James R. Jauchem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
James R. Jauchem has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Kathy L. Ryan
US Army Institute of Surgical Research, Joint Base San Antonio, Fort Sam Houston, TX, USA
6 shared publicationsM R Frei
6 shared publicationsMelvin R. Frei
Department of Biology, Trinity University, San Antonio, Texas
6 shared publicationsMichael C. Cook
U.S. Air Force Research Laboratory, TX, USA
5 shared publications- Melvin R. Frei
Department of Biology, Trinity University, San Antonio, Texas
4 shared publications Ronald L. Seaman
4 shared publications
Latest Publications
- 17 September 2015
- Published by Walter de Gruyter GmbH in Journal of Basic and Clinical Physiology and Pharmacology
- Vol. 27 (1) , 79-89
Pathophysiological alterations induced by sustained 35-GHz radio-frequency energy heating
Background: Exposure to radio-frequency energy (RFE) of millimeter wavelengths results in a relatively high skin-heating rate, with only a moderate rate of core heating. Yet, prolonged RFE exposure eventuates in severe hypotension and death. In this study, we characterized pathophysiological changes associated with prolonged RFE sufficient to induce hypotension. Methods: Anesthetized rats were exposed to 35-GHz RFE with a power density of 75 mW/cm 2 . Cardiovascular and temperature parameters were continuously recorded. Blood factors and histopathology were compared between sham (n=6) and exposed (n=12) animals. Results and conclusions: Using infrared thermography, we confirmed a relatively high temperature (>46 °C) at the skin surface of the irradiated site. Histopathological results included hemorrhage and congestion of blood vessels in the dermis and subcutis of irradiated skin without induction of burn. As in environmental heating, significantly greater levels of serum glucose, creatinine, uric acid, and anion gap were observed in rats exposed to longer-duration RFE (approx. 38-min exposures) than in shorter-duration (approx. 19-min exposures) or sham (time control) animals. However, changes in blood electrolytes or liver enzymes (often seen during heatstroke) were not observed after the RFE exposures. Even without major tissue injury or serum/plasma enzyme and electrolyte changes, rapid cutaneous heating via RFE induced profound hypotension that eventuated in death.
- 17 September 2015
- Published by Walter de Gruyter GmbH in Journal of Basic and Clinical Physiology and Pharmacology
- Vol. 27 (1) , 79-89
Pathophysiological alterations induced by sustained 35-GHz radio-frequency energy heating
Background: Exposure to radio-frequency energy (RFE) of millimeter wavelengths results in a relatively high skin-heating rate, with only a moderate rate of core heating. Yet, prolonged RFE exposure eventuates in severe hypotension and death. In this study, we characterized pathophysiological changes associated with prolonged RFE sufficient to induce hypotension. Methods: Anesthetized rats were exposed to 35-GHz RFE with a power density of 75 mW/cm 2 . Cardiovascular and temperature parameters were continuously recorded. Blood factors and histopathology were compared between sham (n=6) and exposed (n=12) animals. Results and conclusions: Using infrared thermography, we confirmed a relatively high temperature (>46 °C) at the skin surface of the irradiated site. Histopathological results included hemorrhage and congestion of blood vessels in the dermis and subcutis of irradiated skin without induction of burn. As in environmental heating, significantly greater levels of serum glucose, creatinine, uric acid, and anion gap were observed in rats exposed to longer-duration RFE (approx. 38-min exposures) than in shorter-duration (approx. 19-min exposures) or sham (time control) animals. However, changes in blood electrolytes or liver enzymes (often seen during heatstroke) were not observed after the RFE exposures. Even without major tissue injury or serum/plasma enzyme and electrolyte changes, rapid cutaneous heating via RFE induced profound hypotension that eventuated in death.
