CFCarla Fernández-Prendes

Carla Fernández-Prendes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carla Fernández-Prendes has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Algorithm for Detecting Monoclonal IgM in Patients with an Elevated Lipemia Index Using the Beckman Coulter AU5800 Analyzer

    by Álvaro Piedra-Aguilera, Carla Fernández-Prendes, Susana Malumbres-Serrano, Laura Abril-Sabater, Albert Oriol-Rocafiguera, Cristian Morales-Indiano

    Álvaro Piedra-Aguilera, Ph.D., Carla Fernández-Prendes, B.Sc., Susana Malumbres-Serrano, B.Sc., Laura Abril-Sabater, M.D., Albert Oriol-Rocafiguera, M.D., Ph.D., and Cristian Morales-Indiano, Ph.D.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2025.0456

  • Open Access

    Aspectos fundamentales en la solicitud y determinación de la lipoproteína(a) en el laboratorio clínico

    by Teresa Arrobas Velilla, Carla Fernández Prendes, Núria Amigó Grau, Pilar Calmarza, Silvia Camós Anguila, Beatriz Candas Estébanez, María José Castro Castro, David Ceacero, Irene González Martínez, María Martín Palencia, et al.

    Resumen: Las enfermedades cardiovasculares continúan siendo la principal causa de muerte en España, lo que sugiere la necesidad de estudiar la presencia de nuevos factores de riesgo que puedan estar contribuyendo a aumentar el riesgo cardiovascular. La lipoproteína(a) (Lp(a)) se ha asociado con un mayor riesgo de desarrollar estenosis valvular aórtica, insuficiencia cardíaca, ictus isquémico, cardiopatía isquémica y enfermedad arterial periférica. La hiperlipoproteinemia(a) es un problema de salud generalizado. Entre el 10 % y el 30 % de la población mundial presenta valores de Lp(a) superiores a 50 mg/dL. La evidencia científica acumulada en los últimos años ha confirmado la existencia de una asociación independiente entre la concentración de Lp(a) y el riesgo de presentar un evento cardiovascular arteriosclerótico. Este hallazgo, unido al creciente desarrollo de nuevas terapias específicas para reducir la Lp(a), ha incrementado notablemente el interés por su medición. El objetivo de este documento es, en base a la evidencia actual, informar sobre a qué pacientes se debería medir la Lp(a), cuáles son los métodos de medición recomendados, las concentraciones deseables y la utilidad de su medición en la reclasificación de pacientes según su riesgo cardiovascular.

  • Open Access

    Fundamentals of lipoprotein(a) request and quantification in the clinical laboratory

    by Teresa Arrobas Velilla, Carla Fernández Prendes, Núria Amigó Grau, Pilar Calmarza, Silvia Camós Anguila, Beatriz Candas Estébanez, María José Castro Castro, David Ceacero, Irene González Martínez, María Martín Palencia, et al.

    Cardiovascular diseases keep being the leading cause of mortality in Spain. Efforts should be intensified to identify new risk factors that may contribute to increasing cardiovascular risk. Lipoprotein(a) (Lp(a)) has been associated with a higher risk for developing aortic valve stenosis, heart failure, ischemic stroke, ischemic heart disease and peripheral arterial disease. Hyperlipoproteinemia(a) is a common health problem. Between 10 and 30 % of the world population have Lp(a) values exceeding 50 mg/dL. The scientific evidence provided in the recent years confirms an independent association between Lp(a) and the risk for having an arteriosclerotic cardiovascular event. This finding, added to the emergence of new specific therapies for reducing Lp(a) has raised interest in the quantification of this lipoprotein. The objective of this paper was to perform a review of the evidence available to identify the patients who will benefit from undergoing Lp(a) testing and determine the recommended quantification methods, the desirable concentrations, and the role of Lp(a) determination in reclassifying the cardiovascular risk of patients.


  • Open Access

    Direct LDL Cholesterol Assay vs. Estimated Equations in Patients With Hypertriglyceridemia or Low LDL Cholesterol Levels

    by Jennifer Rodríguez-Domínguez, Álvaro Piedra-Aguilera, María Martínez-Bujidos, Susana Malumbres-Serrano, Cristian Morales-Indiano, Carla Fernández-Prendes

    Jennifer Rodríguez-Domínguez, RD.J., Álvaro Piedra-Aguilera, PA.A., María Martínez-Bujidos, MB.M., Susana Malumbres-Serrano, MS.S., Cristian Morales-Indiano, MI.C., and Carla Fernández-Prendes, FP.C.. Ann Lab Med 2024;44:363-6. https://doi.org/10.3343/alm.2023.0387


    • 18 April 2023
      • Vol. 34  (1) , 27-41
    Open Access

    Discrepancies in Lipemia Interference Between Endogenous Lipemic Samples and Smoflipid®-Supplemented Samples

    by Carla Fernández-Prendes, Maria-José Castro-Castro, Laura Jiménez-Añón, Cristian Morales-Indiano, María Martínez-Bujidos

