Mohammad A. Dabbah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad A. Dabbah has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Rayaz Ahmed Malik
Department of Medicine, Weill Cornell Medicine-Qatar, Doha, Qatar
8 shared publications - Wai Lok Woo
School of Computer Science, Northumbria University, Newcastle upon Tyne NE1 8ST, UK
8 shared publications - Mitra Tavakoli
Exeter Diabetes Centre of Excellence (EXCEED), Diabetes and Vascular Research Centre, National Institute for Health Research (NIHR), Exeter Clinical Research Facility University of Exeter Medical School Exeter UK
6 shared publications - Georgios Ponirakis
Research Division, Weill Cornell Medicine-Qatar, 24144 Doha, Qatar
4 shared publications Hassan Fadavi
Centre for Endocrinology and Diabetes, Institute of Human Development, Manchester Academic Health Science Centre, Manchester, U.K. Division of Medicine, Weill Cornell Medical College in Qatar, Doha, Qatar
4 shared publications- Uazman Alam
Department of Cardiovascular and Metabolic Medicine, University of Liverpool, Liverpool, UK
4 shared publications
Latest Publications
- Open Access
- 23 June 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Smartphone Movement Sensors for Remote Monitoring of Respiratory Rate: Observational Study (Preprint)
BACKGROUND Mobile health (mHealth) offers notable potential clinical and economic benefits to patients and healthcare systems alike. Although respiratory rate (RR) is of great clinical significance, existing remote technologies to measure RR suffer from limitations, such as cost, accessibility and reliability. Using smartphone movement sensors to measure RR may offer a potential solution to these shortcomings. OBJECTIVE The aim of this study was to conduct a comprehensive and ecologically valid assessment of a novel mHealth smartphone application designed to measure RR using movement sensors. METHODS Study 1 offered a preliminary evaluation, in which RR measurements from 15 participants generated via the mHealth app were compared to simultaneous measurements from a reference device cleared by the US Food and Drug Administration (FDA). Participants’ ability to successfully operate the app was also determined. Finally, a novel reference method, that would allow accuracy of the mHealth app to be investigated ‘in the wild’, was assessed for validity against the FDA-cleared reference. In Study 2, 165 participants of balanced demographics remotely downloaded the mHealth app and measured their RR. Measures from the mHealth app were compared to the novel reference that was assessed in Study 1. Usability was quantified based on the proportion of participants that were able to successfully use the app to measure their RR and standardised usability scales. RESULTS Outcomes from Study 1 supported further assessment of the mHealth app, including as assessed by the novel reference. The mHealth app, when compared to the FDA-cleared and novel references, respectively, showed a mean absolute error (MAE) of 1.65 (standard deviation (SD) = 1.49) and 1.14 (1.44), relative MAE of 12.2 (9.23) and 9.5 (18.70) and bias of 0.81 (limits of agreement (LoA) = -3.27-4.89) and 0.08 (-3.68-3.51). Pearson Product Moment Correlation (PPMC) coefficients were 0.700 and 0.885. 93% of participants could successfully operate the device on their first use and standardised usability scores were above industry averages. CONCLUSIONS The accuracy and usability of the mHealth app demonstrated in this research hold promise for the use of mHealth solutions employing smartphone movement sensors to remotely monitor RR. Considering methodological limitations, further research should be undertaken to more holistically validate the benefits that this technology may offer patients and healthcare systems.
