Paradigm Shift: Major Role of Ion-Pairing-Dependent Size Exclusion Effects in Bottom-Up Proteomics Reversed-Phase Peptide Separations
- 29 May 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (23) , 9721-9728
Abstract
Can reversed-phase peptide retention be the same for C8 and C18 columns? or increase for otherwise identical columns with a smaller surface area? Can replacing trifluoroacetic acid (TFA) with formic acid (FA) improve the peak shape? According to our common understanding of peptide chromatography, absolutely not. Surprisingly, a thorough comparison of the peptide separation selectivity of 100 and 120 angstrom fully porous C18 sorbents to maximize the performance of our in-house proteomics LC-MS/MS setup revealed an unexpectedly higher peptide retentivity for a wider pore packing material, despite it having a smaller surface area. Concurrently, the observed increase in peptide retention-which drives variation in separation selectivity between 100 and 120 angstrom pore size materials-was more pronounced for smaller peptides. These findings contradict the central dogmas that underlie the development of all peptide RP-HPLC applications: (i) a larger surface area leads to higher retention and (ii) increasing the pore size should benefit the retention of larger analytes. Based on our intriguing findings, we compared reversed-phase high-performance liquid chromatography peptide retention for a total of 20 columns with pore sizes between 60 and 300 angstrom using FA- and TFA-based eluents. Our results unequivocally attest that the larger size of ion pairs in FA- vs TFA-based eluents leads to the observed impact on selectivity and peptide retention. For FA, peptide retention peaks at 200 angstrom pore size, compared to between 120 and 200 angstrom for TFA. However, the decrease in retention for narrow-pore particles is more profound in FA. Our findings suggest that common assumptions about analyte size and accessible surface area should be revisited for ion-pair RP separation of small peptides, typical for proteomic applications that are predominantly applying FA eluents. Hybrid silica-based materials with pore sizes of 130-200 angstrom should be specifically targeted for bottom-up proteomic applications to obtain both superior peak shape and peptide retentivity. This challenging task of attaining the best RPLC column for proteomics calls for closer collaboration between LC column manufacturers and proteomic LC specialists.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2022-05015)
- H. E. Seller Research Chair in Internal Medicine, University of Manitoba
This publication has 28 references indexed in Scilit:
- How changing the particle structure can speed up protein mass transfer kinetics in liquid chromatographyJournal of Chromatography A, 2012
- HPLC Analysis and Purification of Peptides2007
- Effect of anionic ion-pairing reagent hydrophobicity on selectivity of peptide separations by reversed-phase liquid chromatographyJournal of Chromatography A, 2005
- Proteomic LC–MS systems using nanoscale liquid chromatography with tandem mass spectrometryJournal of Chromatography A, 2005
- Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatographyJournal of Chromatography A, 2004
- Effect of buffer on peak shape of peptides in reversed-phase high performance liquid chromatographyJournal of Chromatography A, 2004
- Ion chromatographyAnalytical and Bioanalytical Chemistry, 2004
- Prediction of peptide retention times in reversed-phase high-performance liquid chromatography I. Determination of retention coefficients of amino acid residues of model synthetic peptidesJournal of Chromatography A, 1986
- The importance of silica type for reverse-phase protein separationsAnalytical Biochemistry, 1982
- High-performance liquid chromatography of proteinsAnalytical Biochemistry, 1980