AGAlessandro Grandi

Alessandro Grandi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alessandro Grandi has a total of 84 co-authors. Here are the top co-authors by number of shared publications:

  • Luca Bertoglio

    Division of Vascular Surgery, Department of Surgical and Clinical Sciences, University and ASST Spedali Civili Hospital of Brescia, Brescia, Italy

    20 shared publications
  • Roberto Chiesa

    Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, "Vita-Salute" San Raffaele University, Milan, Italy

    17 shared publications
  • Germano Melissano

    Department of Vascular Surgery, San Raffaele Scientific Institute, Vita-Salute University, Milano, Italy

    9 shared publications
  • Germano Melissano

    Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, "Vita-Salute" San Raffaele University, Milan, Italy

    7 shared publications
  • Tilo Kölbel

    German Aortic Centre, Department of Vascular Medicine, University Medical Centre Eppendorf, Hamburg, Germany

    7 shared publications
  • Andrea Kahlberg

    Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy

    6 shared publications

Latest Publications

  • Open Access

    Multimodal Endovascular Treatment of Post-Dissection Thoracoabdominal Aneurysm Using Adjunctive Advanced Endovascular Techniques Combined to Branched Repair: Case Report

    by Pietro Dioni, Francesco Colamaria, Alessandro Grandi, Gabriele Piffaretti, Stefano Bonardelli, Luca Bertoglio

    Background and Clinical Significance: Treatment options for chronic type B aortic dissections (TBADs) remain a topic of ongoing debate. Patients with post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs) are typically younger than those with degenerative TAAAs, and their aortas undergo continuous remodeling over their lifetime. Fenestrated/branched endovascular aortic repair (F/B-EVAR) has shown promising results, but it can be challenged by the presence of a narrow true lumen, which hinders navigation and deployment of bridging components. Moreover, the presence of patent segmental arteries originating from the false lumen may prevent aneurysm shrinkage due to persistent flow, which may also result in insufficient spinal cord protection strategies and an increased risk of spinal cord ischemia. Consequently, multiple endovascular interventions are often necessary to address the persistent anatomical changes in these patients. Case Presentation: We present the case of a patient affected by a post-dissecting TAAA who underwent multiple open and endovascular treatment attempts. The presence of prior multiple laparotomies discouraged a new open surgical repair, while the hypertrophic segmental arteries and the presence of a narrow true lumen made standard F/B-EVAR unfeasible. The patient was successfully treated using a combination of different adjunctive advanced endovascular techniques, including minimally invasive segmental artery coil embolization (MiSACE) as a spinal cord preconditioning strategy and prevention of type II endoleak. Moreover, transcatheter electrosurgical septotomy (TES) was used to create a single aortic channel in the presence of a narrow true lumen, which allowed the deployment of a multifeatured, custom-made branched endograft. Conclusions: Endovascular repair of post-dissection TAAAs requires a thorough understanding of advanced endovascular adjuncts, which are often combined to overcome the complex anatomical challenges inherent to this disease. Although encouraging results have been reported, both segmental artery embolization for the indications described here and TES warrant further evaluation in prospective multicenter studies to confirm their safety and efficacy.


  • Open Access

    Staging Strategies During Complex Endovascular Aortic Procedures to Minimize Spinal Cord Ischemia Rates: A Narrative Review

    by Alessandro Grandi, Andrea Melloni, Pietro Dioni, Stefano Bonardelli, Luca Bertoglio

    Endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) requires multidisciplinary expertise to minimize mortality and disabling complications. Despite satisfactory outcomes with this approach being common knowledge, extensive aortic coverage occurring in fenestrated/branched endovascular aortic repair (F/B-EVAR) carries a non-negligible risk of spinal cord ischemia (SCI). Recently, many authors have proposed different endovascular strategies to mitigate the risk of SCI; however, the real effectiveness of these maneuvers is not universally recognized due to a lack of standardized protocols among individual centers. Several adjuncts have been proposed to obtain staged occlusion of segmental aortic branches to promote spinal cord preconditioning. These strategies include proximal thoracic aortic repair (PTAR), temporary aneurysm sac perfusion (TASP), and minimally invasive staged segmental artery coil embolization (MIS2ACE). The present paper aims to provide an overview of the most advanced staging strategies used in high-volume aortic centers, pointing out that it takes meticulous preoperative planning to face every clinical scenario.


