A 36 μW 1.1 mm2 Reconfigurable Analog Front-End for Cardiovascular and Respiratory Signals Recording
Open Access
- 6 April 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 774-783
Abstract
This paper presents a 1.2 V 36 μW reconfigurable analog front-end (R-AFE) as a general-purpose low-cost IC for multiple-mode biomedical signals acquisition. The R-AFE efficiently reuses a reconfigurable preamplifier, a current generator (CG), and a mixed signal processing unit, having an area of 1.1 mm2 per R-AFE while supporting five acquisition modes to record different forms of cardiovascular and respiratory signals. The R-AFE can interface with voltage-, current-, impedance-, and light-sensors and hence can measure electrocardiography (ECG), bio-impedance (BioZ), photoplethysmogram (PPG), galvanic skin response (GSR), and general-purpose analog signals. Thanks to the chopper preamplifier and the low-noise CG utilizing dynamic element matching, the R-AFE mitigates 1/f noise from both the preamplifier and the CG for improved measurement sensitivity. The IC achieves competitive performance compared to the state-of-the-art dedicated readout ICs of ECG, BioZ, GSR, and PPG, but with approximately 1.4×-5.3× smaller chip area per channel.Keywords
This publication has 13 references indexed in Scilit:
- Reconfigurable Multiparameter Biosignal Acquisition SoC for Low Power Wearable PlatformSensors, 2016
- A 13.2 b Optical Proximity Sensor System With 130 klx Ambient Light Rejection Capable of Heart Rate and Blood Oximetry MonitoringIEEE Journal of Solid-State Circuits, 2016
- 28.4 A battery-powered efficient multi-sensor acquisition system with simultaneous ECG, BIO-Z, GSR, and PPG2016
- Ultralow-Power Bioimpedance IC With Intermediate Frequency Shifting ChopperIEEE Transactions on Circuits and Systems II: Express Briefs, 2015
- A low power configurable bio-impedance spectroscopy (BIS) ASIC with simultaneous ECG and respiration recording functionality2015
- A 4.9 mΩ-Sensitivity Mobile Electrical Impedance Tomography IC for Early Breast-Cancer Detection SystemIEEE Journal of Solid-State Circuits, 2014
- A Self-Powered CMOS Reconfigurable Multi-Sensor SoC for Biomedical ApplicationsIEEE Journal of Solid-State Circuits, 2014
- A multi-frequency bioimpedance measurement ASIC for electrical impedance tomography2011
- Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilizationProceedings of the IEEE, 1996
- A compact power-efficient 3 V CMOS rail-to-rail input/output operational amplifier for VLSI cell librariesIEEE Journal of Solid-State Circuits, 1994