Evaluation of intracoronary stenting by intravascular optical coherence tomography
Authors:
Open Access
Abstract
Background: Conventional contrast cineangiography and intravascular ultrasound (IVUS) provide a limited definition of vessel microstructure and are unable to evaluate dissection, tissue prolapse, and stent apposition on a size scale less than 100 μm. Objective: To evaluate the use of intravascular optical coherence tomography (OCT) to assess the coronary arteries in patients undergoing coronary stenting. Methods: OCT was employed in patients having percutaneous coronary interventions. Images were obtained before initial balloon dilatation and following stent deployment, and were evaluated for vessel dissection, tissue prolapse, stent apposition, and stent asymmetry. IVUS images were obtained before OCT, using an automatic pull back device. Results: 42 stents were imaged in 39 patients without complications. Dissection, prolapse, and incomplete stent apposition were observed more often with OCT than with IVUS. Vessel dissection was identified in eight stents by OCT and two by IVUS. Tissue prolapse was identified in 29 stents by OCT and 12 by IVUS; the extent of the prolapse (mean (SD)) was 242 (156) μm by OCT and 400 (100) μm by IVUS. Incomplete stent apposition was observed in seven stents by OCT and three by IVUS. Irregular strut separation was identified in 18 stents by both OCT and IVUS. Conclusions: Intracoronary OCT for monitoring stent deployment is feasible and provides superior contrast and resolution of arterial pathology than IVUS.Keywords
This publication has 25 references indexed in Scilit:
- Visualization of Tissue Prolapse Between Coronary Stent Struts by Optical Coherence TomographyCirculation, 2001
- Randomized Comparison of Coronary Stent Implantation Under Ultrasound or Angiographic Guidance to Reduce Stent Restenosis (OPTICUS Study)Circulation, 2001
- Novel Drug-Delivery StentCirculation, 2001
- Porcine coronary imaging in vivo by optical coherence tomographyActa Cardiologica, 2000
- Mechanism of Lumen Enlargement During Intracoronary Stent ImplantationCirculation, 2000
- Coronary stent symmetry and vascular injury determine experimental restenosisHeart, 2000
- Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies—with and without intravascular ultrasound guidanceJACC, 1998
- Patterns and Mechanisms of In-Stent RestenosisCirculation, 1996
- Intracoronary ultrasound observations during stent implantation.Circulation, 1994
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992