Nicholas Aroney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nicholas Aroney has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Darren Walters
The Prince Charles Hospital, Queensland, Australia
3 shared publicationsAnthony Putrino
The Prince Charles Hospital, Queensland, Australia
2 shared publicationsBernard Prendergast
Cardiovascular Directorate Guy's and St Thomas' NHS Foundation Trust London UK
2 shared publications- Bernard Prendergast
Heart Vascular and Thoracic Institute, Cleveland Clinic London , London
2 shared publications Christopher J. Allen
Cardiovascular Directorate Guy's and St Thomas' NHS Foundation Trust London UK
2 shared publicationsHarriet Hurrell
Cardiovascular Directorate Guy's and St Thomas' NHS Foundation Trust London UK
2 shared publications
Latest Publications
- 10 June 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (2) , 227-232
Clinical outcomes following single access transfemoral transcatheter aortic valve implantation
Objectives: We describe the first experience using calcification of anatomical landmarks to obviate the need for transcatheter aortic valve implantation (TAVI) alignment aortography and secondary TAVI access.Background: TAVI alignment conventionally involves secondary femoral access for contrast aortography using a second catheter. Secondary femoral access accounts for up to 25% of all vascular complications. Heavily calcified aortic leaflets are often visible fluoroscopically and can act as markers for TAVI alignment.Methods: We considered 100 consecutive patients for transfemoral TAVI. The first group was considered for a conventional dual access technique and the subsequent group was considered for a single access technique. Relevant baseline, and procedural and outcome measures were recorded.Results: Baseline characteristics were comparable between groups. Balloon‐expandable transcatheter heart valves (THV) were used in all cases. THV implantation was successful in 100% of cases with no procedural or in‐hospital mortality. Procedural time and contrast use were lower in the single access group. There were no Valve Academic Research Consortium (VARC)‐2 major vascular complications with the single access technique.Conclusions: This is the first study describing the use of calcification of anatomical landmarks to obviate the need for secondary TAVI access. Notable observations included successful device implantation in all cases, no VARC‐2 major vascular complications, comparable rates of paravalvular leak and permanent pacemaker requirement, shorter procedural times, and lower contrast use. Single access TAVI is a viable alternative technique to minimize vascular access, contrast use, and procedural duration in experienced centers and with selected patients, allowing successful device implantation and low complication rates while further streamlining TAVI workflow.
- 10 June 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (2) , 227-232
Clinical outcomes following single access transfemoral transcatheter aortic valve implantation
Objectives: We describe the first experience using calcification of anatomical landmarks to obviate the need for transcatheter aortic valve implantation (TAVI) alignment aortography and secondary TAVI access.Background: TAVI alignment conventionally involves secondary femoral access for contrast aortography using a second catheter. Secondary femoral access accounts for up to 25% of all vascular complications. Heavily calcified aortic leaflets are often visible fluoroscopically and can act as markers for TAVI alignment.Methods: We considered 100 consecutive patients for transfemoral TAVI. The first group was considered for a conventional dual access technique and the subsequent group was considered for a single access technique. Relevant baseline, and procedural and outcome measures were recorded.Results: Baseline characteristics were comparable between groups. Balloon‐expandable transcatheter heart valves (THV) were used in all cases. THV implantation was successful in 100% of cases with no procedural or in‐hospital mortality. Procedural time and contrast use were lower in the single access group. There were no Valve Academic Research Consortium (VARC)‐2 major vascular complications with the single access technique.Conclusions: This is the first study describing the use of calcification of anatomical landmarks to obviate the need for secondary TAVI access. Notable observations included successful device implantation in all cases, no VARC‐2 major vascular complications, comparable rates of paravalvular leak and permanent pacemaker requirement, shorter procedural times, and lower contrast use. Single access TAVI is a viable alternative technique to minimize vascular access, contrast use, and procedural duration in experienced centers and with selected patients, allowing successful device implantation and low complication rates while further streamlining TAVI workflow.
- Open Access
- 30 June 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3 (10) , 1332-1335
“Gazing Into the Abyss”
- 30 June 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3 (10) , 1332-1335
Open Access“Gazing Into the Abyss”
- Open Access
- 20 April 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (8) , 1789
Neurocognitive Status after Aortic Valve Replacement: Differences between TAVI and Surgery
Over the past decade, indications for transcatheter aortic valve implantation (TAVI) have progressed rapidly—procedural numbers now exceed those of surgical aortic valve replacement (SAVR) in many countries, and TAVI is now a realistic and attractive alternative to SAVR in low-risk patients. Neurocognitive outcomes after TAVI and SAVR remain an issue and sit firmly under the spotlight as TAVI moves into low-risk cohorts. Cognitive decline and stroke carry a significant burden and predict future functional decline, reduced mobility, poor quality of life and increased mortality. Early TAVI trials used varying neurocognitive definitions, and outcomes differed significantly as a result. Recent international consensus statements defining endpoints following TAVI and SAVR have standardised neurological outcomes and facilitate interpretation and comparison between trials. The latest TAVI and SAVR trials have demonstrated more consistent and favourable neurocognitive outcomes for TAVI patients, and cerebral embolic protection devices offer the prospect of further refinement and improvement.
