Comparison of the use of single capillaries and coupled capillaries based on micellar electrokinetic chromatography (MEKC) and sweeping‐MEKC modes
Authors:
- 15 February 2005
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 26 (4-5) , 962-969
Abstract
The use of single capillaries (25 and 50 μm inner diameter (ID)) and coupled capillaries of different diameters (100–50 and 75–25 μm ID) based on micellar electrokinetic chromatography (MEKC) and sweeping‐MEKC modes is compared and reported. Naphthalene‐2,3‐dicarboxaldehyde (NDA)‐derivatized dopamine was selected as the model compound by examining the fluorescence intensity when a violet (410 ± 7 nm, ˜2 mW) light‐emitting‐diode (LED) was used as the light source. When a single capillary (50 μm ID) was used, the detection limit for NDA‐derivatized dopamine was determined to be 2.0 × 10−7 M (Signal‐to‐nose ratio S/N = 3) based on the MEKC mode. This was improved to 4.0 × 10−9 M when the sweeping‐MEKC mode was applied. In addition, this can be further improved to 1.0 × 10−9 M and 5.6 × 10−10 M when 100–50 and 75–25 μm ID coupled capillaries are used. The use of the coupled capillary is also helpful for improving the separation efficiency. Based on the sweeping‐MEKC mode, the number of theoretical plates (N) for the detected peaks were determined to be 6.3 ± 2.7 × 105 by means of a single capillary (50 μm ID). This can be improved to 9.4 ± 3.6 × 105 and 9.4 ± 0.9 × 106 when the 100–50 and 75–25 μm ID coupled capillaries were applied.Keywords
This publication has 23 references indexed in Scilit:
- Use of coupled open-tubular capillaries for in-line ion-exchange preconcentration of anions by capillary electrochromatography with elution by a transient isotachophoretic gradientJournal of Chromatography A, 2004
- Isotachophoretic separation of alkylsulfonates and determination of methanesulfonic acid as main component and as trace component in pharmaceutical drug substancesJournal of Chromatography A, 2004
- Determination of free sulfite in wine by zone electrophoresis with isotachophoresis sample pretreatment on a column-coupling chipJournal of Chromatography A, 2004
- On-Line Focusing of Flavin Derivatives Using Dynamic pH Junction-Sweeping Capillary Electrophoresis with Laser-Induced Fluorescence DetectionAnalytical Chemistry, 2002
- Counterflow Isotachophoresis−Capillary Zone Electrophoresis on Directly Coupled Columns of Different DiametersAnalytical Chemistry, 1998
- Improvement in the method of sample stacking for gravity injection in capillary zone electrophoresisAnalytical Biochemistry, 1992
- On-line coupling of capillary isotachophoresis with capillary zone electrophoresisJournal of Chromatography A, 1990
- Large sample volume preseparation for trace analysis in isotachophoresisJournal of Chromatography A, 1985
- Zone electrophoresis in open-tubular glass capillariesAnalytical Chemistry, 1981
- Determination of substances at low concentrations in complex mixtures by isotachophoresis with column couplingJournal of Chromatography A, 1979