Physician-Modified Reversed Iliac Branch Device to Prevent Spinal Cord Ischemia in an Urgent Branched Endovascular Aortic Repair
- 26 July 2024
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (1) , 121-127
Abstract
Purpose: Repair of pararenal aneurysms poses a challenge, especially in an urgent setting. Despite the minimally invasive nature of the fenestrated/branched endovascular aortic repair, the technique may require extensive coverage of the aorta, increasing the risk of spinal cord ischemia. Technique: A 68-year-old man was admitted with a rapid enlargement of an asymptomatic juxtarenal aortic aneurysm. A minimally invasive treatment with an off-the-shelf branched endovascular graft was planned. Before completing the aneurysm exclusion, an angiography highlighted a large lumbar artery, potentially significant for the perfusion of the spinal cord collateral network. Owing to this finding and an unsuccessful placement of the cerebrospinal fluid drainage, the procedure was staged and completed 5 days later using a physician-modified iliac branch device (IBD) for the segmental artery. The device was shortened and reversely loaded to obtain a cranially-oriented branch. A balloon-expandable covered stent was used to connect the retrograde branch (8 mm) to the lumbar artery (4 mm). Pre-discharge computed tomography (CT)-angiography confirmed the vessel patency. No neurological symptoms occurred. Conclusion: The use of a reversely-loaded IBD for segmental artery preservation appears feasible and safe. Clinical Impact: Intraoperative modification of an iliac branch device during an urgent branched endovascular aortic repair enabled preservation of a potentially critical segmental artery, thus reducing the risk of spinal cord ischemia. This adaptive interventional technique may also offer a strategy for preserving other anatomically significant vessels, such as accessory renal arteries, during complex aortic reconstructions in urgent settings.Keywords
This publication has 24 references indexed in Scilit:
- Feasibility and Preliminary Patency of Prophylactic Hypogastric Artery Stenting for Prevention of Spinal Cord Ischemia in Complex Endovascular Aortic RepairAnnals of Vascular Surgery, 2021
- Comprehensive Review of Physician Modified Aortic Stent Grafts: Technical and Clinical OutcomesEuropean Journal of Vascular and Endovascular Surgery, 2021
- Sequential Catheterization and Progressive Deployment of the Zenith® t-Branch™ Device for Branched Endovascular Aortic Aneurysm RepairCardioVascular and Interventional Radiology, 2020
- Staged procedures for prevention of spinal cord ischemia in endovascular aortic surgeryGefässchirurgie, 2018
- First-in-man endovascular preconditioning of the paraspinal collateral network by segmental artery coil embolization to prevent ischemic spinal cord injuryThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Editor's Choice – Temporary Aneurysm Sac Perfusion as an Adjunct for Prevention of Spinal Cord Ischemia After Branched Endovascular Repair of Thoracoabdominal AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2014
- Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and ResultsCardioVascular and Interventional Radiology, 2013
- The collateral network concept: A reassessment of the anatomy of spinal cord perfusionThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Staged repair significantly reduces paraplegia rate after extensive thoracoabdominal aortic aneurysm repairThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Spinal cord perfusion after extensive segmental artery sacrifice: can paraplegia be prevented?European Journal of Cardio-Thoracic Surgery, 2007