Handling of lipemic samples in the clinical laboratory
Open Access
- 9 February 2023
- journal article
- review article
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 4 (1) , 5-15
Abstract
Interferences in the clinical laboratory may lead physicians misinterpret results for some biological analytes. The most common analytical interferences in the clinical laboratory include hemolysis, icterus and lipemia. Lipemia is defined as turbidity in a sample caused by the accumulation of lipoproteins, mainly very-low density lipoproteins (VLDL) and chylomicrons. Several methods are available for the detection of lipemic samples, including the lipemic index, or triglyceride quantification in serum or plasma samples, or mean corpuscular hemoglobin (MCHC) concentration in blood samples. According to the European Directive 98/79/CE, it is the responsibility of clinical laboratories to monitor the presence of interfering substances that may affect the measurement of an analyte. There is an urgent need to standardize interference studies and the way interferences are reported by manufacturers. Several methods are currently available to remove interference from lipemia and enable accurate measurement of biological quantities. The clinical laboratory should establish a protocol for the handling of lipemic samples according to the biological quantity to be tested.Keywords
This publication has 34 references indexed in Scilit:
- Effects of parenteral lipid emulsions on Leukocyte numerical and morphological parameters determined by LH750 hematology analyzerInternational Journal of Laboratory Hematology, 2013
- Hemolysis, Lipemia, and High Bilirubin2013
- Investigation of unusual high serum indices for lipemia in clear serum samples on Siemens analysers DimensionBiochemia Medica, 2012
- Chylothorax and Cholesterol Pleural EffusionSeminars in Respiratory and Critical Care Medicine, 2010
- Hiperglicerolemia, una seudohipertrigliceridemia: A propósito de un niño de 6 años de edadAnales de Pediatría, 2009
- Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytesInternational Journal of Laboratory Hematology, 2007
- Assay-Specific Differences in Lipemic Interference in Native and Intralipid-Supplemented SamplesClinical Chemistry, 2004
- Evaluating Interference Caused by LipemiaClinical Chemistry, 2004
- Unreliability of triglyceride measurement to predict turbidity induced interferenceJournal of Clinical Pathology, 2003
- Effects of Haemolysis, Lipaemia, Bilirubinaemia and Fibrinogen on Protein Electropherogram of Canine Samples Analysed by Capillary Zone ElectrophoresisThe Veterinary Journal, 2002