- 1 June 2011
- Published by Wolters Kluwer Health in American Journal of Forensic Medicine & Pathology
- Vol. 32 (2) , 124-130
Survival of Anesthetized Sus scrofa After Cycling (7-Second On/3-Second Off) Exposures to an Electronic Control Device for 3 Minutes
Electronic control devices (ECDs) may eventually be deployed by the military in a manner resulting in longer exposures than those encountered during law-enforcement operations. In a previous study, 18 repeated cycling (5-second on/5-second off) exposures (within a 3-minute period) of anesthetized swine to an ECD (TASER International's Advanced TASER X26 device) resulted in leg muscle contraction, acidosis, and increases in blood electrolytes. In the current study, experiments were performed to examine effects of exposures to a different cycling rate (7-second on/3-second off), from a modified X26 ECD, on 10 swine (Sus scrofa), maintained on propofol anesthesia. In contrast with the previous study, a large number of animals (6/10) died immediately after the exposures. There were no major differences in pre-exposure blood factors from survivors versus nonsurvivors, with the exception of hematocrit and 2 isoenzymes of lactate dehydrogenase. It is doubtful that these factors would be useful in predicting survival after ECD exposure. Blood pH was significantly decreased after exposure, but (in animals that survived) subsequently returned to baseline levels. On the basis of the overall survival rate, further development of useful ECDs (for long-term incapacitation during military operations) may require consideration of longer pauses between repeated exposures over a 3-minute period.
- 1 June 2011
- Published by Wolters Kluwer Health in American Journal of Forensic Medicine & Pathology
- Vol. 32 (2) , 124-130
Survival of Anesthetized Sus scrofa After Cycling (7-Second On/3-Second Off) Exposures to an Electronic Control Device for 3 Minutes
Electronic control devices (ECDs) may eventually be deployed by the military in a manner resulting in longer exposures than those encountered during law-enforcement operations. In a previous study, 18 repeated cycling (5-second on/5-second off) exposures (within a 3-minute period) of anesthetized swine to an ECD (TASER International's Advanced TASER X26 device) resulted in leg muscle contraction, acidosis, and increases in blood electrolytes. In the current study, experiments were performed to examine effects of exposures to a different cycling rate (7-second on/3-second off), from a modified X26 ECD, on 10 swine (Sus scrofa), maintained on propofol anesthesia. In contrast with the previous study, a large number of animals (6/10) died immediately after the exposures. There were no major differences in pre-exposure blood factors from survivors versus nonsurvivors, with the exception of hematocrit and 2 isoenzymes of lactate dehydrogenase. It is doubtful that these factors would be useful in predicting survival after ECD exposure. Blood pH was significantly decreased after exposure, but (in animals that survived) subsequently returned to baseline levels. On the basis of the overall survival rate, further development of useful ECDs (for long-term incapacitation during military operations) may require consideration of longer pauses between repeated exposures over a 3-minute period.
- 1 May 2011
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 18 (4) , 145-153
Pathophysiologic changes due to TASER® devices versus excited delirium: Potential relevance to deaths-in-custody?
- 1 May 2011
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 18 (4) , 145-153
Pathophysiologic changes due to TASER® devices versus excited delirium: Potential relevance to deaths-in-custody?
- 23 December 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (s1) , S229-S233
Increased Hematocrit After Applications of Conducted Energy Weapons (Including TASER® Devices) to Sus scrofa*
Conducted energy weapons (CEWs) are used by law enforcement personnel to incapacitate individuals quickly and effectively, without intending to cause lethality. CEWs have been deployed for relatively long or repeated exposures in some cases. In laboratory animal models, central venous hematocrit has increased significantly after CEW exposure. Even limited applications (e.g., three 5-sec applications) resulted in statistically significant increases in hematocrit. Preexposure hematocrit was significantly higher in nonsurvivors versus survivors after more extreme CEW applications. The purpose of this technical note is to address specific questions that may be generated when examining these results. Comparisons among results of CEW applications, other electrical muscle stimulation, and exercise/voluntary muscle contraction are included. The anesthetized swine appears to be an acceptable animal model for studying changes in hematocrit and associated red blood cell changes. Potential detrimental effects of increased hematocrit, and considerations during law enforcement use, are discussed.
- 23 December 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (s1) , S229-S233
Increased Hematocrit After Applications of Conducted Energy Weapons (Including TASER® Devices) to Sus scrofa*
Conducted energy weapons (CEWs) are used by law enforcement personnel to incapacitate individuals quickly and effectively, without intending to cause lethality. CEWs have been deployed for relatively long or repeated exposures in some cases. In laboratory animal models, central venous hematocrit has increased significantly after CEW exposure. Even limited applications (e.g., three 5-sec applications) resulted in statistically significant increases in hematocrit. Preexposure hematocrit was significantly higher in nonsurvivors versus survivors after more extreme CEW applications. The purpose of this technical note is to address specific questions that may be generated when examining these results. Comparisons among results of CEW applications, other electrical muscle stimulation, and exercise/voluntary muscle contraction are included. The anesthetized swine appears to be an acceptable animal model for studying changes in hematocrit and associated red blood cell changes. Potential detrimental effects of increased hematocrit, and considerations during law enforcement use, are discussed.
