The technique for retrieving a fully migrated pancreatic duct stent using a snare placed over the proximal end of biopsy forceps

Authors:

Abstract
Pancreatic stents (PSs) are predominantly used to treat pancreatitis and pancreatic duct (PD) stenosis. However, stent migration is occasional. Several methods have been reported for migrated PS retrieval [1] [2] [3] [4] [5], but removal remains challenging, as excessive manipulation increases the risk of duct injury and pancreatitis. A 70-year-old woman with acute pancreatitis developed distal PD stenosis and a pseudocyst, for which a PS (7 Fr × 12 cm) was inserted ([Fig. 1]). PS insertion resulted in pseudocyst size reduction ([Fig. 2]). After 3 months, endoscopic retrograde cholangiopancreatography was performed to examine the stenosis. During the procedure, the PS was grasped with rat-tooth forceps but adhered firmly at the stenotic site. Attempted traction caused damage and migration completely into the PD ([Fig. 3]). Standard forceps could not be inserted because of mild PD dilation. Furthermore, retrieval using a balloon catheter was unsuccessful after multiple attempts. Fluoroscopic guidance allowed small-caliber biopsy forceps (BF) to grasp the damaged portion of the stent; however, extraction was not possible. Strong traction resulted in a loss of grasp. The damaged portion was grasped again with BF, but repeated attempts posed an increased risk of pancreatitis without guaranteeing success. BF provided excellent maneuverability, but its grasping force was limited. To overcome this challenge, we developed a snare-assisted retrieval method using a snare while maintaining a BF grasp. In this method, a snare (thin-diameter crescent snare, Olympus) was guided through the proximal end of the forceps to the stent, securing it while maintaining the BF hold. The stent was successfully retrieved without complications ([Fig. 4]). Postprocedure pancreatography revealed no significant PD injury ([Video 1]). When BF traction alone is insufficient, the snare-assisted technique enables direct endoscopic visualization, thereby minimizing unnecessary manipulation within the PD. This approach represents a simple, safe, and effective method of stent retrieval without compromising BF maneuverability. Endoscopy_UCTN_Code_TTT_1AR_2AI Article published online: 15 April 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany