Jan M. Warnking
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jan M. Warnking has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Gilbert Bruce Pike
University of Calgary
2 shared publications
Latest Publications
- Open Access
- 9 March 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (4) , 865-873
Reducing contamination while closing the gap: BASSI RF pulses in PASL
Bandwidth‐modulated selective saturation and inversion (BASSI) pulses are a class of frequency‐ and gradient‐modulated radiofrequency (RF) pulses, derived from the hyperbolic secant pulse by temporal variation of the bandwidth parameter. These pulses afford optimal amplitude modulation, achieving uniform and highly selective profiles at any effective flip angle. In this paper, BASSI pulses are parameterized to obtain low RF energy pulsed arterial spin labeling (PASL) label pulses with minimal contamination of static spins outside the label region and highly selective PICORE/QUIPSS II saturation pulses allowing for small label gaps. They are compared to frequency offset corrected inversion (FOCI) label pulses and sinc saturation pulses in simulations and a phantom experiment. Drawing on the outstanding selectivity of bandwidth‐modulated saturation pulses, a new noninvasive method to measure in vivo the contamination effects due to direct and indirect saturation of static spins by the label pulse is presented. In an in vivo study on four subjects, contamination effects in a QUIPSS II PASL implementation based on BASSI pulses are compared to those present in a state‐of‐the‐art Q2TIPS sequence employing a FOCI label pulse. Residual contamination in the QUIPSS II/BASSI sequence is shown to be reduced by a factor of 3, compared to the Q2TIPS/FOCI sequence. In vivo human perfusion images obtained with a label gap of only 2 mm are presented. Magn Reson Med, 2006.
- 9 March 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (4) , 865-873
Open AccessReducing contamination while closing the gap: BASSI RF pulses in PASL
Bandwidth‐modulated selective saturation and inversion (BASSI) pulses are a class of frequency‐ and gradient‐modulated radiofrequency (RF) pulses, derived from the hyperbolic secant pulse by temporal variation of the bandwidth parameter. These pulses afford optimal amplitude modulation, achieving uniform and highly selective profiles at any effective flip angle. In this paper, BASSI pulses are parameterized to obtain low RF energy pulsed arterial spin labeling (PASL) label pulses with minimal contamination of static spins outside the label region and highly selective PICORE/QUIPSS II saturation pulses allowing for small label gaps. They are compared to frequency offset corrected inversion (FOCI) label pulses and sinc saturation pulses in simulations and a phantom experiment. Drawing on the outstanding selectivity of bandwidth‐modulated saturation pulses, a new noninvasive method to measure in vivo the contamination effects due to direct and indirect saturation of static spins by the label pulse is presented. In an in vivo study on four subjects, contamination effects in a QUIPSS II PASL implementation based on BASSI pulses are compared to those present in a state‐of‐the‐art Q2TIPS sequence employing a FOCI label pulse. Residual contamination in the QUIPSS II/BASSI sequence is shown to be reduced by a factor of 3, compared to the Q2TIPS/FOCI sequence. In vivo human perfusion images obtained with a label gap of only 2 mm are presented. Magn Reson Med, 2006.
- Open Access
- 26 October 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1190-1199
Bandwidth‐modulated adiabatic RF pulses for uniform selective saturation and inversion
Radiofrequency (RF) inversion and saturation pulses with extremely high spatial selectivity and uniform profiles are a requirement for numerous MR techniques, such as pulsed arterial spin labeling and outer volume suppression. Adiabatic pulses used for inversion of longitudinal magnetization are ubiquitous, but the superior selectivity of adiabatic full passages has not been widely exploited for saturation because a simple way of calibrating the amplitude of these subadiabatic pulses is lacking. An analytically derived calibration equation is presented, applicable to a large class of pulses including the hyperbolic secant (HS) pulse and allowing the determination of the precise amplitude required to achieve any effective flip angle. The properties of this calibration are examined, and a highly selective and homogeneous HS saturation pulse is demonstrated. Based on this calibration a new class of RF pulses is developed. These bandwidth-modulated adiabatic selective saturation and inversion (BASSI) RF pulses afford optimal amplitude modulation, achieving uniform profiles at any effective flip angle. BASSI pulses are compared to existing gradient modulated adiabatic pulses in simulations and phantom experiments and shown to be superior in terms of selectivity and homogeneity, while requiring less RF energy. An application of BASSI pulses to pulsed arterial spin labeling is shown. Magn Reson Med 52:1190–1199, 2004.
- 26 October 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (5) , 1190-1199
Open AccessBandwidth‐modulated adiabatic RF pulses for uniform selective saturation and inversion
Radiofrequency (RF) inversion and saturation pulses with extremely high spatial selectivity and uniform profiles are a requirement for numerous MR techniques, such as pulsed arterial spin labeling and outer volume suppression. Adiabatic pulses used for inversion of longitudinal magnetization are ubiquitous, but the superior selectivity of adiabatic full passages has not been widely exploited for saturation because a simple way of calibrating the amplitude of these subadiabatic pulses is lacking. An analytically derived calibration equation is presented, applicable to a large class of pulses including the hyperbolic secant (HS) pulse and allowing the determination of the precise amplitude required to achieve any effective flip angle. The properties of this calibration are examined, and a highly selective and homogeneous HS saturation pulse is demonstrated. Based on this calibration a new class of RF pulses is developed. These bandwidth-modulated adiabatic selective saturation and inversion (BASSI) RF pulses afford optimal amplitude modulation, achieving uniform profiles at any effective flip angle. BASSI pulses are compared to existing gradient modulated adiabatic pulses in simulations and phantom experiments and shown to be superior in terms of selectivity and homogeneity, while requiring less RF energy. An application of BASSI pulses to pulsed arterial spin labeling is shown. Magn Reson Med 52:1190–1199, 2004.