- 23 June 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSmartphone Movement Sensors for Remote Monitoring of Respiratory Rate: Observational Study (Preprint)
BACKGROUND Mobile health (mHealth) offers notable potential clinical and economic benefits to patients and healthcare systems alike. Although respiratory rate (RR) is of great clinical significance, existing remote technologies to measure RR suffer from limitations, such as cost, accessibility and reliability. Using smartphone movement sensors to measure RR may offer a potential solution to these shortcomings. OBJECTIVE The aim of this study was to conduct a comprehensive and ecologically valid assessment of a novel mHealth smartphone application designed to measure RR using movement sensors. METHODS Study 1 offered a preliminary evaluation, in which RR measurements from 15 participants generated via the mHealth app were compared to simultaneous measurements from a reference device cleared by the US Food and Drug Administration (FDA). Participants’ ability to successfully operate the app was also determined. Finally, a novel reference method, that would allow accuracy of the mHealth app to be investigated ‘in the wild’, was assessed for validity against the FDA-cleared reference. In Study 2, 165 participants of balanced demographics remotely downloaded the mHealth app and measured their RR. Measures from the mHealth app were compared to the novel reference that was assessed in Study 1. Usability was quantified based on the proportion of participants that were able to successfully use the app to measure their RR and standardised usability scales. RESULTS Outcomes from Study 1 supported further assessment of the mHealth app, including as assessed by the novel reference. The mHealth app, when compared to the FDA-cleared and novel references, respectively, showed a mean absolute error (MAE) of 1.65 (standard deviation (SD) = 1.49) and 1.14 (1.44), relative MAE of 12.2 (9.23) and 9.5 (18.70) and bias of 0.81 (limits of agreement (LoA) = -3.27-4.89) and 0.08 (-3.68-3.51). Pearson Product Moment Correlation (PPMC) coefficients were 0.700 and 0.885. 93% of participants could successfully operate the device on their first use and standardised usability scores were above industry averages. CONCLUSIONS The accuracy and usability of the mHealth app demonstrated in this research hold promise for the use of mHealth solutions employing smartphone movement sensors to remotely monitor RR. Considering methodological limitations, further research should be undertaken to more holistically validate the benefits that this technology may offer patients and healthcare systems.
- Open Access
Machine learning approach to dynamic risk modeling of mortality in COVID-19: a UK Biobank study
The COVID-19 pandemic has created an urgent need for robust, scalable monitoring tools supporting stratification of high-risk patients. This research aims to develop and validate prediction models, using the UK Biobank, to estimate COVID-19 mortality risk in confirmed cases. From the 11,245 participants testing positive for COVID-19, we develop a data-driven random forest classification model with excellent performance (AUC: 0.91), using baseline characteristics, pre-existing conditions, symptoms, and vital signs, such that the score could dynamically assess mortality risk with disease deterioration. We also identify several significant novel predictors of COVID-19 mortality with equivalent or greater predictive value than established high-risk comorbidities, such as detailed anthropometrics and prior acute kidney failure, urinary tract infection, and pneumonias. The model design and feature selection enables utility in outpatient settings. Possible applications include supporting individual-level risk profiling and monitoring disease progression across patients with COVID-19 at-scale, especially in hospital-at-home settings.
Open AccessMachine learning approach to dynamic risk modeling of mortality in COVID-19: a UK Biobank study
The COVID-19 pandemic has created an urgent need for robust, scalable monitoring tools supporting stratification of high-risk patients. This research aims to develop and validate prediction models, using the UK Biobank, to estimate COVID-19 mortality risk in confirmed cases. From the 11,245 participants testing positive for COVID-19, we develop a data-driven random forest classification model with excellent performance (AUC: 0.91), using baseline characteristics, pre-existing conditions, symptoms, and vital signs, such that the score could dynamically assess mortality risk with disease deterioration. We also identify several significant novel predictors of COVID-19 mortality with equivalent or greater predictive value than established high-risk comorbidities, such as detailed anthropometrics and prior acute kidney failure, urinary tract infection, and pneumonias. The model design and feature selection enables utility in outpatient settings. Possible applications include supporting individual-level risk profiling and monitoring disease progression across patients with COVID-19 at-scale, especially in hospital-at-home settings.
