YKYuki Kawasaki

Yuki Kawasaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuki Kawasaki has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Snare-assisted double pancreatic duct stenting for severe pancreatic stricture

    by Kazuya Sumi, Jun Ushio, Tomoya Sato, Hisaki Kato, Yuki Kawasaki, Takayoshi Ito, Haruhiro Inoue

  • Open Access

    Endoscopic full-thickness retrieval of a migrated plastic stent after endoscopic ultrasonography-guided liver abscess drainage

    by Kazuya Sumi, Jun Ushio, Hisaki Kato, Yuki Kawasaki, Takayoshi Ito, Yoshio Deguchi, Haruhiro Inoue

  • Open Access

    A Novel Closure Technique after Endoscopic Papillectomy Using the Endoscopic Purse-String Suture Device

    by Yuki Kawasaki, Hisaki Kato, Kazuya Sumi, Jun Ushio, Takayoshi Ito, Noboru Yokoyama, Haruhiro Inoue

    Endoscopic papillectomy (EP) is a therapeutic option for tumors of the duodenal papilla; however, it is associated with adverse events such as bleeding and perforation.[1] Although closure of the post-EP ulcer after biliary and pancreatic stent placement is generally attempted with clips, achieving complete closure remains challenging.[2] [3] The usefulness of a novel endoscopic purse-string suture technique, “Loop 9,” for closure after gastrointestinal endoscopic submucosal dissection has previously been reported,[4] [5] and a ready-to-use device for this technique has become available ([Fig. 1]). Using this device, we achieved a tighter closure with less dead space than conventional methods for a post-EP ulcer. A woman in her 50 s was referred for evaluation of bile duct dilatation. Computed tomography, esophagogastroduodenoscopy, endoscopic ultrasonography, and biopsy revealed an ampullary tumor suitable for EP. After snare papillectomy and specimen retrieval, biliary and pancreatic stents were placed. The loop thread of Loop 9 was positioned over both stents and fixed with clips. Clips were then applied to the anterior and posterior walls on both the distal and proximal sides of the stents ([Fig. 2]). Finally, the knot at the distal end of Loop 9 was grasped with biopsy forceps and pulled into the sheath; the plastic pledget served as an anchor, allowing the loop to be tightened ([Fig. 2]). The patient was discharged without adverse events, including delayed bleeding. Two weeks later, the stents were removed, and sufficient healing of the ulcer was confirmed ([Fig. 3]). Loop 9 enabled closure of the proximal side of the stents, which is difficult with conventional clip closure. Suturing around the stents may also prevent stent migration and help reduce bleeding and early stenosis of the bile and pancreatic duct orifices ([Fig. 4]). This simple and reproducible technique may represent a useful new approach to post-EP closure ([Video 1]). Video 1 Closure of a post-endoscopic papillectomy ulcer using the endoscopic purse-string suture device. Endoscopy_UCTN_Code_CPL_1AH_2AL Received: 05 May 2026 Accepted after revision: 28 May 2026 Article published online: 11 June 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Successful endoscopic sphincterotomy using a rotatable sphincterotome in a patient with situs inversus totalis

    by Kenshin Tamura, Yuki Kawasaki, Hisaki Kato, Kazuya Sumi, Jun Ushio, Noboru Yokoyama, Haruhiro Inoue

    None Received: 27 January 2026 Accepted after revision: 18 February 2026 Accepted Manuscript online: 19 February 2026 © . The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Usefulness of a Gel‐Mixed Contrast Agent for Gastrointestinal Fluoroscopic Imaging and Stent Placement

    by Yuki Kawasaki, Jun Ushio, Haruhiro Inoue

    Watch a video of this article.

  • Open Access

    Usefulness of a One‐step Semi‐deployment Flushing and Stenting Technique in Endoscopic Transpapillary Gallbladder Drainage for Acute Cholecystitis (With Video)

    by Yuki Kawasaki, Jun Ushio, Hisaki Kato, Kazuya Sumi, Yuki Shibata, Norihiro Nomura, Junichi Eguchi, Takayoshi Ito, Haruhiro Inoue

    Objectives: Endoscopic transpapillary gallbladder stenting (EGBS) has demonstrated high technical and clinical success rates in endoscopic transpapillary gallbladder drainage (ETGBD) for acute cholecystitis. The effectiveness of a 5‐Fr endoscopic naso‐gallbladder drainage (ENGBD) tube for flushing and the internal fistula technique after tube cutting has also been reported. We developed an alternative one‐step semi‐deployed flushing and stenting technique for EGBS using a 7‐Fr pigtail stent that avoids tube resection and evaluated its effectiveness and safety compared with that of endoscopic nasogastric gallbladder drainage. Methods: We retrospectively evaluated 30 patients who underwent ETGBD for acute cholecystitis between April 2023 and November 2024. Results: The technical and clinical success rates of the one‐step semi‐deployment flushing and stenting techniques were 95.2% (20/21) and 100% (20/20), respectively. No adverse events were reported. The procedure time did not differ significantly from that of ENGBD. Conclusions: EGBS using one‐step semi‐deployment flushing and stenting is a simple and effective treatment for acute cholecystitis in patients with ETGBD.


