Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease
Open Access
- 14 February 2020
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (2) , e0228992
Abstract
Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11–1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46–0.56 D) and the AK (0.54 D, 95% CI 0.48–0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.Keywords
This publication has 26 references indexed in Scilit:
- Corneal Collagen Cross-linking with Riboflavin and Ultraviolet A Irradiation for KeratoconusOphthalmology, 2013
- Prevalence and Associations of Steep Cornea/Keratoconus in Greater Beijing. The Beijing Eye StudyPLOS ONE, 2012
- Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconusJournal of Cataract & Refractive Surgery, 2012
- Collagen crosslinking with riboflavin and ultraviolet-A light in keratoconus: Long-term resultsJournal of Cataract & Refractive Surgery, 2008
- Comparison of two dependent within subject coefficients of variation to evaluate the reproducibility of measurement devicesBMC Medical Research Methodology, 2008
- Changes in the Quality-of-Life of People with KeratoconusAmerican Journal of Ophthalmology, 2008
- Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variablesUltrasound in Obstetrics & Gynecology, 2008
- Statistics Notes: Measurement error proportional to the meanBMJ, 1996
- Statistics notes: Measurement errorBMJ, 1996
- Forming inferences about some intraclass correlation coefficients.Psychological Methods, 1996