- 1 October 2016
- Published by Springer Nature
- p. 139-146
Cross-Modality Anatomical Landmark Detection Using Histograms of Unsigned Gradient Orientations and Atlas Location Autocontext
- 1 October 2016
- Published by Springer Nature
- p. 139-146
Cross-Modality Anatomical Landmark Detection Using Histograms of Unsigned Gradient Orientations and Atlas Location Autocontext
- Top Cited PapersOpen Access
- 20 March 2015
- Published by American Diabetes Association in Diabetes Care
- Vol. 38 (6) , 1138-1144
Small Nerve Fiber Quantification in the Diagnosis of Diabetic Sensorimotor Polyneuropathy: Comparing Corneal Confocal Microscopy With Intraepidermal Nerve Fiber Density
OBJECTIVE: Quantitative assessment of small fiber damage is key to the early diagnosis and assessment of progression or regression of diabetic sensorimotor polyneuropathy (DSPN). Intraepidermal nerve fiber density (IENFD) is the current gold standard, but corneal confocal microscopy (CCM), an in vivo ophthalmic imaging modality, has the potential to be a noninvasive and objective image biomarker for identifying small fiber damage. The purpose of this study was to determine the diagnostic performance of CCM and IENFD by using the current guidelines as the reference standard. RESEARCH DESIGN AND METHODS: Eighty-nine subjects (26 control subjects and 63 patients with type 1 diabetes), with and without DSPN, underwent a detailed assessment of neuropathy, including CCM and skin biopsy. RESULTS: Manual and automated corneal nerve fiber density (CNFD) (P < 0.0001), branch density (CNBD) (P < 0.0001) and length (CNFL) (P < 0.0001), and IENFD (P < 0.001) were significantly reduced in patients with diabetes with DSPN compared with control subjects. The area under the receiver operating characteristic curve for identifying DSPN was 0.82 for manual CNFD, 0.80 for automated CNFD, and 0.66 for IENFD, which did not differ significantly (P = 0.14). CONCLUSIONS: This study shows comparable diagnostic efficiency between CCM and IENFD, providing further support for the clinical utility of CCM as a surrogate end point for DSPN.
- 20 March 2015
- Published by American Diabetes Association in Diabetes Care
- Vol. 38 (6) , 1138-1144
Top Cited PapersOpen AccessSmall Nerve Fiber Quantification in the Diagnosis of Diabetic Sensorimotor Polyneuropathy: Comparing Corneal Confocal Microscopy With Intraepidermal Nerve Fiber Density
OBJECTIVE: Quantitative assessment of small fiber damage is key to the early diagnosis and assessment of progression or regression of diabetic sensorimotor polyneuropathy (DSPN). Intraepidermal nerve fiber density (IENFD) is the current gold standard, but corneal confocal microscopy (CCM), an in vivo ophthalmic imaging modality, has the potential to be a noninvasive and objective image biomarker for identifying small fiber damage. The purpose of this study was to determine the diagnostic performance of CCM and IENFD by using the current guidelines as the reference standard. RESEARCH DESIGN AND METHODS: Eighty-nine subjects (26 control subjects and 63 patients with type 1 diabetes), with and without DSPN, underwent a detailed assessment of neuropathy, including CCM and skin biopsy. RESULTS: Manual and automated corneal nerve fiber density (CNFD) (P < 0.0001), branch density (CNBD) (P < 0.0001) and length (CNFL) (P < 0.0001), and IENFD (P < 0.001) were significantly reduced in patients with diabetes with DSPN compared with control subjects. The area under the receiver operating characteristic curve for identifying DSPN was 0.82 for manual CNFD, 0.80 for automated CNFD, and 0.66 for IENFD, which did not differ significantly (P = 0.14). CONCLUSIONS: This study shows comparable diagnostic efficiency between CCM and IENFD, providing further support for the clinical utility of CCM as a surrogate end point for DSPN.