  • Open Access

    Retrieval of a migrated biliary stent using a customized goose-neck snare

    by Kazuya Sumi, Hisaki Kato, Yukiko Okada, Yuki Kawasaki, Jun Ushio, Takayoshi Ito, Haruhiro Inoue

    Stents are commonly used to treat acute cholangitis (AC) and obstructive jaundice caused by strictures of the bile duct (BD) and pancreatic duct. Although rare, stent migration can occur. Stent retrieval is often attempted using forceps, baskets, or balloon catheters; however, the efficacy and reliability of these methods are limited, rendering the retrieval challenging. Several alternative techniques have been reported, including cases where metal and plastic stents (PS) were involved [1] [2] [3] [4]. A woman in her 80s presented with abdominal pain and was diagnosed with AC. Endoscopic retrograde cholangiopancreatography (ERCP) was planned. She had a history of cholangitis several years earlier, during which stone extraction was difficult due to multiple large common bile duct stones, and a PS was placed ([Fig. 1]). In the initial ERCP, removal with grasping forceps failed due to firm adhesion to stones, resulting in stent fracture. Another PS was inserted for drainage, and a second ERCP was planned. After removing the second PS, the initial one was found to have completely migrated. Given its firm adhesion, strong traction was necessary for retrieval. As the proximal BD was filled with multiple large stones, it was necessary for the stent to be grasped in the BD’s open space using a customized gooseneck-shaped snare. To maintain reliable bending and axial control, the tip of a rotatable snare was fixed to the sheath using nylon thread ([Fig. 2]). The snare was inserted over a guidewire and deployed, allowing strong traction with easy grasping and successful PS removal ([Fig. 3], [Fig. 4], [Video 1]). Manually bent snares have been reported; however, the curved shape often reverts upon sheath retraction [5]. Our method offers consistent bending and precise axial control. Snare size can be selected based on duct diameter, and no special equipment is required, making this a simple, reproducible approach. Endoscopy_UCTN_Code_TTT_1AR_2AH Article published online: 11 September 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    Intraoperative closure of a large colonic perforation using dual adjustable instrument and channel endoscopy

    by Kazuya Sumi, Yuki Kawasaki, Hisaki Kato, Taro Tanabe, Masayuki Isozaki, Noboru Yokoyama, Haruhiro Inoue

    Various techniques have been reported for closing perforations and defects following endoscopic procedures [1] [2] [3] [4] [5], with dual-channel endoscopy being one of them. However, its availability is limited, and the fixed orientation of the forceps channel restricts its flexibility. Dual adjustable instrument and channel endoscopy (DAICE) is a novel approach for closing large defects. DAICE converts the standard endoscope into an adjustable dual-channel system with an external channel hood (ECH; Top Corporation, Tokyo, Japan) aligned to the defect. A woman in her 60s who had undergone the Hartmann’s procedure for sigmoid colon diverticular perforation was admitted for colostomy closure and anastomosis. A full-thickness upper rectal tear on the mesenteric side was noted during transanal anastomosis ([Fig. 1]). Given the anatomical location, direct surgical closure was deemed technically unfeasible ([Fig. 2]). Consequently, intraoperative endoscopic closure was planned. Closure with an over-the-scope clip was not feasible owing to the large defect size and the fixed channel orientation hindered proper clip engagement on the deeper edge of the defect. To overcome this, DAICE was developed by attaching an ECH to the standard endoscope, allowing positional adjustment. One side of the defect was grasped using a rat tooth forceps and brought closer to the opposite side. The clips were inserted through the external channel, starting from the posterior edge, to close the defect ([Fig. 3], [Fig. 4]). The procedure was completed after confirming no air leaks and complete closure without luminal stenosis ([Fig. 5], [Video 1]). DAICE is effective for closure, and is versatile and applicable in various scenarios. The 2.8-mm guide tube of the external channel is compatible with a range of devices, enabling its various clinical applications. The ECH can be attached easily, and the procedure can be performed with conventional endoscopes, eliminating the need for dual-channel endoscopy, thereby reducing cost. Endoscopy_UCTN_Code_CPL_1AJ_2AG Article published online: 02 July 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    A pancreaticobiliary fistula due to pancreatic stones in long-term follow-up of chronic pancreatitis

    by Kazuya Sumi, Jun Ushio, Takahiro Miyake, Hisaki Kato, Yuki Kawasaki, Takayoshi Ito, Haruhiro Inoue

