Repeated or long-duration TASER® electronic control device exposures: acidemia and lack of respiration
- 20 November 2009
- journal article
- review article
- Published by Springer Nature in Forensic Science, Medicine and Pathology
- Vol. 6 (1) , 46-53
Abstract
Conducted energy weapons (CEWs), such as TASER® devices, may be applied to subjects in repeated or long-duration modes. Such applications may result in more potentially harmful effects (as reflected in blood factor changes) than shorter exposures. In this review, results from a number of studies of repeated and long-duration CEW exposures in an animal model are examined. Additionally, a few limited investigations of shorter CEW applications to human subjects are considered. Specifically, in anesthetized swine, increased blood acidity (acidemia) and lack of effective respiration were found to be common during or immediately after CEW exposure. The acidemia could have been due to both metabolic and respiratory acidosis. A relatively rapid recovery toward baseline pH levels occurred. The lack of effective respiration has not been verified in experiments of CEW applications to human subjects; however, in some incidents of human deaths after CEW exposures subjects have been reported to stop breathing immediately after the exposure. It is not known if all human subjects exposed to CEW applications in the field (often “on drugs” or “in excited delirium”) would be able to maintain adequate breathing. Since a limited number of short CEW applications would be less likely to cause adverse effects, however, CEWs can still be a valuable tool for law enforcement activities.Keywords
This publication has 65 references indexed in Scilit:
- 75: The Effect of a Cross-Chest Electronic Control Device Exposure on BreathingAnnals of Emergency Medicine, 2008
- Electronic control devicesCanadian Medical Association Journal, 2008
- In replyAnnals of Emergency Medicine, 2008
- Taser Safety Remains UnclearAnnals of Emergency Medicine, 2008
- Cardiac stimulation with high voltage discharge from stun gunsCanadian Medical Association Journal, 2008
- The Physiologic Effects of a Conducted Electrical Weapon in SwineAnnals of Emergency Medicine, 2007
- Physiological Effects of a Conducted Electrical Weapon on Human SubjectsAnnals of Emergency Medicine, 2007
- Delayed lethal arrhythmia after an electrical injuryEmergency Medicine Journal, 2007
- Repeated Thoracic Discharges From a Stun Device2007
- Effects of stun guns and tasersThe Lancet, 2001