- Open Access
- 1 January 2015
- Published by Wiley in Journal of Diabetes Research
- Vol. 2015, 1-7
Automated Quantification of Neuropad Improves Its Diagnostic Ability in Patients with Diabetic Neuropathy
Neuropad is currently a categorical visual screening test that identifies diabetic patients at risk of foot ulceration. The diagnostic performance of Neuropad was compared between the categorical and continuous (image-analysis (Sudometrics)) outputs to diagnose diabetic peripheral neuropathy (DPN). 110 subjects with type 1 and 2 diabetes underwent assessment with Neuropad, Neuropathy Disability Score (NDS), peroneal motor nerve conduction velocity (PMNCV), sural nerve action potential (SNAP), Deep Breathing-Heart Rate Variability (DB-HRV), intraepidermal nerve fibre density (IENFD), and corneal confocal microscopy (CCM). 46/110 patients had DPN according to the Toronto consensus. The continuous output displayed high sensitivity and specificity for DB-HRV (91%, 83%), CNFD (88%, 78%), and SNAP (88%, 83%), whereas the categorical output showed high sensitivity but low specificity. The optimal cut-off points were 90% for the detection of autonomic dysfunction (DB-HRV) and 80% for small fibre neuropathy (CNFD). The diagnostic efficacy of the continuous Neuropad output for abnormal DB-HRV (AUC: 91%,) and CNFD (AUC: 82%,) was better than for PMNCV (AUC: 60%). The categorical output showed no significant difference in diagnostic efficacy for these same measures. An image analysis algorithm generating a continuous output (Sudometrics) improved the diagnostic ability of Neuropad, particularly in detecting autonomic and small fibre neuropathy.- 1 January 2015
- Published by Wiley in Journal of Diabetes Research
- Vol. 2015, 1-7
Open AccessAutomated Quantification of Neuropad Improves Its Diagnostic Ability in Patients with Diabetic Neuropathy
Neuropad is currently a categorical visual screening test that identifies diabetic patients at risk of foot ulceration. The diagnostic performance of Neuropad was compared between the categorical and continuous (image-analysis (Sudometrics)) outputs to diagnose diabetic peripheral neuropathy (DPN). 110 subjects with type 1 and 2 diabetes underwent assessment with Neuropad, Neuropathy Disability Score (NDS), peroneal motor nerve conduction velocity (PMNCV), sural nerve action potential (SNAP), Deep Breathing-Heart Rate Variability (DB-HRV), intraepidermal nerve fibre density (IENFD), and corneal confocal microscopy (CCM). 46/110 patients had DPN according to the Toronto consensus. The continuous output displayed high sensitivity and specificity for DB-HRV (91%, 83%), CNFD (88%, 78%), and SNAP (88%, 83%), whereas the categorical output showed high sensitivity but low specificity. The optimal cut-off points were 90% for the detection of autonomic dysfunction (DB-HRV) and 80% for small fibre neuropathy (CNFD). The diagnostic efficacy of the continuous Neuropad output for abnormal DB-HRV (AUC: 91%,) and CNFD (AUC: 82%,) was better than for PMNCV (AUC: 60%). The categorical output showed no significant difference in diagnostic efficacy for these same measures. An image analysis algorithm generating a continuous output (Sudometrics) improved the diagnostic ability of Neuropad, particularly in detecting autonomic and small fibre neuropathy. - Top Cited PapersOpen Access
- 1 April 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (4) , 2071-2078
Rapid Automated Diagnosis of Diabetic Peripheral Neuropathy With In Vivo Corneal Confocal Microscopy
Purpose.: To assess the diagnostic validity of a fully automated image analysis algorithm of in vivo confocal microscopy images in quantifying corneal subbasal nerves to diagnose diabetic neuropathy. Methods.: One hundred eighty-six patients with type 1 and type 2 diabetes mellitus (T1/T2DM) and 55 age-matched controls underwent assessment of neuropathy and bilateral in vivo corneal confocal microscopy (IVCCM). Corneal nerve fiber density (CNFD), branch density (CNBD), and length (CNFL) were quantified with expert, manual, and fully-automated analysis. The areas under the curve (AUC), odds ratios (OR), and optimal thresholds to rule out neuropathy were estimated for both analysis methods. Results.: Neuropathy was detected in 53% of patients with diabetes. A significant reduction in manual and automated CNBD (P < 0.001) and CNFD (P < 0.0001), and CNFL (P < 0.0001) occurred with increasing neuropathic severity. Manual and automated analysis methods were highly correlated for CNFD (r = 0.9, P < 0.0001), CNFL (r = 0.89, P < 0.0001), and CNBD (r = 0.75, P < 0.0001). Manual CNFD and automated CNFL were associated with the highest AUC, sensitivity/specificity and OR to rule out neuropathy. Conclusions.: Diabetic peripheral neuropathy is associated with significant corneal nerve loss detected with IVCCM. Fully automated corneal nerve quantification provides an objective and reproducible means to detect human diabetic neuropathy.