- 20 April 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (8) , 1789
Open AccessNeurocognitive Status after Aortic Valve Replacement: Differences between TAVI and Surgery
Over the past decade, indications for transcatheter aortic valve implantation (TAVI) have progressed rapidly—procedural numbers now exceed those of surgical aortic valve replacement (SAVR) in many countries, and TAVI is now a realistic and attractive alternative to SAVR in low-risk patients. Neurocognitive outcomes after TAVI and SAVR remain an issue and sit firmly under the spotlight as TAVI moves into low-risk cohorts. Cognitive decline and stroke carry a significant burden and predict future functional decline, reduced mobility, poor quality of life and increased mortality. Early TAVI trials used varying neurocognitive definitions, and outcomes differed significantly as a result. Recent international consensus statements defining endpoints following TAVI and SAVR have standardised neurological outcomes and facilitate interpretation and comparison between trials. The latest TAVI and SAVR trials have demonstrated more consistent and favourable neurocognitive outcomes for TAVI patients, and cerebral embolic protection devices offer the prospect of further refinement and improvement.
- 23 June 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1112) , 20200018
Primary operator radiation dose in the cardiac catheter laboratory
Objectives: Radiation from cardiac angiography procedures is harmful to patients and the staff performing them. This study sought to investigate operator radiation dose for a range of procedures and different operators in order to investigate trends and optimise dose. Methods: Real-time dosemeters (RTDs) were worn by operators for angiography procedures for 3 years. Dose–area product (DAP) and RTD were collected. RTD was normalised to DAP (RTD/DAP) to compare radiation dose and radiation protection measures. Comparisons were made across procedure categories and individual operators. Results: In 7626 procedures, median and 75th percentile levels were established for operator dose for 8 procedure categories. There was a significant difference in all operator dose measures and DAP across procedure categories (p<0.001). DAP, RTD, and RTD/DAP were significantly different across 22 individual operators (p<0.001). Conclusion: DAP was significantly different across procedure categories and a higher RTD was seen with higher DAP. RTD/DAP can demonstrate radiation protection effectiveness and identified differences between procedures and individual operators with this measure. Procedures and individuals were identified where further optimisation of radiation protection measures may be beneficial. A reference level for operator dose can be created and audited against on a regular basis. Advances in knowledge: This study demonstrates that operator dose can be easily and routinely measured on a case by case basis to investigate dose trends for different procedures. Normalising the operator dose to DAP demonstrates radiation protection effectiveness for the individual operator which can then be optimised as part of an ongoing audit program.
- 23 June 2020
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1112) , 20200018
Primary operator radiation dose in the cardiac catheter laboratory
Objectives: Radiation from cardiac angiography procedures is harmful to patients and the staff performing them. This study sought to investigate operator radiation dose for a range of procedures and different operators in order to investigate trends and optimise dose. Methods: Real-time dosemeters (RTDs) were worn by operators for angiography procedures for 3 years. Dose–area product (DAP) and RTD were collected. RTD was normalised to DAP (RTD/DAP) to compare radiation dose and radiation protection measures. Comparisons were made across procedure categories and individual operators. Results: In 7626 procedures, median and 75th percentile levels were established for operator dose for 8 procedure categories. There was a significant difference in all operator dose measures and DAP across procedure categories (p<0.001). DAP, RTD, and RTD/DAP were significantly different across 22 individual operators (p<0.001). Conclusion: DAP was significantly different across procedure categories and a higher RTD was seen with higher DAP. RTD/DAP can demonstrate radiation protection effectiveness and identified differences between procedures and individual operators with this measure. Procedures and individuals were identified where further optimisation of radiation protection measures may be beneficial. A reference level for operator dose can be created and audited against on a regular basis. Advances in knowledge: This study demonstrates that operator dose can be easily and routinely measured on a case by case basis to investigate dose trends for different procedures. Normalising the operator dose to DAP demonstrates radiation protection effectiveness for the individual operator which can then be optimised as part of an ongoing audit program.
