JLJunhui Li

Junhui Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junhui Li has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Jiancheng Yu

    Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application Ningbo University Ningbo China

    12 shared publications
  • Chenlu Wang

    Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application Ningbo University Ningbo China

    9 shared publications
  • Keqi Tang

    Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application. Institute of Mass Spectrometry, School of Materials Science & Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China

    9 shared publications
  • Keqi Tang

    Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass spectrometry and Clinical Application

    8 shared publications
  • Rong Liu

    Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass spectrometry and Clinical Application, Ningbo University, Ningbo 315211, PR China; Zhenhai Institute of Mass Spectrometry, Ningbo 315211, PR China; School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, PR China

    6 shared publications
  • Wenqing Gao

    Ningbo Univ, Inst Mass Spectrometry, Zhejiang Engn Res Ctr Adv Mass Spectrometry & Clin, Ningbo 315211, Peoples R China

    6 shared publications

Latest Publications

  • Multiparameter Simulation for the Optimization of Ion Transmission Efficiency Through Mass Spectrometry Inlet Capillary

    by Di Wang, Chenlu Wang, Junhui Li, Jiancheng Yu, Keqi Tang

    Rationale: According to the mass spectrometry (MS) design principles, the ions generated in an atmospheric pressure ion source must pass through a narrow‐bore capillary in order to maintain the needed system vacuum pressure. The ion transmission efficiency through the inlet capillary is one of the key factors directly influencing the analytical performance of MS. Its design and operating parameters, including inner diameter, length, temperature, and those related to the ion source operation, can alter ion diffusion losses, gas flow dynamics, and space‐charge effects both around and inside the inlet capillary, thereby influencing ion sampling efficiency and transmission efficiency to the mass analyzer. Methods: A comprehensive simulation of ion transmission efficiency through an MS inlet capillary has been performed in this study by adjusting the important design and operating parameters. Results: The simulation results show that the ion transmission efficiency through the inlet capillary is positively correlated with the inner diameter of the capillary and negatively correlated with the length of the capillary. Specifically, under the conditions of a capillary diameter of 0.8 mm and a temperature of 573.15 K, the ion transmission efficiency through a 10‐cm‐long capillary can reach 90%. The efficiency decreases with a reduction in the inner diameter or an increase in the length. When the temperature exceeds 573.15 K, the flow field inside the capillary transits from laminar to turbulent flow, leading to a sharp decline in ion transmission efficiency. For every 100‐K increase in temperature beyond this point, the ion transmission efficiency decreases by 10%–20%. Conclusions: The main results from this study have provided crucial design guidelines, emphasizing the use of larger diameters, moderate lengths, and strict temperature control below the turbulent transition threshold to maximize ion transmission and overall instrument sensitivity for MS instruments.

  • FAIMS-IMS-QTOF MS Combined with TSPSO Deconvolution Algorithm for Effectively Probing Protein Conformation Changes Induced by Dipole Locking in FAIMS

    by Kaiqun Wu, Rong Liu, Zhonghan Hu, Yong Wu, Chenlu Wang, Junhui Li, Jiancheng Yu, Keqi Tang

    Carbonic anhydrase (CA), a ∼29 kDa large protein, was systematically analyzed by using an r-FAIMS-IMS-QTOF MS system to probe the conformational changes induced by dipole locking in FAIMS. By operating the r-FAIMS in different modes (i.e., different voltage polarities), one dipole-locked and two unlocked CA FAIMS peaks were discovered for some charge states of the CA ions. Further IMS analyses for various charge state CA ions from different FAIMS peaks showed that the drift times for some of the same charge-state CA ions from dipole-locked and unlocked FAIMS peaks were completely different, implying different CA conformers. For some of the same charge-state CA ions, essentially the same drift times from the dipole-locked and unlocked FAIMS peaks were observed. These CA ions were further subjected to ion fragmentation (MS/MS) analyses in QTOF-MS. The product ion spectra for these CA ions were shown to be highly different under the same MS/MS operation conditions. These experimental results have positively confirmed that the same charge-state CA ions from dipole-locked and unlocked FAIMS peaks indeed represent different conformers. To achieve accurate IMS spectral analyses, all IMS overlapping peaks were deconvoluted by using a high-accuracy deconvolution algorithm (two-step particle swarm optimization algorithm, TSPSO). The r-FAIMS-IMS-QTOF MS system, combined with the TSPSO deconvolution algorithm developed through this study, can be a powerful platform for the structural elucidation of large biomolecules.