- 1 April 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (4) , 2071-2078
Top Cited PapersOpen AccessRapid Automated Diagnosis of Diabetic Peripheral Neuropathy With In Vivo Corneal Confocal Microscopy
Purpose.: To assess the diagnostic validity of a fully automated image analysis algorithm of in vivo confocal microscopy images in quantifying corneal subbasal nerves to diagnose diabetic neuropathy. Methods.: One hundred eighty-six patients with type 1 and type 2 diabetes mellitus (T1/T2DM) and 55 age-matched controls underwent assessment of neuropathy and bilateral in vivo corneal confocal microscopy (IVCCM). Corneal nerve fiber density (CNFD), branch density (CNBD), and length (CNFL) were quantified with expert, manual, and fully-automated analysis. The areas under the curve (AUC), odds ratios (OR), and optimal thresholds to rule out neuropathy were estimated for both analysis methods. Results.: Neuropathy was detected in 53% of patients with diabetes. A significant reduction in manual and automated CNBD (P < 0.001) and CNFD (P < 0.0001), and CNFL (P < 0.0001) occurred with increasing neuropathic severity. Manual and automated analysis methods were highly correlated for CNFD (r = 0.9, P < 0.0001), CNFL (r = 0.89, P < 0.0001), and CNBD (r = 0.75, P < 0.0001). Manual CNFD and automated CNFL were associated with the highest AUC, sensitivity/specificity and OR to rule out neuropathy. Conclusions.: Diabetic peripheral neuropathy is associated with significant corneal nerve loss detected with IVCCM. Fully automated corneal nerve quantification provides an objective and reproducible means to detect human diabetic neuropathy.
- 21 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9034, 903415
Detection and location of 127 anatomical landmarks in diverse CT datasets
The automatic detection and localization of anatomical landmarks has wide application, including intra and interpatient registration, study location and navigation, and the targeting of specialized algorithms. In this paper, we demonstrate the automatic detection and localization of 127 anatomically defined landmarks distributed throughout the body, excluding arms. Landmarks are defined on the skeleton, vasculature and major organs. Our approach builds on the classification forests method,1 using this classifier with simple image features which can be efficiently computed. For the training and validation of the method we have used 369 CT volumes on which radiographers and anatomists have marked ground truth (GT) - that is the locations of all defined landmarks occurring in that volume. A particular challenge is to deal with the wide diversity of datasets encountered in radiology practice. These include data from all major scanner manufacturers, different extents covering single and multiple body compartments, truncated cardiac acquisitions, with and without contrast. Cases with stents and catheters are also represented. Validation is by a leave-one-out method, which we show can be efficiently implemented in the context of decision forest methods. Mean location accuracy of detected landmarks is 13.45mm overall; execution time averages 7s per volume on a modern server machine. We also present localization ROC analysis to characterize detection accuracy - that is to decide if a landmark is or is not present in a given dataset.
- 21 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9034, 903415
Detection and location of 127 anatomical landmarks in diverse CT datasets
The automatic detection and localization of anatomical landmarks has wide application, including intra and interpatient registration, study location and navigation, and the targeting of specialized algorithms. In this paper, we demonstrate the automatic detection and localization of 127 anatomically defined landmarks distributed throughout the body, excluding arms. Landmarks are defined on the skeleton, vasculature and major organs. Our approach builds on the classification forests method,1 using this classifier with simple image features which can be efficiently computed. For the training and validation of the method we have used 369 CT volumes on which radiographers and anatomists have marked ground truth (GT) - that is the locations of all defined landmarks occurring in that volume. A particular challenge is to deal with the wide diversity of datasets encountered in radiology practice. These include data from all major scanner manufacturers, different extents covering single and multiple body compartments, truncated cardiac acquisitions, with and without contrast. Cases with stents and catheters are also represented. Validation is by a leave-one-out method, which we show can be efficiently implemented in the context of decision forest methods. Mean location accuracy of detected landmarks is 13.45mm overall; execution time averages 7s per volume on a modern server machine. We also present localization ROC analysis to characterize detection accuracy - that is to decide if a landmark is or is not present in a given dataset.