- Open Access
- 4 May 2019
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 3 (2)
Three-dimensional printed cardiac fistulae: a case series
Background: Three-dimensional (3D) printing of cardiac fistulae allows for immediate understanding of their complex courses and anatomical relations. Models can be used to improve patient understanding, enhance the consenting process, facilitate communication between multidisciplinary staff at heart team meetings, and help plan surgical or percutaneous interventions. Case summary: We report four cases where 3D printed models were used as an adjunct with traditional measures in treating patients with complex cardiac fistulae. Discussion: In our cases, overall patient understanding was improved, staff at heart team meetings were more aware of anatomical anomalies and perioperatively planning saw adjustments made that may have ultimately benefited patient outcome. Our cases highlight the additional benefit that 3D printed models can play when treating patients with complex cardiac fistulae.
- 4 May 2019
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 3 (2)
Open AccessThree-dimensional printed cardiac fistulae: a case series
Background: Three-dimensional (3D) printing of cardiac fistulae allows for immediate understanding of their complex courses and anatomical relations. Models can be used to improve patient understanding, enhance the consenting process, facilitate communication between multidisciplinary staff at heart team meetings, and help plan surgical or percutaneous interventions. Case summary: We report four cases where 3D printed models were used as an adjunct with traditional measures in treating patients with complex cardiac fistulae. Discussion: In our cases, overall patient understanding was improved, staff at heart team meetings were more aware of anatomical anomalies and perioperatively planning saw adjustments made that may have ultimately benefited patient outcome. Our cases highlight the additional benefit that 3D printed models can play when treating patients with complex cardiac fistulae.
- 27 September 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (7) , E478-E480
3D printed cardiac fistula: Guiding percutaneous structural intervention
We present the case of a 21‐year‐old female with a complex right coronary sinus of valsalva to right atrial fistulae. 3D printing of the fistulae and surrounding anatomy was beneficial in assessment of the anatomy and perioperative planning. Successful percutaneous closure was achieved.
- 27 September 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (7) , E478-E480
3D printed cardiac fistula: Guiding percutaneous structural intervention
We present the case of a 21‐year‐old female with a complex right coronary sinus of valsalva to right atrial fistulae. 3D printing of the fistulae and surrounding anatomy was beneficial in assessment of the anatomy and perioperative planning. Successful percutaneous closure was achieved.
- Open Access
- 8 December 2017
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 19 (3) , 268
Three-dimensional printing: to guide management of a right coronary artery to left ventricular fistula
A 26-year-old female presented with 4 weeks of intermittent fever. Physical examination was notable for a diastolic murmur over the left sternal edge. Blood cultures were positive for Streptococcus anginosus. Transthoracic echocardiography demonstrated a mildly dilated left ventricle (LV) with normal function and a markedly dilated right coronary artery (RCA) fistula that enters the basal inferior LV (Panel A) with turbulent Doppler flow across the mitral valve (MV) leaflets. Transoesophageal echocardiography highlighted the severely dilated RCA (Panel C) and revealed a strand-like echodensity associated with the posterior MV leaflet tip, consistent with infective endocarditis (IE). Persistent turbulent flow may have cause scarring and eventual nidus for IE. The patient was treated with intravenous penicillin.
- 8 December 2017
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 19 (3) , 268
Open AccessThree-dimensional printing: to guide management of a right coronary artery to left ventricular fistula
A 26-year-old female presented with 4 weeks of intermittent fever. Physical examination was notable for a diastolic murmur over the left sternal edge. Blood cultures were positive for Streptococcus anginosus. Transthoracic echocardiography demonstrated a mildly dilated left ventricle (LV) with normal function and a markedly dilated right coronary artery (RCA) fistula that enters the basal inferior LV (Panel A) with turbulent Doppler flow across the mitral valve (MV) leaflets. Transoesophageal echocardiography highlighted the severely dilated RCA (Panel C) and revealed a strand-like echodensity associated with the posterior MV leaflet tip, consistent with infective endocarditis (IE). Persistent turbulent flow may have cause scarring and eventual nidus for IE. The patient was treated with intravenous penicillin.
- Open Access
- 8 May 2015
- Published by Wiley in Clinical Case Reports
- Vol. 3 (7) , 527-530
Recurrent undifferentiated shock: Idiopathic Systemic Capillary Leak Syndrome
Key Clinical Message: Idiopathic Systemic Capillary Leak Syndrome is a potentially fatal disorder that is under diagnosed. It commonly presents as recurrent undifferentiated shock with hypotension, hypoalbuminemia and hemoconcentration. There are three distinct phases that define the syndrome; Prodromal, Extravasation and Recovery.
- 8 May 2015
- Published by Wiley in Clinical Case Reports
- Vol. 3 (7) , 527-530
Open AccessRecurrent undifferentiated shock: Idiopathic Systemic Capillary Leak Syndrome
Key Clinical Message: Idiopathic Systemic Capillary Leak Syndrome is a potentially fatal disorder that is under diagnosed. It commonly presents as recurrent undifferentiated shock with hypotension, hypoalbuminemia and hemoconcentration. There are three distinct phases that define the syndrome; Prodromal, Extravasation and Recovery.