Reducing contamination while closing the gap: BASSI RF pulses in PASL
Open Access
- 9 March 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (4) , 865-873
Abstract
Bandwidth‐modulated selective saturation and inversion (BASSI) pulses are a class of frequency‐ and gradient‐modulated radiofrequency (RF) pulses, derived from the hyperbolic secant pulse by temporal variation of the bandwidth parameter. These pulses afford optimal amplitude modulation, achieving uniform and highly selective profiles at any effective flip angle. In this paper, BASSI pulses are parameterized to obtain low RF energy pulsed arterial spin labeling (PASL) label pulses with minimal contamination of static spins outside the label region and highly selective PICORE/QUIPSS II saturation pulses allowing for small label gaps. They are compared to frequency offset corrected inversion (FOCI) label pulses and sinc saturation pulses in simulations and a phantom experiment. Drawing on the outstanding selectivity of bandwidth‐modulated saturation pulses, a new noninvasive method to measure in vivo the contamination effects due to direct and indirect saturation of static spins by the label pulse is presented. In an in vivo study on four subjects, contamination effects in a QUIPSS II PASL implementation based on BASSI pulses are compared to those present in a state‐of‐the‐art Q2TIPS sequence employing a FOCI label pulse. Residual contamination in the QUIPSS II/BASSI sequence is shown to be reduced by a factor of 3, compared to the Q2TIPS/FOCI sequence. In vivo human perfusion images obtained with a label gap of only 2 mm are presented. Magn Reson Med, 2006.Keywords
This publication has 28 references indexed in Scilit:
- Bandwidth‐modulated adiabatic RF pulses for uniform selective saturation and inversionMagnetic Resonance in Medicine, 2004
- New FOCI pulses with reduced radiofrequency power requirementsJournal of Magnetic Resonance Imaging, 2004
- Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopyMagnetic Resonance in Medicine, 1996
- AFNI: Software for Analysis and Visualization of Functional Magnetic Resonance NeuroimagesComputers and Biomedical Research, 1996
- A Model for Quantification of Perfusion in Pulsed Labelling TechniquesNMR in Biomedicine, 1996
- Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection sliceMagnetic Resonance in Medicine, 1996
- A reduced power selective adiabatic spin‐echo pulse sequenceMagnetic Resonance in Medicine, 1991
- Variable-rate selective excitationJournal of Magnetic Resonance (1969), 1988
- Two-state problems involving arbitrary amplitude and frequency modulationsPhysical Review A, 1985
- Highly selective and π pulse generationJournal of Magnetic Resonance (1969), 1984