  • A fully automated high-throughput system for simultaneously enriching and separating intact glycopeptides

    by Zhonghan Hu, Rong Liu, Junhui Li, Chenlu Wang, Hongxia Wang, Jiancheng Yu, Keqi Tang

  • Tandem FAIMS and IMS Combined with MS/MS for Effectively Probing the Structural Diversity of Proteins

    by Kaiqun Wu, Rong Liu, Zhonghan Hu, Chenlu Wang, Junhui Li, Jiancheng Yu, Keqi Tang

    A three-dimensional gas-phase ion separation instrument platform that integrates high-sensitivity and high-resolution racetrack field asymmetric waveform ion mobility spectrometry (r-FAIMS) with quadrupole time-of-flight mass spectrometry (Agilent 6560 IMS-QTOF MS) was developed to probe the conformational diversity of cytochrome C ions. A charge state envelope of +8 to +19 for the cytochrome C ions was observed in the acquired MS spectrum. For the +8 to +11 charge states of cytochrome C ions, multiple peaks were clearly observed in the IMS spectra, while only one peak was observed in the corresponding FAIMS spectra. In contrast, well-separated multiple peaks were clearly observed for the +13 to +19 charge states of cytochrome C ions in the FAIMS spectra. However, the ions from different FAIMS peaks were shown to have very close drift times in the second dimension IMS measurements, implying that these ions had essentially the same collisional cross-sectional areas. To verify these FAIMS peaks, corresponding to different compensation voltages, for the +13 to +19 charge states of cytochrome C ions indeed represent different protein conformers. The CV-selected cytochrome C ions were further subjected to ion fragmentation (MS/MS) analysis in the third dimension QTOF MS. MS/MS analyses have clearly demonstrated that the product ion spectra for the same charge state of cytochrome C ions from different FAIMS CV peaks are highly different under the same MS/MS operation conditions (i.e. under the same collision energy). The results from the MS/MS analyses thus convincingly prove that the protein ions from different FAIMS peaks are different conformers. Gas-phase ion separations in FAIMS and IMS are, thus, highly orthogonal. Unique to any other alternatives, the proposed r-FAIMS-IMS-MS/MS technique allows for a highly efficient FAIMS separation of protein structural isomers, detailed IMS measurements of the collisional cross-sectional area for each isomeric protein, and direct confirmation of isomeric proteins via MS/MS.


  • Two-Dimensional FAIMS-TIMS Separation for Probing Structural Diversity of Peptides with Resolution Exceeding 6500

    by Junhui Li, Xixuan Gu, Yongqi Lei, Kaiqun Wu, Zhonghan Hu, Rong Liu, Chenlu Wang, Yong Wu, Jiancheng Yu, Keqi Tang

    A two-dimensional gas-phase ion separation platform was developed by coupling high-sensitivity and high-resolution racetrack field asymmetric waveform ion mobility spectrometry (r-FAIMS) with trapped ion mobility spectrometry (TIMS) and time-of-flight mass spectrometry. This platform was applied to explore the conformational diversity of doubly charged bradykinin (BK+2H+)2+ ions. Four conformers of the (BK+2H+)2+ ion can be resolved by using fully optimized TIMS, while six conformers of the (BK+2H+)2+ ion with different compensation voltages (CV) can be resolved by using r-FAIMS with pure nitrogen as a carrier gas and a 2.6 kV dispersion voltage (DV). By further TIMS analyses of the CV-selected (BK+2H+)2+ ions corresponding to all the six FAIMS separated peaks, nearly 30 conformers of the (BK+2H+)2+ ion can be resolved. Multiple conformers of (BK+2H+)2+ ions were found to have completely different CV values, although their mobilities were essentially the same. Multiple TIMS peaks, which are basically buried in the ambient noise in the normal TIMS spectrum, can be easily detected in the CV-selected TIMS spectra. These experimental measurements have positively proven that the separations in the FAIMS and TIMS dimensions are highly orthogonal. The overall resolving power of two-dimensional r-FAIMS-TIMS separation is essentially proportional to the product of the resolving powers of r-FAIMS and TIMS. The theoretical calculation, based on the data correlation between FAIMS and TIMS measurements, has shown that the total resolving power of the combined r-FAIMS and TIMS separation exceeds 6500 for the (BK+2H+)2+ ions, making the new instrument platform very effective for the structural elucidation of large biomolecules.


  • Sequential Proteomic and N-Glycoproteomic Analyses of Bronchoalveolar Lavage Fluids for Potential Biomarker Discovery of Lung Adenocarcinoma

    by Rong Liu, Zhonghan Hu, Chenlu Wang, Junhui Li, Keqi Tang, Songping Yu

    Lung adenocarcinoma (LUAD) is the most common histological subtype of nonsmall-cell lung cancer. Herein, a multiomics method, which combined proteomic and N-glycoproteomic analyses, was developed to analyze the normal and cancerous bronchoalveolar lavage fluids (BALFs) from six LUAD patients to identify potential biomarkers of LUAD. The data-independent acquisition proteomic analysis was first used to analyze BALFs, which identified 59 differentially expressed proteins (DEPs). The bioinformatic analyses of 59 DEPs have shown that a potential marker protein, beta-1,4-galactosyltransferase 1 (B4GALT1), was consistently downregulated in all cancerous lung lobes (CLLs). As the downregulation of B4GALT1 may indicate changes in protein N-glycosylation, site-specific N-glycoproteome analysis of BALFs from the normal lung lobes (NLLs) and CLLs was further performed by using a fully automated glycopeptide enrichment and separation system. Comparing the glycan structures containing free GlcNAc in BALFs between NLLs and CLLs qualitatively, the percentage of unique glycan structure for free GlcNAc existing only in NLLs was 52.8%, which was significantly higher than the 46.3% existing only in CLLs. Furthermore, the sequential proteomic and N-glycoproteomic analyses allowed us to identify a panel of functionally related potential biomarkers consisting of one protein (B4GALT1) and four glycoproteins (NFKB1, F2, LTF, and DLD).


  • Capillary zone electrophoresis-tandem mass spectrometry for in-depth proteomics analysis via data-independent acquisition

    by Rong Liu, Gang Lu, Xiaozhong Hu, Junhui Li, Zhenbin Zhang, Keqi Tang

    A capillary zone electrophoresis (CZE) system was coupled to an Orbitrap mass spectrometer operating in a data-independent acquisition (DIA) mode for in-depth proteomics analysis. The performance of this CZE-DIA-MS system was systemically evaluated and optimized under different operating conditions. The performance of the fully optimized CZE-DIA-MS system was subsequently compared to the one by using the same CZE-MS system operating in a data-dependent acquisition (DDA) mode. The experimental results show that the numbers of identified peptides and proteins acquired in the DIA mode are much higher than the ones acquired in the DDA mode, especially with the small sample loading amount. Specifically, the numbers of identified peptides and proteins acquired in the DIA mode are 1.8-fold and 2-fold higher than the ones acquired in the DDA mode by using 12.5 ng Hela digests. The proteins identified in the DIA mode also cover almost all the proteins identified in the DDA mode. In addition, a potential cancer biomarker protein, carbohydrate antigen 125, undetected in the DDA mode, can be easily identified in the DIA mode even with 12.5 ng Hela digests. The performance of the CZE-DIA-MS system for in-depth proteomics analysis with a limited sample amount has been fully demonstrated for the first time through this study. Graphical Abstract


  • Racetrack FAIMS for High-Resolution and High-Sensitivity Characterization of Peptide Conformers

    by Junhui Li, Rong Liu, Zhonghan Hu, Shoushuai Fu, Jiancheng Yu, Keqi Tang

    A racetrack field asymmetric waveform ion mobility spectrometry (r-FAIMS) device, which consists of both cylindrical FAIMS (c-FAIMS) and planar FAIMS (p-FAIMS) sections with a 1 mm gap width, was developed and applied for high-resolution and high-sensitivity exploration of conformational diversity for peptides. The optimal operating conditions of r-FAIMS were systemically studied, and the performance of the fully optimized r-FAIMS was compared to a previously developed p-FAIMS in detail by using pure nitrogen as the FAIMS carrier gas. Relying on the ion focusing effect in the c-FAIMS section, the intensity of the FAIMS spectrum for doubly charged bradykinin ions acquired by using r-FAIMS is ∼8.5-fold higher than that acquired by using p-FAIMS under the same resolving power/resolution condition, implying about an order of magnitude better sensitivity of r-FAIMS. In addition, the peak separation resolution of r-FAIMS was ∼1.70-fold higher than p-FAIMS under a similar sensitivity condition for doubly charged bradykinin ions. Due to a reduced gap width of the newly designed r-FAIMS (1 mm) as compared to the previously developed p-FAIMS (1.88 mm), r-FAIMS can operate at a much higher separation field with a similar FAIMS dispersion voltage (DV) to gain significantly higher resolving power. For triply charged syntide 2 ions, the resolving power of r-FAIMS can easily exceed 120 at −3.5 kV DV by using pure nitrogen as the FAIMS carrier gas as compared to 44.2 resolving power obtained by using p-FAIMS at −4.0 kV DV. All of the experimental results have confirmed that r-FAIMS can perform structural characterization of biomolecules with both high resolution and high sensitivity.


  • An efficient strategy with a synergistic effect of hydrophilic and electrostatic interactions for simultaneous enrichment of N - and O -glycopeptides

    by Zhonghan Hu, Wenqing Gao, Rong Liu, Jiaqian Yang, Renlu Han, Junhui Li, Jiancheng Yu, Danhua Ma, Keqi Tang

    An efficient strategy was firstly proposed and successfully applied to simultaneous enrichment of N - and O -glycopeptides from complex biological samples through the synergistic effect of hydrophilic and electrostatic interactions.