation (PPMC) coefficients were 0.700 and 0.885. 93% of participants could successfully operate the device on their first use and standardised usability scores were above industry averages. CONCLUSIONS The accuracy and usability of the mHealth app demonstrated in this research hold promise for the use of mHealth solutions employing smartphone movement sensors to remotely monitor RR. Considering methodological limitations, further research should be undertaken to more holistically validate the benefits that this technology may offer patients and healthcare systems.Keywords
This publication has 37 references indexed in Scilit:
- Using Mobile Phone Sensors to Detect Rapid Respiratory Rate in the Diagnosis of PneumoniaInternational Journal of Engineering and Technology, 2016
- Clinical evaluation of a novel respiratory rate monitorJournal of Clinical Monitoring and Computing, 2015
- Assessing the impact of mHealth interventions in low- and middle-income countries – what has been shown to work?Global Health Action, 2014
- Respiratory Rate Estimation from the Built-in Cameras of Smartphones and TabletsAnnals of Biomedical Engineering, 2013
- The Accuracy, Precision and Reliability of Measuring Ventilatory Rate and Detecting Ventilatory Pause by Rainbow Acoustic Monitoring and CapnometryAnesthesia & Analgesia, 2013
- The Effectiveness of Mobile-Health Technology-Based Health Behaviour Change or Disease Management Interventions for Health Care Consumers: A Systematic ReviewPLOS Medicine, 2013
- Confusion, Urea, Respiratory Rate and Shock Index or Adjusted Shock Index (CURSI or CURASI) criteria predict mortality in community-acquired pneumoniaEuropean Journal of Internal Medicine, 2010
- CAN WE IMPROVE THE CLINICAL UTILITY OF RESPIRATORY RATE AS A MONITORED VITAL SIGN?Shock, 2009
- The Royal Marsden Hospital Manual of Clinical Nursing Procedures2007
- Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatientsJournal of General Internal Medicine, 1993