    Pancreaticobiliary fistulas (PBFs) are rare and associated with pseudocysts or intraductal papillary mucinous neoplasms [1] [2] [3]. We report the case of a patient suffering from a PBF caused by pancreatic stones (PSs) that developed during the long-term course of chronic pancreatitis (CP). The stones migrated into the bile duct (BD). The patient was treated by fragmenting the PSs by cholangioscopy, followed by covered self-expanding metal stent (CSEMS) and pancreatic duct (PD) stent placement to facilitate PBF closure. A man aged 40 years with chronic alcoholic pancreatitis, PSs, and PD stenosis ([Fig. 1] a–c) underwent repeated endoscopic PD dilations and stent placements to manage complications ([Fig. 2]). After 1 year of PD stent removal, he presented with fever. Computed tomography revealed liver abscess, and percutaneous drainage was performed. Biliary compression due to PSs, infection, abscess, and biloma were suspected, prompting endoscopic retrograde cholangiopancreatography (ERCP). Biliary cannulation was successfully performed during ERCP, and a guidewire was advanced through the PBF. Endoscopic cholangiography was performed with contrast to visualize the PD via the PBF, which revealed distal BD stenosis. Biliary and PD stents were placed and cholangioscopy was scheduled ([Fig. 3] a–c). Follow-up cholangioscopy performed after 2 months revealed biliary stenosis caused by a large white PS. Direct cholangioscopy-guided electrohydraulic lithotripsy, which was performed for fragmenting and extracting the PS, revealed a PBF within the BD. Subsequently, a CSEMS was placed in the BD with the simultaneous plastic stent placement in the PD ([Fig. 4] a–c). However, an ERCP performed 4 months later indicated PBF persistence ([Fig. 5]; [Video 1]). To the best of our knowledge, PSs have not been reported to directly cause PBF formation in CP. Given the large fistula, spontaneous closure was not achieved, and surgical treatment was considered. This status is indicative of pancreaticobiliary ductal malfunction and warrants appropriate follow-up. Endoscopy_UCTN_Code_TTT_1AR_2AI Article published online: 15 April 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    The technique for retrieving a fully migrated pancreatic duct stent using a snare placed over the proximal end of biopsy forceps

    by Kazuya Sumi, Naoya Patrick Terai, Hisaki Kato, Yuki Kawasaki, Jun Ushio, Takayoshi Ito, Haruhiro Inoue

    Pancreatic stents (PSs) are predominantly used to treat pancreatitis and pancreatic duct (PD) stenosis. However, stent migration is occasional. Several methods have been reported for migrated PS retrieval [1] [2] [3] [4] [5], but removal remains challenging, as excessive manipulation increases the risk of duct injury and pancreatitis. A 70-year-old woman with acute pancreatitis developed distal PD stenosis and a pseudocyst, for which a PS (7 Fr × 12 cm) was inserted ([Fig. 1]). PS insertion resulted in pseudocyst size reduction ([Fig. 2]). After 3 months, endoscopic retrograde cholangiopancreatography was performed to examine the stenosis. During the procedure, the PS was grasped with rat-tooth forceps but adhered firmly at the stenotic site. Attempted traction caused damage and migration completely into the PD ([Fig. 3]). Standard forceps could not be inserted because of mild PD dilation. Furthermore, retrieval using a balloon catheter was unsuccessful after multiple attempts. Fluoroscopic guidance allowed small-caliber biopsy forceps (BF) to grasp the damaged portion of the stent; however, extraction was not possible. Strong traction resulted in a loss of grasp. The damaged portion was grasped again with BF, but repeated attempts posed an increased risk of pancreatitis without guaranteeing success. BF provided excellent maneuverability, but its grasping force was limited. To overcome this challenge, we developed a snare-assisted retrieval method using a snare while maintaining a BF grasp. In this method, a snare (thin-diameter crescent snare, Olympus) was guided through the proximal end of the forceps to the stent, securing it while maintaining the BF hold. The stent was successfully retrieved without complications ([Fig. 4]). Postprocedure pancreatography revealed no significant PD injury ([Video 1]). When BF traction alone is insufficient, the snare-assisted technique enables direct endoscopic visualization, thereby minimizing unnecessary manipulation within the PD. This approach represents a simple, safe, and effective method of stent retrieval without compromising BF maneuverability. Endoscopy_UCTN_Code_TTT_1AR_2AI Article published online: 15 April 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany