Anders Bergström
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anders Bergström has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Anders Ivarsen
Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationAnna Cardiakides Myers
Department of Clinical Sciences, Faculty of Medicine, Lund University, Lund, Sweden
1 shared publication- Boel Bengtsson
Department of Clinical Sciences in Malmö, Ophthalmology Lund University Malmö Sweden
1 shared publication - Dragana Škiljić
Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
1 shared publication - Ingemar Gustafsson
Department of Clinical Sciences, Ophthalmology, Lund University, Skåne University Hospital, Lund, Sweden
1 shared publication Jesper Hjortdal
Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark
1 shared publication
Latest Publications
- Open Access
- 3 July 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 1897-1910
Four-Year Outcome of XEN 45 Gel Stent Implantation in a Swedish Population
Purpose: To report the long-time success rate of XEN 45 gel stent implantation in a Scandinavian population. Patients and Methods: This was a retrospective single-center analysis of all patients undergoing XEN 45 stent surgery between December 2015 and May 2017. The main outcome was success rate according to several definitions of success. Subgroup analysis was performed. Secondary outcomes were change in intraocular pressure (IOP) and number of IOP-lowering agents. Need for secondary glaucoma surgery, needling rate and complications were recorded. Results: A total of 103 eyes could be evaluated after four years. Mean age was 70.6 years. Primary open-angle glaucoma (POAG) accounted for 46.6% and exfoliative glaucoma (PEXG) for 39.8%. Mean IOP dropped from 24.0 to 15.9 mmHg (p< 0.001) and IOP-lowering agents from 3.5 to 1.5 (p< 0.001). The success rate with individual target pressures after four years was 43.7%. Secondary glaucoma surgery was performed in 45 (43.7%) of cases. Combined cases (n=12) were not statistically different to stand-alone procedures (p=0.28). No difference between PEXG and POAG could be detected (p=0.44). During the learning curve, stent misplacement was common and resulted in worse outcome for less experienced surgeons. Conclusion: The overall success rate of XEN 45 gel stent surgery in the present cohort is relatively low in a long-time follow-up under the given circumstances if all initial patients are included to follow-up. The influence of the surgeon’s learning curve is obvious, and improvement in success can be expected when used by experienced and high-volume surgeons. No significant differences were found in PEXG compared to POAG or in XEN surgery combined with cataract surgery compared to stand-alone.
- 3 July 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 1897-1910
Open AccessFour-Year Outcome of XEN 45 Gel Stent Implantation in a Swedish Population
Purpose: To report the long-time success rate of XEN 45 gel stent implantation in a Scandinavian population. Patients and Methods: This was a retrospective single-center analysis of all patients undergoing XEN 45 stent surgery between December 2015 and May 2017. The main outcome was success rate according to several definitions of success. Subgroup analysis was performed. Secondary outcomes were change in intraocular pressure (IOP) and number of IOP-lowering agents. Need for secondary glaucoma surgery, needling rate and complications were recorded. Results: A total of 103 eyes could be evaluated after four years. Mean age was 70.6 years. Primary open-angle glaucoma (POAG) accounted for 46.6% and exfoliative glaucoma (PEXG) for 39.8%. Mean IOP dropped from 24.0 to 15.9 mmHg (p< 0.001) and IOP-lowering agents from 3.5 to 1.5 (p< 0.001). The success rate with individual target pressures after four years was 43.7%. Secondary glaucoma surgery was performed in 45 (43.7%) of cases. Combined cases (n=12) were not statistically different to stand-alone procedures (p=0.28). No difference between PEXG and POAG could be detected (p=0.44). During the learning curve, stent misplacement was common and resulted in worse outcome for less experienced surgeons. Conclusion: The overall success rate of XEN 45 gel stent surgery in the present cohort is relatively low in a long-time follow-up under the given circumstances if all initial patients are included to follow-up. The influence of the surgeon’s learning curve is obvious, and improvement in success can be expected when used by experienced and high-volume surgeons. No significant differences were found in PEXG compared to POAG or in XEN surgery combined with cataract surgery compared to stand-alone.
- Open Access
- 7 May 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (6) , E790-E791
A first report on the short‐term effects of two different approaches to hydroexpand the conjunctiva in ab interno gelatin microstent surgery
- 7 May 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (6) , E790-E791
Open AccessA first report on the short‐term effects of two different approaches to hydroexpand the conjunctiva in ab interno gelatin microstent surgery
- Open Access
- 14 February 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (2) , e0228992
Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease
Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11–1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46–0.56 D) and the AK (0.54 D, 95% CI 0.48–0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.
- 14 February 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (2) , e0228992
Open AccessAssociation between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease
Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11–1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46–0.56 D) and the AK (0.54 D, 95% CI 0.48–0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.