Hyunsoo Ha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hyunsoo Ha has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Jae-Yoon Sim
Pohang University of Science and Technology, Pohang, Korea
8 shared publications- Nick Van Helleputte
IMEC
8 shared publications Chris Van Hoof
ImecNetherlands, Eindhoven, AE, The Netherlands
5 shared publicationsHong-June Park
Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Korea
5 shared publications- Jiawei Xu
Fudan University
5 shared publications - Mario Konijnenburg
IMEC, Eindhoven, The Netherlands
5 shared publications
Latest Publications
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1506-1517
A 769 μW Battery-Powered Single-Chip SoC With BLE for Multi-Modal Vital Sign Monitoring Health Patches
An all-in-one battery powered low-power SoC for measuring multiple vital signs with wearables is proposed. All functionality needed in a typical wearable use case scenario, including dedicated readouts, power management circuitry, digital signal processing and wireless communication (BLE) is integrated in a single die. This high level of integration allows an unprecedented level of miniaturization leading to smaller component count which reduces cost and improves comfort and signal integrity. The SoC includes an ECG, Bio-Impedance and a fully differential PPG readout and can interface with external sensors (like an IMU). In a typical application scenario where all sensor readouts are enabled and key features (like heart rate) are calculated on the chip and streamed over the radio, the SoC consumes only 769μW from the regulated 1.2V supply.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1506-1517
A 769 μW Battery-Powered Single-Chip SoC With BLE for Multi-Modal Vital Sign Monitoring Health Patches
An all-in-one battery powered low-power SoC for measuring multiple vital signs with wearables is proposed. All functionality needed in a typical wearable use case scenario, including dedicated readouts, power management circuitry, digital signal processing and wireless communication (BLE) is integrated in a single die. This high level of integration allows an unprecedented level of miniaturization leading to smaller component count which reduces cost and improves comfort and signal integrity. The SoC includes an ECG, Bio-Impedance and a fully differential PPG readout and can interface with external sensors (like an IMU). In a typical application scenario where all sensor readouts are enabled and key features (like heart rate) are calculated on the chip and streamed over the radio, the SoC consumes only 769μW from the regulated 1.2V supply.
- 23 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (11) , 2969-2979
A Bio-Impedance Readout IC With Digital-Assisted Baseline Cancellation for Two-Electrode Measurement
The measurement of the tissue or bio-impedance (BIOZ) is a safe and power-efficient sensing modality that can be adopted for the acquisition of vital signals, such as respiration and heartbeat. A BIOZ readout IC with a wide-input impedance range is proposed. The IC supports vital signal acquisition through a two-electrode setup which requires a larger dynamic range than the conventional four-electrode setup. A digital-assisted baseline impedance cancellation method is implemented to measure small tissue impedance variations originating from respiration and heartbeat in the presence of larger baseline impedances. The proposed technique also mitigates the input-dependent noise behavior of the readout front-end by minimizing the effective input signal to the instrumentation amplifier (IA). The baseline cancellation loop further improves the noise performance by cancelling the reference current noise from the current generator (CG). Hence, one single solution--baseline cancellation--resolves two issues facilitating two-electrode BIOZ setups achieving similar impedance resolution performance compared with more four-electrode setups. The IC, fabricated in a 55-nm CMOS, can measure tissue impedances over a frequency range from 1 kHz to 1 MHz and can achieve a maximum input range of 24 kΩ (at the impedance measurement frequency) and a best-case resolution of 2 mΩ RMS (for a 100-Ω input). This increases to 14.0 mΩRMS for a 2-kΩ input impedance. The ASIC consumes 18.9-34.9 and 31.4-154.7 μW for the readout front-end and the CG, respectively. The power depends on the injected current amplitudes. A successful demonstration on the human body through a two-electrode (gel and dry) setup confirms the effectivity of the proposed work in a real use case.
- 23 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 54 (11) , 2969-2979
A Bio-Impedance Readout IC With Digital-Assisted Baseline Cancellation for Two-Electrode Measurement
The measurement of the tissue or bio-impedance (BIOZ) is a safe and power-efficient sensing modality that can be adopted for the acquisition of vital signals, such as respiration and heartbeat. A BIOZ readout IC with a wide-input impedance range is proposed. The IC supports vital signal acquisition through a two-electrode setup which requires a larger dynamic range than the conventional four-electrode setup. A digital-assisted baseline impedance cancellation method is implemented to measure small tissue impedance variations originating from respiration and heartbeat in the presence of larger baseline impedances. The proposed technique also mitigates the input-dependent noise behavior of the readout front-end by minimizing the effective input signal to the instrumentation amplifier (IA). The baseline cancellation loop further improves the noise performance by cancelling the reference current noise from the current generator (CG). Hence, one single solution--baseline cancellation--resolves two issues facilitating two-electrode BIOZ setups achieving similar impedance resolution performance compared with more four-electrode setups. The IC, fabricated in a 55-nm CMOS, can measure tissue impedances over a frequency range from 1 kHz to 1 MHz and can achieve a maximum input range of 24 kΩ (at the impedance measurement frequency) and a best-case resolution of 2 mΩ RMS (for a 100-Ω input). This increases to 14.0 mΩRMS for a 2-kΩ input impedance. The ASIC consumes 18.9-34.9 and 31.4-154.7 μW for the readout front-end and the CG, respectively. The power depends on the injected current amplitudes. A successful demonstration on the human body through a two-electrode (gel and dry) setup confirms the effectivity of the proposed work in a real use case.
- 26 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1267-1277
A 665 μW Silicon Photomultiplier-Based NIRS/EEG/EIT Monitoring ASIC for Wearable Functional Brain Imaging
This paper presents a sub-mW ASIC for multimodal brain monitoring. The ASIC is co-integrated with electrode(s) and optodes (i.e. optical source and detector) as an active sensor to measure electroencephalography (EEG), bio-impedance (BioZ), and near-infrared spectroscopy (NIRS) on scalp. The target is to build a wearable EEG-NIRS headset for low-cost functional brain imaging. The proposed NIRS readout utilizing the near-infrared light can be used to measure the pulse oximetry and blood oxygen saturation (SpO2). While traditional photodiodes are supported, the readout also allows the use of silicon photomultipliers (SiPMs) as optical detectors. The SiPM improves optical sensitivity while significantly reducing the average power of two LEDs to 150 μW. On circuit level, a SAR-based calibration compensates maximum 40 μA current from ambient light, while digital DC-servo loops (D-DSLs) reduces the baseline static SiPM current up to 400 μA, leading to an overall dynamic range of 87 dB. The EEG readout exhibits 720 Mμ input impedance at 50 Hz. The BioZ readout has 3 mΩ/(Hz) impedance sensitivity by employing dynamic circuit techniques. When EEG, BioZ and NIRS are enabled at the same time, one ASIC consumes 665 μW including the power of LEDs.
- 26 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1267-1277
A 665 μW Silicon Photomultiplier-Based NIRS/EEG/EIT Monitoring ASIC for Wearable Functional Brain Imaging
This paper presents a sub-mW ASIC for multimodal brain monitoring. The ASIC is co-integrated with electrode(s) and optodes (i.e. optical source and detector) as an active sensor to measure electroencephalography (EEG), bio-impedance (BioZ), and near-infrared spectroscopy (NIRS) on scalp. The target is to build a wearable EEG-NIRS headset for low-cost functional brain imaging. The proposed NIRS readout utilizing the near-infrared light can be used to measure the pulse oximetry and blood oxygen saturation (SpO2). While traditional photodiodes are supported, the readout also allows the use of silicon photomultipliers (SiPMs) as optical detectors. The SiPM improves optical sensitivity while significantly reducing the average power of two LEDs to 150 μW. On circuit level, a SAR-based calibration compensates maximum 40 μA current from ambient light, while digital DC-servo loops (D-DSLs) reduces the baseline static SiPM current up to 400 μA, leading to an overall dynamic range of 87 dB. The EEG readout exhibits 720 Mμ input impedance at 50 Hz. The BioZ readout has 3 mΩ/(Hz) impedance sensitivity by employing dynamic circuit techniques. When EEG, BioZ and NIRS are enabled at the same time, one ASIC consumes 665 μW including the power of LEDs.
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 1 (4) , 90-93
Measurement and Analysis of Input-Signal Dependent Flicker Noise Modulation in Chopper Stabilized Instrumentation Amplifier
This letter presents measurement results and an analysis of an input-signal dependent flicker noise modulation in chopper stabilized current balancing instrumentation amplifier. Although the chopping is well known and often used for its effectiveness in flicker noise mitigation, measurement results show an increased effect of the 1/f noise proportional to input signal amplitude. This effect is often ignored in most publications and will also not be apparent in traditional noise measurements (due to the lack of input signal when doing noise measurements). The unexpected operation was confirmed by a Spectre simulation and the main cause can be attributed to a flicker noise modulation by input signals of large amplitude. Because of the signal-dependency of the effect, flicker noise remains (and can be significant) even when chopping is applied.
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 1 (4) , 90-93
Measurement and Analysis of Input-Signal Dependent Flicker Noise Modulation in Chopper Stabilized Instrumentation Amplifier
This letter presents measurement results and an analysis of an input-signal dependent flicker noise modulation in chopper stabilized current balancing instrumentation amplifier. Although the chopping is well known and often used for its effectiveness in flicker noise mitigation, measurement results show an increased effect of the 1/f noise proportional to input signal amplitude. This effect is often ignored in most publications and will also not be apparent in traditional noise measurements (due to the lack of input signal when doing noise measurements). The unexpected operation was confirmed by a Spectre simulation and the main cause can be attributed to a flicker noise modulation by input signals of large amplitude. Because of the signal-dependency of the effect, flicker noise remains (and can be significant) even when chopping is applied.
- Open Access
- 6 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 774-783
A 36 μW 1.1 mm2 Reconfigurable Analog Front-End for Cardiovascular and Respiratory Signals Recording
This paper presents a 1.2 V 36 μW reconfigurable analog front-end (R-AFE) as a general-purpose low-cost IC for multiple-mode biomedical signals acquisition. The R-AFE efficiently reuses a reconfigurable preamplifier, a current generator (CG), and a mixed signal processing unit, having an area of 1.1 mm2 per R-AFE while supporting five acquisition modes to record different forms of cardiovascular and respiratory signals. The R-AFE can interface with voltage-, current-, impedance-, and light-sensors and hence can measure electrocardiography (ECG), bio-impedance (BioZ), photoplethysmogram (PPG), galvanic skin response (GSR), and general-purpose analog signals. Thanks to the chopper preamplifier and the low-noise CG utilizing dynamic element matching, the R-AFE mitigates 1/f noise from both the preamplifier and the CG for improved measurement sensitivity. The IC achieves competitive performance compared to the state-of-the-art dedicated readout ICs of ECG, BioZ, GSR, and PPG, but with approximately 1.4×-5.3× smaller chip area per channel.
- 6 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 774-783
Open AccessA 36 μW 1.1 mm2 Reconfigurable Analog Front-End for Cardiovascular and Respiratory Signals Recording
This paper presents a 1.2 V 36 μW reconfigurable analog front-end (R-AFE) as a general-purpose low-cost IC for multiple-mode biomedical signals acquisition. The R-AFE efficiently reuses a reconfigurable preamplifier, a current generator (CG), and a mixed signal processing unit, having an area of 1.1 mm2 per R-AFE while supporting five acquisition modes to record different forms of cardiovascular and respiratory signals. The R-AFE can interface with voltage-, current-, impedance-, and light-sensors and hence can measure electrocardiography (ECG), bio-impedance (BioZ), photoplethysmogram (PPG), galvanic skin response (GSR), and general-purpose analog signals. Thanks to the chopper preamplifier and the low-noise CG utilizing dynamic element matching, the R-AFE mitigates 1/f noise from both the preamplifier and the CG for improved measurement sensitivity. The IC achieves competitive performance compared to the state-of-the-art dedicated readout ICs of ECG, BioZ, GSR, and PPG, but with approximately 1.4×-5.3× smaller chip area per channel.
- 1 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 294-296
A 665μW silicon photomultiplier-based NIRS/EEG/EIT monitoring asic for wearable functional brain imaging
Functional brain imaging is considered a powerful and practical solution for understanding the brain and neurological diseases. While EEG is an established method for non-invasive electrical activity, electrical-impedance tomography (EIT) and near-infrared spectroscopy (NIRS) can additionally measure impedance changes and hemodynamic processes. To facilitate long-term multi-channel brain imaging in a wearable form factor without cabling overhead, there is a need for low-power local amplifiers [1] to support all these modalities. The main principle of optical hemodynamic measurements is to send light pulses into the tissue and measure the reflected light, which is modulated by the oxygen levels in the blood (Fig. 17.8.1). State-of-the-art NIRS ICs typically consume a few mW, primarily for the LEDs to meet the required light sensitivity at the photodiodes (PDs). Silicon photomultipliers (SiPMs) are promising alternatives because they have excellent low-light detection capabilities, speed of response and higher detection efficiency in both visible and near infrared range [2]. Hence, SiPMs allow deeper brain sensing depth and the possibility to sample consistent cerebral regions with larger inter-optode distance. This benefit would significantly reduce the number of NIRS channels and the associated power for a wearable NIRS device. Although SiPMs require a higher bias voltage (~30V) than PDs, they achieve similar NIRS responses with a few hundred times less LED current. This results in a low-power NIRS ASIC and an overall power-efficient system. Existing optical sensing ICs are not suitable for a SiPM because of its large and variable output current. Trimming-based calibration methods [3] suffer from drift over time. Auto-zeroing by swapping an integrator capacitor [4][5] compensates ambient light at the cost of the integrator's headroom. Apart from ambient light, the dynamic range (DR) of the amplifier is also limited by a large NIRS signal, leading to a power-hungry readout.
- 1 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 294-296
A 665μW silicon photomultiplier-based NIRS/EEG/EIT monitoring asic for wearable functional brain imaging
Functional brain imaging is considered a powerful and practical solution for understanding the brain and neurological diseases. While EEG is an established method for non-invasive electrical activity, electrical-impedance tomography (EIT) and near-infrared spectroscopy (NIRS) can additionally measure impedance changes and hemodynamic processes. To facilitate long-term multi-channel brain imaging in a wearable form factor without cabling overhead, there is a need for low-power local amplifiers [1] to support all these modalities. The main principle of optical hemodynamic measurements is to send light pulses into the tissue and measure the reflected light, which is modulated by the oxygen levels in the blood (Fig. 17.8.1). State-of-the-art NIRS ICs typically consume a few mW, primarily for the LEDs to meet the required light sensitivity at the photodiodes (PDs). Silicon photomultipliers (SiPMs) are promising alternatives because they have excellent low-light detection capabilities, speed of response and higher detection efficiency in both visible and near infrared range [2]. Hence, SiPMs allow deeper brain sensing depth and the possibility to sample consistent cerebral regions with larger inter-optode distance. This benefit would significantly reduce the number of NIRS channels and the associated power for a wearable NIRS device. Although SiPMs require a higher bias voltage (~30V) than PDs, they achieve similar NIRS responses with a few hundred times less LED current. This results in a low-power NIRS ASIC and an overall power-efficient system. Existing optical sensing ICs are not suitable for a SiPM because of its large and variable output current. Trimming-based calibration methods [3] suffer from drift over time. Auto-zeroing by swapping an integrator capacitor [4][5] compensates ambient light at the cost of the integrator's headroom. Apart from ambient light, the dynamic range (DR) of the amplifier is also limited by a large NIRS signal, leading to a power-hungry readout.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. C170-C171
A 36μW reconfigurable analog front-end IC for multimodal vital signs monitoring
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. C170-C171
A 36μW reconfigurable analog front-end IC for multimodal vital signs monitoring
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An ultra-low-power biomedical chip for injectable pressure monitor
Implantable pressure monitors enable diagnosis and track patient health or disease progression in different organs such as the brain, eye, heart, and bladder. Miniaturization of the implantable sensors helps reduce patient pain and recovery time, decrease foreign body rejection, and allow the device to be placed in limited spaces. This paper explores a miniaturized pressure monitor which can even be injected through a syringe. Required specifications are investigated to develop the small pressure monitor. Also, low-power circuit techniques to meet extremely small power budget are discussed for a capacitive-to-digital converter, an energy harvester, and digital circuits.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An ultra-low-power biomedical chip for injectable pressure monitor
Implantable pressure monitors enable diagnosis and track patient health or disease progression in different organs such as the brain, eye, heart, and bladder. Miniaturization of the implantable sensors helps reduce patient pain and recovery time, decrease foreign body rejection, and allow the device to be placed in limited spaces. This paper explores a miniaturized pressure monitor which can even be injected through a syringe. Required specifications are investigated to develop the small pressure monitor. Also, low-power circuit techniques to meet extremely small power budget are discussed for a capacitive-to-digital converter, an energy harvester, and digital circuits.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 08865930,p. 1-7
Circuit techniques for miniaturized biomedical sensors
Miniaturized biomedical sensors promise improved quality of medical diagnosis and treatment. However, the realization of such implantable devices faces challenges due to limited battery capacity and energy sources. This paper describes new circuit techniques for miniaturized biomedical sensors, with particular emphasis on bio-signals sensing front end, power management, and communication.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 08865930,p. 1-7
Circuit techniques for miniaturized biomedical sensors
Miniaturized biomedical sensors promise improved quality of medical diagnosis and treatment. However, the realization of such implantable devices faces challenges due to limited battery capacity and energy sources. This paper describes new circuit techniques for miniaturized biomedical sensors, with particular emphasis on bio-signals sensing front end, power management, and communication.