Primary operator radiation dose in the cardiac catheter laboratory
- 23 June 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1112) , 20200018
Abstract
Objectives: Radiation from cardiac angiography procedures is harmful to patients and the staff performing them. This study sought to investigate operator radiation dose for a range of procedures and different operators in order to investigate trends and optimise dose. Methods: Real-time dosemeters (RTDs) were worn by operators for angiography procedures for 3 years. Dose–area product (DAP) and RTD were collected. RTD was normalised to DAP (RTD/DAP) to compare radiation dose and radiation protection measures. Comparisons were made across procedure categories and individual operators. Results: In 7626 procedures, median and 75th percentile levels were established for operator dose for 8 procedure categories. There was a significant difference in all operator dose measures and DAP across procedure categories (p<0.001). DAP, RTD, and RTD/DAP were significantly different across 22 individual operators (p<0.001). Conclusion: DAP was significantly different across procedure categories and a higher RTD was seen with higher DAP. RTD/DAP can demonstrate radiation protection effectiveness and identified differences between procedures and individual operators with this measure. Procedures and individuals were identified where further optimisation of radiation protection measures may be beneficial. A reference level for operator dose can be created and audited against on a regular basis. Advances in knowledge: This study demonstrates that operator dose can be easily and routinely measured on a case by case basis to investigate dose trends for different procedures. Normalising the operator dose to DAP demonstrates radiation protection effectiveness for the individual operator which can then be optimised as part of an ongoing audit program.Keywords
This publication has 18 references indexed in Scilit:
- Radiation Exposure of the Operator During Coronary Interventions (from the RADIO Study)The American Journal of Cardiology, 2016
- Effectiveness of Low Rate Fluoroscopy at Reducing Operator and Patient Radiation Dose During Transradial Coronary Angiography and InterventionsJACC: Cardiovascular Interventions, 2014
- A Randomized Comparison of the Transradial and Transfemoral Approaches for Coronary Artery Bypass Graft Angiography and InterventionJACC: Cardiovascular Interventions, 2013
- ICRP Publication 120: Radiological Protection in CardiologyAnnals of the ICRP, 2013
- Patient radiation doses in interventional cardiology in the U.S.: Advisory data sets and possible initial values for U.S. reference levelsMedical Physics, 2012
- Radiation safety program for the cardiac catheterization laboratoryCatheterization and Cardiovascular Interventions, 2011
- OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING CARDIAC CATHETERIZATION PROCEDURESHealth Physics, 2008
- A pilot study exploring the possibility of establishing guidance levels in x-ray directed interventional proceduresMedical Physics, 2008
- Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routesEuropean Heart Journal, 2007
- ACCF/AHA/HRS/SCAI Clinical Competence Statement on Physician Knowledge to Optimize Patient Safety and Image Quality in Fluoroscopically Guided Invasive Cardiovascular ProceduresCirculation, 2005