- 1 May 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (5) , e83-e89
Repeatability of In Vivo Corneal Confocal Microscopy to Quantify Corneal Nerve Morphology
Purpose: To establish intraobserver and interobserver repeatability, agreement, and symmetry of corneal nerve fiber (NF) morphology in healthy subjects using in vivo corneal confocal microscopy. Methods: Nineteen subjects underwent in vivo corneal confocal microscopy (Heidelberg Retinal Tomograph III Rostock Cornea Module) at baseline and 7 days apart. Bland–Altman plots were generated to assess agreement, and the intraclass correlation coefficient and coefficient of repeatability were calculated to estimate intraobserver and interobserver repeatability for corneal NF density (numbers per square millimeter), nerve branch density (NBD; numbers per square millimeter), NF length (millimeters per square millimeter), and NF tortuosity coefficient. Symmetry between the right and left eyes was also assessed. Results: Intraclass correlation coefficient and coefficient of repeatability for intraobserver repeatability were 0.66 to 0.74 and 0.17 to 0.64, for interobserver repeatability 0.54 to 0.93 and 0.15 to 0.85, and for symmetry 0.34 to 0.77 and 0.17 to 0.63, respectively. NBD demonstrated low repeatability. Conclusions: This study demonstrates good repeatability for the manual assessment of all major corneal NF parameters with the exception of NBD, which highlights the difficulty in defining nerve branches and suggests the need for experienced observers or automated image analysis to ensure optimal repeatability.
- 1 May 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (5) , e83-e89
Repeatability of In Vivo Corneal Confocal Microscopy to Quantify Corneal Nerve Morphology
Purpose: To establish intraobserver and interobserver repeatability, agreement, and symmetry of corneal nerve fiber (NF) morphology in healthy subjects using in vivo corneal confocal microscopy. Methods: Nineteen subjects underwent in vivo corneal confocal microscopy (Heidelberg Retinal Tomograph III Rostock Cornea Module) at baseline and 7 days apart. Bland–Altman plots were generated to assess agreement, and the intraclass correlation coefficient and coefficient of repeatability were calculated to estimate intraobserver and interobserver repeatability for corneal NF density (numbers per square millimeter), nerve branch density (NBD; numbers per square millimeter), NF length (millimeters per square millimeter), and NF tortuosity coefficient. Symmetry between the right and left eyes was also assessed. Results: Intraclass correlation coefficient and coefficient of repeatability for intraobserver repeatability were 0.66 to 0.74 and 0.17 to 0.64, for interobserver repeatability 0.54 to 0.93 and 0.15 to 0.85, and for symmetry 0.34 to 0.77 and 0.17 to 0.63, respectively. NBD demonstrated low repeatability. Conclusions: This study demonstrates good repeatability for the manual assessment of all major corneal NF parameters with the exception of NBD, which highlights the difficulty in defining nerve branches and suggests the need for experienced observers or automated image analysis to ensure optimal repeatability.
- Top Cited Papers
- 1 October 2011
- Published by Elsevier in Medical Image Analysis
- Vol. 15 (5) , 738-747
Automatic analysis of diabetic peripheral neuropathy using multi-scale quantitative morphology of nerve fibres in corneal confocal microscopy imaging
- 1 October 2011
- Published by Elsevier in Medical Image Analysis
- Vol. 15 (5) , 738-747
Top Cited PapersAutomatic analysis of diabetic peripheral neuropathy using multi-scale quantitative morphology of nerve fibres in corneal confocal microscopy imaging
- 15 June 2011
- Published by Springer Nature
- p. 145-166
Detecting and Analyzing Linear Structures in Biomedical Images: A Case Study Using Corneal Nerve Fibers
- 15 June 2011
- Published by Springer Nature
- p. 145-166
Detecting and Analyzing Linear Structures in Biomedical Images: A Case Study Using Corneal Nerve Fibers