Visualization and evaluation of the quality variations of EBT4 Gafchromic film using multidimensional scaling and Lie derivative image analysis
Authors:
- 6 May 2025
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (2) , 797-811
Abstract
Film-specific uniformity variations in packages are known to significantly diminish the effectiveness of the one-scan protocol, a commonly used film dosimetry method. This method universally adopts the reference dose–response with rescaling linearly from the relationship of the known dose and the unexposed state. This study aims to visualize and quantify the variation in unexposed film-specific uniformity in a package to evaluate the suitability of the reference dose response using machine-learning method. Fourteen EBT4 films (#00–#13) were selected from two lot packages. Nine grid-spaced 100 × 100 pixel (72 dpi) patches were obtained from the color images of EBT4 film sheet using a single scanner with landscape (scan A) and portrait (scan B) scan orientations. The reference patch was set at the center of film #00. For this study, multidimensional scaling (MDS) and Lie derivative image analysis (LDIA) were applied to the patch data with respect to the red (R)/green (G)/blue (B) channels. MDS is a suitable method for analyzing non-linear data with similarity, which provides a map of data objects according to a distance metric. LDIA directly detects the deviation vector field between image gradients. The film-specific uniformity was measured at 1/10000 scaled pixel value as a scalar distribution. The image flow field was obtained as a negative gradient of the scalar distribution. Two similarity metrics were defined for comparison with the reference patch: (1) MDSr (the distance parameter in the MDS map from the origin) and (2) Stot (summed S-value in each patch, where S-value represents the vorticity of the deviation vector field obtained via the Lie derivative). MDSr highly correlated with the absolute pixel value difference from the reference patch except for the blue channel in which a favorable package was detected for the reference dose response. Stot quantified the film-uniformity variation from the reference, independent of the dataset, and detected the unfavorable film state as Stot < 0.8 in the blue channel. We visualized and quantified the variation in film-specific uniformity in a lot package using MDS and LDIA, thereby quantitatively determining the unfavorable condition for applying the reference dose–response.Keywords
Funding Information
- Japan Society for the Promotion of Science (22H03021, 25K19118)
This publication has 53 references indexed in Scilit:
- Investigating the method of selection of background pixel values for the calibration of EBT‐XD film dosimetryPrecision Radiation Oncology, 2024
- Comprehensive evaluation and new recommendations in the use of Gafchromic EBT3 filmMedical Physics, 2023
- Characterization of GafchromicTM EBT4 film with clinical kV/MV photons and MeV electronsPrecision Radiation Oncology, 2023
- Characterization of scanning orientation and lateral response artifact for EBT4 Gafchromic filmJournal of Applied Clinical Medical Physics, 2023
- Technical note: Energy dependence of the Gafchromic EBT4 film: Dose‐response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x‐ray beamsMedical Physics, 2023
- Assessment of using a gamma index analysis for patient‐specific quality assurance in JapanJournal of Applied Clinical Medical Physics, 2022
- Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55Medical Physics, 2020
- Tolerance limits and methodologies forIMRTmeasurement‐based verificationQA:Recommendations ofAAPMTask Group No. 218Medical Physics, 2018
- Interpretation of image flow: Rigid curved surfaces in motionInternational Journal of Computer Vision, 1988
- Multidimensional Scaling: I. Theory and MethodPsychometrika, 1952