- 15 October 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (s1) , S95-S100
Muscle Contraction During Electro‐muscular Incapacitation: A Comparison Between Square‐wave Pulses and the TASER® X26 Electronic Control Device*
Abstract: Electronic control devices (including the Advanced TASER® X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and swine). Pulse power, electrical pulse charge, pulse duration, and pulse repetition frequency affected muscle contraction. There was no difference in the charge required, between the square waveform and the X26 waveform, to cause approximately the same muscle‐contraction response (in terms of the strength‐duration curve). Thus, on the basis of these initial studies, the detailed shape of a waveform may not be important in terms of generating electro‐muscular incapacitation. More detailed studies, however, may be required to thoroughly test all potential waveforms to be considered for future use in ECDs.
- 15 October 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (s1) , S95-S100
Muscle Contraction During Electro‐muscular Incapacitation: A Comparison Between Square‐wave Pulses and the TASER® X26 Electronic Control Device*
Abstract: Electronic control devices (including the Advanced TASER® X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and swine). Pulse power, electrical pulse charge, pulse duration, and pulse repetition frequency affected muscle contraction. There was no difference in the charge required, between the square waveform and the X26 waveform, to cause approximately the same muscle‐contraction response (in terms of the strength‐duration curve). Thus, on the basis of these initial studies, the detailed shape of a waveform may not be important in terms of generating electro‐muscular incapacitation. More detailed studies, however, may be required to thoroughly test all potential waveforms to be considered for future use in ECDs.
- 1 March 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 55 (2) , 521-526
An Animal Model to Investigate Effectiveness and Safety of Conducted Energy Weapons (Including TASER® Devices)*
Abstract: Conducted energy weapons (CEWs) are used by law‐enforcement personnel to incapacitate individuals quickly and effectively, without causing lethality. CEWs have been deployed for relatively long or repeated exposures during law‐enforcement operations. The purpose of this technical note is to describe, in detail, some aspects of an anesthetized swine model used in our laboratory and to answer specific questions related to the model. In particular, tiletamine/zolazepam‐induced, propofol‐maintained anesthesia appears to be a useful technique for studying effects of CEW applications on muscle contraction and blood factors such as muscle enzymes. Because effects of CEWs on breathing have not been fully elucidated, a spontaneously breathing model is preferable to one in which mechanical ventilation is supplied. Placement of the swine in a supine position may facilitate measurement of muscle contractions, without compromising other physiological parameters.
- 1 March 2010
- Published by Wiley in Journal of Forensic Sciences
- Vol. 55 (2) , 521-526
An Animal Model to Investigate Effectiveness and Safety of Conducted Energy Weapons (Including TASER® Devices)*
Abstract: Conducted energy weapons (CEWs) are used by law‐enforcement personnel to incapacitate individuals quickly and effectively, without causing lethality. CEWs have been deployed for relatively long or repeated exposures during law‐enforcement operations. The purpose of this technical note is to describe, in detail, some aspects of an anesthetized swine model used in our laboratory and to answer specific questions related to the model. In particular, tiletamine/zolazepam‐induced, propofol‐maintained anesthesia appears to be a useful technique for studying effects of CEW applications on muscle contraction and blood factors such as muscle enzymes. Because effects of CEWs on breathing have not been fully elucidated, a spontaneously breathing model is preferable to one in which mechanical ventilation is supplied. Placement of the swine in a supine position may facilitate measurement of muscle contractions, without compromising other physiological parameters.
- Open Access
- 1 January 2010
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 17 (1) , 1-7
Deaths in custody: Are some due to electronic control devices (including TASER® devices) or excited delirium?
- 1 January 2010
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 17 (1) , 1-7
Open AccessDeaths in custody: Are some due to electronic control devices (including TASER® devices) or excited delirium?
