Two-Dimensional FAIMS-TIMS Separation for Probing Structural Diversity of Peptides with Resolution Exceeding 6500
- 21 October 2025
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (43) , 24225-24231
Abstract
A two-dimensional gas-phase ion separation platform was developed by coupling high-sensitivity and high-resolution racetrack field asymmetric waveform ion mobility spectrometry (r-FAIMS) with trapped ion mobility spectrometry (TIMS) and time-of-flight mass spectrometry. This platform was applied to explore the conformational diversity of doubly charged bradykinin (BK+2H+)2+ ions. Four conformers of the (BK+2H+)2+ ion can be resolved by using fully optimized TIMS, while six conformers of the (BK+2H+)2+ ion with different compensation voltages (CV) can be resolved by using r-FAIMS with pure nitrogen as a carrier gas and a 2.6 kV dispersion voltage (DV). By further TIMS analyses of the CV-selected (BK+2H+)2+ ions corresponding to all the six FAIMS separated peaks, nearly 30 conformers of the (BK+2H+)2+ ion can be resolved. Multiple conformers of (BK+2H+)2+ ions were found to have completely different CV values, although their mobilities were essentially the same. Multiple TIMS peaks, which are basically buried in the ambient noise in the normal TIMS spectrum, can be easily detected in the CV-selected TIMS spectra. These experimental measurements have positively proven that the separations in the FAIMS and TIMS dimensions are highly orthogonal. The overall resolving power of two-dimensional r-FAIMS-TIMS separation is essentially proportional to the product of the resolving powers of r-FAIMS and TIMS. The theoretical calculation, based on the data correlation between FAIMS and TIMS measurements, has shown that the total resolving power of the combined r-FAIMS and TIMS separation exceeds 6500 for the (BK+2H+)2+ ions, making the new instrument platform very effective for the structural elucidation of large biomolecules.Keywords
Funding Information
- National Key Research and Development Program of China (2023YFC3304203)
- K. C. Wong Magna Fund in Ningbo University (xkzwl1507)
- Key Research and Development Program of Zhejiang Province (2024C03101, 2024C03266, 2025C01200(SD2))
- Ningbo Science and Technology Project (2022Z241, 2023S151, 2023Z132, 2023Z168, 2024S047, 2024Z230)
- Hangzhou Science and Technology Development Project (20231203A18)
- Yangtze River Delta Science and Technology Innovation Community Joint Research Project (2023CSJGG1800)
This publication has 29 references indexed in Scilit:
- Simulation study of a new racetrack FAIMS analyzer to achieve both high-resolution and high-sensitivityTalanta, 2024
- Two‐step particle swarm optimization algorithm for effective deconvolution and resolution enhancement of various overlapping peaksRapid Communications in Mass Spectrometry, 2022
- Application of zero‐phase digital filtering for effective denoising of field asymmetric waveform ion mobility spectrometry signalRapid Communications in Mass Spectrometry, 2021
- Effective separation of carbohydrate isomers using metal cation and halogen anion complexes in trapped ion mobility spectrometryTalanta, 2021
- Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road AheadJournal of the American Society for Mass Spectrometry, 2019
- Fundamentals of Trapped Ion Mobility SpectrometryJournal of the American Society for Mass Spectrometry, 2014
- Separation and Classification of Lipids Using Differential Ion Mobility SpectrometryJournal of the American Society for Mass Spectrometry, 2011
- Differential mobility spectrometer: Model of operationInternational Journal of Mass Spectrometry, 2007
- Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometryJournal of the American Society for Mass Spectrometry, 2000
- Pearson's correlation coefficient, p-value, and lithium therapyBiological Psychiatry, 1987