  • Open Access

    Staging Strategies During Complex Endovascular Aortic Procedures to Minimize Spinal Cord Ischemia Rates: A Narrative Review

    by Alessandro Grandi, Andrea Melloni, Pietro Dioni, Stefano Bonardelli, Luca Bertoglio

    Endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) requires multidisciplinary expertise to minimize mortality and disabling complications. Despite satisfactory outcomes with this approach being common knowledge, extensive aortic coverage occurring in fenestrated/branched endovascular aortic repair (F/B-EVAR) carries a non-negligible risk of spinal cord ischemia (SCI). Recently, many authors have proposed different endovascular strategies to mitigate the risk of SCI; however, the real effectiveness of these maneuvers is not universally recognized due to a lack of standardized protocols among individual centers. Several adjuncts have been proposed to obtain staged occlusion of segmental aortic branches to promote spinal cord preconditioning. These strategies include proximal thoracic aortic repair (PTAR), temporary aneurysm sac perfusion (TASP), and minimally invasive staged segmental artery coil embolization (MIS2ACE). The present paper aims to provide an overview of the most advanced staging strategies used in high-volume aortic centers, pointing out that it takes meticulous preoperative planning to face every clinical scenario.


  • Open Access

    The Role of Downsizing of Large-Bore Percutaneous Femoral Access for Pelvic and Lower Limb Perfusion in Transfemoral Branched Endovascular Aortic Repair

    by Daour Yousef Al Sarhan, Tilo Kölbel, Alessandro Grandi, Petroula Nana, José I. Torrealba, Christian-Alexander Behrendt, Giuseppe Panuccio

    Background: Transfemoral access (TFA) is a valuable alternative to upper extremity access (UEA) for branched endovascular aortic repair (bEVAR). However, TFA requires large introducer sheaths, which can reduce blood flow to lower limbs and the pelvis. This study aimed to evaluate the efficacy of sheath downsizing to maintain lower limb perfusion during TFA–bEVAR. Methods: A single-center retrospective review was conducted including patients managed with TFA-performed bEVAR between December 2020 and May 2021. Intra-operative lower limb perfusion was assessed using non-invasive ankle blood pressure measurements and great toe pulse oximetry, with measurements being taken prior to puncture (baseline), one minute after 10F-sheath insertion, three minutes after the main body delivery system insertion, and three minutes after downsizing to a 14F sheath. Outcomes included the incidence of limb perfusion reduction (LPR), defined as a drop in the ankle–brachial index (ABI) < 0.5 or peripheral oxygen saturation (SpO2) < 90%. Results: Out of 47 patients, 24 met the inclusion criteria. LPR occurred in 4.2% of cases after 10F-sheath placement, and 87.5% after main body delivery system placement, and decreased to 12.6% after downsizing to a 14F sheath. No periprocedural major bleeding occurred. Two patients required revision for inadequate hemostasis post-operatively. SCI occurred in 16% of patients, all recovered by discharge. Pre-operative hypogastric artery occlusion was related to persistent LPR after downsizing (100% vs. 16%, p = 0.009). Conclusions: Downsizing the introducer sheath during bEVAR is feasible and safe to restore lower limb and pelvic perfusion. Further research is needed to clarify the access downsizing value during bEVAR.


  • Physician-Modified Reversed Iliac Branch Device to Prevent Spinal Cord Ischemia in an Urgent Branched Endovascular Aortic Repair

    by Karolina Malik, Tilo Kölbel, Alessandro Grandi, Jose Torrealba, Fiona Rohlffs, Giuseppe Panuccio

    Purpose: Repair of pararenal aneurysms poses a challenge, especially in an urgent setting. Despite the minimally invasive nature of the fenestrated/branched endovascular aortic repair, the technique may require extensive coverage of the aorta, increasing the risk of spinal cord ischemia. Technique: A 68-year-old man was admitted with a rapid enlargement of an asymptomatic juxtarenal aortic aneurysm. A minimally invasive treatment with an off-the-shelf branched endovascular graft was planned. Before completing the aneurysm exclusion, an angiography highlighted a large lumbar artery, potentially significant for the perfusion of the spinal cord collateral network. Owing to this finding and an unsuccessful placement of the cerebrospinal fluid drainage, the procedure was staged and completed 5 days later using a physician-modified iliac branch device (IBD) for the segmental artery. The device was shortened and reversely loaded to obtain a cranially-oriented branch. A balloon-expandable covered stent was used to connect the retrograde branch (8 mm) to the lumbar artery (4 mm). Pre-discharge computed tomography (CT)-angiography confirmed the vessel patency. No neurological symptoms occurred. Conclusion: The use of a reversely-loaded IBD for segmental artery preservation appears feasible and safe. Clinical Impact: Intraoperative modification of an iliac branch device during an urgent branched endovascular aortic repair enabled preservation of a potentially critical segmental artery, thus reducing the risk of spinal cord ischemia. This adaptive interventional technique may also offer a strategy for preserving other anatomically significant vessels, such as accessory renal arteries, during complex aortic reconstructions in urgent settings.


  • Open Access

    Unintended Exchange of Target Vessels for Celiac Trunk and Superior Mesenteric Artery Branches in Complex Endovascular Aortic Repair

    by Florian K. Enzmann, Alessandro Grandi, Giuseppe Panuccio, José Ignacio Torrealba, Michaela Kluckner, Petroula Nana, Fiona Rohlffs, Tilo Kölbel

    Purpose: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. Materials and Methods: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. Results: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1–15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9–22) days with a median of 4 (IQR: 2–11) days at the intensive care unit. Conclusion: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. Clinical Impact: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.


  • Open Access

    Dilated Internal Iliac Artery Confers a Higher Risk of Endoleak in Iliac Branch Devices in a Single Centre Retrospective Experience

    by Jose I. Torrealba, Alessandro Grandi, Petroula Nana, Giuseppe Panuccio, Fiona Rohlffs, Tilo Kölbel


  • Transfemoral Access to Implant Iliac Branch Devices After Previous Aortic Grafts

    by Jose Torrealba, Alessandro Grandi, Petroula Nana, Giuseppe Panuccio, Fiona Rohlffs, Tilo Kölbel

    Objective: To report on the outcomes of patients undergoing an iliac branch device implantation after previous open or endovascular aorto-biliac repair, using exclusively femoral access for catheterization and delivery of the covering stent to the hypogastric artery. Methods: Single-center retrospective study in which all patients in whom an iliac branch device was implanted after previous open or endovascular aorto-biliac repair were identified. Patients in whom the hypogastric artery catheterization and delivery of the bridging cover stent were achieved via exclusive femoral access were included. Different techniques were used based on surgeon preference. Technical success and access-related complications, as well as iliac branch device endoleak or occlusions during follow-up, were evaluated. Results: From 2015 to 2021, 28 patients with a prior open or endovascular aorto-biliac repair underwent 34 iliac branch device implantations. Most (71%) had juxtarenal or thoracoabdominal aortic aneurysms, 82% had common iliac artery aneurysms, and 25% had hypogastric artery aneurysms. Bilateral iliac branch device implantations were performed in 21% of the patients, and in 26% of cases, landing in the superior gluteal artery was obtained. An “up-and-over” technique from the contralateral groin was used in 65% of the cases, and a steerable sheath in 35%. Technical success was 94%, with no complications related to access or technique to catheterize and deliver the stents in the hypogastric artery. The cohort had 20% of major complications, with 3 perioperative deaths. Kaplan–Meier estimated an iliac branch device freedom from occlusion and endoleak was 92% and 83% at 2 years. Conclusions: The implantation of an iliac branch device over previous aortic or open endografts involving the aortic bifurcation is feasible and safe. We suggest using a femoral approach as the primary access of choice. Clinical Impact: In this study we present 28 patients with previous aortoiliac grafts in which iliac branch devices were performed as a subsequent step.We demonstrated the feasibility of the technique despite the difficulty of crossing a neobifurcation, with a steep angle, without complications associated with the technique. Based on our experience, we recommend transfemoral access as the first option for bypassing the hypogastric artery stent, preserving upper extremity access and its possible complications.


  • Open Access

    Ascending Aorta Nose-Cone Loop Technique as Bail Out for Precise Branched Endovascular Aortic Arch Endograft Delivery Without Valve Re-Crossing

    by Alessandro Grandi, Tilo Kölbel, Fiona Rohlffs, Daour Yousef al Sarhan, Giuseppe Panuccio

    Purpose: To describe a right carotid-femoral through-and-through (T&T) guidewire technique during branched thoracic endovascular aortic arch repair (B-TEVAR) to facilitate endograft delivery in a very tortuous aortic anatomy for a type Ia endoleak (EL) of a previous aortic endograft implantation. Technique: AT&T guidewire was established between the right common carotid artery and the right common femoral artery to facilitate a difficult endograft delivery. Once in the aortic arch, a loop in the ascending aorta was formed to allow the endograft to reach the desired position without losing tension on the guidewire. This maneuver allowed the T&T guidewire to be kept in place until the desired position was reached. The nose-tip of the endograft was curved over the looped guidewire pointing toward the innominate artery without crossing the valve. After endograft deployment, the T&T guidewire was released, and the branches were bridged in a standard fashion. Completion angiography documented correct deployment of the endograft and no sign of type I/III EL. The 1-month computed tomography angiography confirmed the correct deployment. Conclusion: Carotid-femoral T&T guidewire to facilitate endograft delivery in difficult anatomies can be feasible even in B-TEVAR. Possible bailout maneuvers are available if the aortic valve needs to be crossed after endograft delivery. Clinical Impact: Endovascular arch repair gains popularity as a valuable alternative, especially in patients considered unfit for open repair. A through-and-through (T&T) guidewire for endovascular arch repair with a landing zone in zone 0 according to Ishimaru is usually performed through the externalization of the femoral guidewire through a transapical access, but this may not always be feasible in frail patients. A right carotid-femoral though-and-through guidewire with a loop formation in the ascending aorta is proposed to achieve the support of a T&T wire to pass tortuous aortoiliac anatomies and access the ascending aorta without the need for aortic valve crossing.


  • Open Access

    Transvenous Access for Emergent Thoracic and Thoracoabdominal Aortic Aneurysm Repair in Patients Without Femoral Access

    by Alessandro Grandi, Catharina Gronert, Giuseppe Panuccio, Fiona Rohlffs, Daour Yousef al Sarhan, Tilo Kölbel

    Purpose: To describe the technique of transvenous access for emergent endovascular repair of thoracic and thoracoabdominal aneurysms exemplified with 2 cases. Technique: Transvenous access to the aorta is described as an alternative access method to deliver aortic endografts in emergency situations. A 68-year-old female patient with severely compromised iliac and subclavian artery access was treated for a ruptured extent V thoraco-abdominal aortic aneurysm with a t-Branch (Cook Medical, Bjaeverskov, Denmark) delivered through a transcaval access. To avoid severe aortocaval shunting a balloon-expandable covered stent was deployed through a carotid access due to severe bilateral subclavian ostial stenosis. A 71-year-old man with an acute type B aortic dissection and bilateral narrow long-segment stenting of the iliac arteries was treated with a physician-modified thoracic endovascular aortic repair using an arteriovenous fenestration created at the level of the common iliac artery. We describe the access creation by fenestration using a transseptal needle. Conclusion: Transvenous access for thoracic and thoraco-abdominal aortic aneurysm repair is safe and feasible in selected emergent cases. Clinical Impact: A transvenous approach may be helpful in selected patients when an endovascular repair needs to be performed but no arterial femoral access is available. This approach proved to be feasible even with large-bore introducer sheaths, taking its place in the armamentarium of the vascular surgeon for emergent complex endovascular aortic repairs.