    Manufacturers evaluate lipemia-induced interference using Intralipid®, but it does not contain all lipoprotein types. The aim of this study was to evaluate lipemiainduced interference in biochemical parameters from endogenous lipemic samples and SMOFlipid® supplemented samples, in order to assess if SMOFlipid® can be used in lipemic interference studies. Serum pools were supplemented with SMOFlipid® to achieve 800 mg/dL and 1500 mg/dL triglyceride concentration, and analyzed for 25 biochemical parameters both before and after the supplementation. In another independent phase, lipemic serum pools were prepared choosing patient samples of 800 mg/dL and 1500 mg/dL triglyceride concentration. These lipemic serum pools were ultracentrifugated in order to remove lipids. Biochemical parameters were analyzed before and after ultracentrifugation. The bias between SMOFlipid®-supplemented samples and endogenous lipemic samples were compared. The bias between the lipemic and non-lipemic samples were compared with the reference change value. At 800 mg/dL triglyceride concentration, we found that total protein and transferrin had been affected only in endogenous lipemic serum samples. Magnesium and creatinine had been affected only in SMOFlipid®-supplemented samples. At 1500 mg/dL triglyceride concentration, we found that total protein, amylase, ferritin and glucose had lipemic interference only in endogenous lipemic samples, and chloride only in SMOFlipid®-supplemented samples. The use of SMOFlipid®-supplemented samples does not provide suitable data to estimate lipemia-induced interference. Thus, interference studies should be performed using a wide variety of lipemic patient samples that represent the heterogeneity of the lipoprotein particles size.


  • Open Access

    Handling of lipemic samples in the clinical laboratory

    by Carla Fernández Prendes, María José Castro Castro, Lourdes Sánchez Navarro, Loreto Rapún Mas, Cristian Morales Indiano, Teresa Arrobas Velilla

    Interferences in the clinical laboratory may lead physicians misinterpret results for some biological analytes. The most common analytical interferences in the clinical laboratory include hemolysis, icterus and lipemia. Lipemia is defined as turbidity in a sample caused by the accumulation of lipoproteins, mainly very-low density lipoproteins (VLDL) and chylomicrons. Several methods are available for the detection of lipemic samples, including the lipemic index, or triglyceride quantification in serum or plasma samples, or mean corpuscular hemoglobin (MCHC) concentration in blood samples. According to the European Directive 98/79/CE, it is the responsibility of clinical laboratories to monitor the presence of interfering substances that may affect the measurement of an analyte. There is an urgent need to standardize interference studies and the way interferences are reported by manufacturers. Several methods are currently available to remove interference from lipemia and enable accurate measurement of biological quantities. The clinical laboratory should establish a protocol for the handling of lipemic samples according to the biological quantity to be tested.


  • Open Access

    Manejo de muestras lipémicas en el Laboratorio Clínico

    by Carla Fernández-Prendes, María J. Castro Castro, Lourdes Sánchez Navarro, Loreto Rapún Mas, Cristian Morales-Indiano, Teresa Arrobas Velilla

    Resumen: Las interferencias analíticas en el laboratorio clínico pueden causar errores en la interpretación de los resultados de diversas magnitudes biológicas por parte del médico peticionario. Las interferencias analíticas más frecuentemente observadas en el laboratorio clínico son la hemólisis, ictericia y lipemia. La lipemia se define como la turbidez de la muestra causada por la acumulación de lipoproteínas, principalmente lipoproteínas de muy baja densidad (VLDL) y quilomicrones. Existen diversos métodos de detección de muestras lipémicas, como por ejemplo, el índice lipémico o la determinación de triglicéridos en muestras de suero o plasma o la Concentración de Hemoglobina Corpuscular Media (CHCM) en muestras de sangre. Las empresas de diagnóstico in vitro son las responsables, según la Directiva Europea 98/79/CE, de realizar el estudio de las sustancias interferentes que pueden afectar a la medición de una magnitud. Existe una necesidad urgente de estandarizar la forma en que se realizan y se reportan los estudios de interferencia por parte de los fabricantes. La interferencia por lipemia puede ser eliminada por diferentes métodos permitiendo la determinación de magnitudes biológicas de manera exacta. El laboratorio clínico debe decidir los protocolos de actuación ante muestras lipémicas dependiendo de la magnitud biológica que se quiere analizar.


  • Open Access

    Association of hyperuricemia and gamma glutamyl transferase as a marker of metabolic risk in alcohol use disorder

    by Anna Hernández-Rubio, Arantza Sanvisens, Ferran Bolao, Clara Pérez-Mañá, Nuria García-Marchena, Carla Fernández-Prendes, Alvaro Muñoz, Roberto Muga

    Excessive alcohol consumption leads to overproduction of urates and renal function plays a critical role in serum uric acid levels. We aimed to assess associations of hyperuricemia in patients with alcohol use disorder (AUD) and comparable Glomerular Filtration Rate (GFR). A total of 686 patients undergoing treatment for AUD between 2013 and 2017 were eligible (77% men); age at admission was 47 years [interquartile range (IQR), 40–53 years], age of onset of alcohol consumption was 16 years [IQR, 16–18 years] and the amount of alcohol consumed was 160 g/day [IQR, 120–240 g/day]. Body Mass Index was 24.7 kg/m2 [IQR, 21.9–28.4 kg/m2], eGFR was 105 mL/min/1.73 m2 [IQR, 95.7–113.0 mL], 9.7% had metabolic syndrome and 23% had advanced liver fibrosis (FIB-4 > 3.25). Prevalence of hyperuricemia was 12.5%. The eGFR-adjusted multivariate analysis showed that relative to patients with GGT ≤ 50, those with GGT between 51 and 300 U/L and those with GGT > 300 U/L were 4.31 (95% CI 1.62–11.46) and 10.3 (95% CI 3.50–29.90) times more likely to have hyperuricemia, respectively. Our data shows that hyperuricemia in the context of AUD is strongly associated with serum GGT levels and suggest an increased cardio-metabolic risk in this population.