- 20 November 2009
- Published by Springer Nature in Forensic Science, Medicine and Pathology
- Vol. 6 (1) , 46-53
Repeated or long-duration TASER® electronic control device exposures: acidemia and lack of respiration
Conducted energy weapons (CEWs), such as TASER® devices, may be applied to subjects in repeated or long-duration modes. Such applications may result in more potentially harmful effects (as reflected in blood factor changes) than shorter exposures. In this review, results from a number of studies of repeated and long-duration CEW exposures in an animal model are examined. Additionally, a few limited investigations of shorter CEW applications to human subjects are considered. Specifically, in anesthetized swine, increased blood acidity (acidemia) and lack of effective respiration were found to be common during or immediately after CEW exposure. The acidemia could have been due to both metabolic and respiratory acidosis. A relatively rapid recovery toward baseline pH levels occurred. The lack of effective respiration has not been verified in experiments of CEW applications to human subjects; however, in some incidents of human deaths after CEW exposures subjects have been reported to stop breathing immediately after the exposure. It is not known if all human subjects exposed to CEW applications in the field (often “on drugs” or “in excited delirium”) would be able to maintain adequate breathing. Since a limited number of short CEW applications would be less likely to cause adverse effects, however, CEWs can still be a valuable tool for law enforcement activities.
- 20 November 2009
- Published by Springer Nature in Forensic Science, Medicine and Pathology
- Vol. 6 (1) , 46-53
Repeated or long-duration TASER® electronic control device exposures: acidemia and lack of respiration
Conducted energy weapons (CEWs), such as TASER® devices, may be applied to subjects in repeated or long-duration modes. Such applications may result in more potentially harmful effects (as reflected in blood factor changes) than shorter exposures. In this review, results from a number of studies of repeated and long-duration CEW exposures in an animal model are examined. Additionally, a few limited investigations of shorter CEW applications to human subjects are considered. Specifically, in anesthetized swine, increased blood acidity (acidemia) and lack of effective respiration were found to be common during or immediately after CEW exposure. The acidemia could have been due to both metabolic and respiratory acidosis. A relatively rapid recovery toward baseline pH levels occurred. The lack of effective respiration has not been verified in experiments of CEW applications to human subjects; however, in some incidents of human deaths after CEW exposures subjects have been reported to stop breathing immediately after the exposure. It is not known if all human subjects exposed to CEW applications in the field (often “on drugs” or “in excited delirium”) would be able to maintain adequate breathing. Since a limited number of short CEW applications would be less likely to cause adverse effects, however, CEWs can still be a valuable tool for law enforcement activities.
- 1 September 2009
- Published by Wiley in Journal of Forensic Sciences
- Vol. 54 (5) , 1113-1118
Pulse Variations of a Conducted Energy Weapon (Similar to the TASER® X26 Device): Effects on Muscle Contraction and Threshold for Ventricular Fibrillation*
Abstract: Conducted energy weapons (such as the Advanced TASER X26 model produced by TASER International), incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, a “Modifiable Electronic Stimulator” was used to evaluate the effects of changing various parameters of the stimulating pulse. Muscle contraction was affected by pulse power, net/gross charge, pulse duration, and pulse repetition frequency. The contraction force increased linearly as each of these factors was increased. Elimination of a precursor pulse from X26‐like pulses did not have a significant effect on the normalized force measured. Muscle‐contraction force increased as the spacing increased from 5 to 20 cm, with no further change in force above 20 cm of spacing. Therefore, it is suggested that any future developments of new conducted energy weapons should include placement of electrodes a minimum of 20 cm apart so that efficiency of the system is not degraded. In the current study, the 50% probability of fibrillation level of X26‐like pulses ranged from 4 to 5 times higher than the X26 itself. Relatively large variations about the X26 operating level were found not to result in fibrillation or asystole. Therefore, it should be possible to design and build an X26‐type device that operates efficiently at levels higher than the X26.
- 1 September 2009
- Published by Wiley in Journal of Forensic Sciences
- Vol. 54 (5) , 1113-1118
Pulse Variations of a Conducted Energy Weapon (Similar to the TASER® X26 Device): Effects on Muscle Contraction and Threshold for Ventricular Fibrillation*
Abstract: Conducted energy weapons (such as the Advanced TASER X26 model produced by TASER International), incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, a “Modifiable Electronic Stimulator” was used to evaluate the effects of changing various parameters of the stimulating pulse. Muscle contraction was affected by pulse power, net/gross charge, pulse duration, and pulse repetition frequency. The contraction force increased linearly as each of these factors was increased. Elimination of a precursor pulse from X26‐like pulses did not have a significant effect on the normalized force measured. Muscle‐contraction force increased as the spacing increased from 5 to 20 cm, with no further change in force above 20 cm of spacing. Therefore, it is suggested that any future developments of new conducted energy weapons should include placement of electrodes a minimum of 20 cm apart so that efficiency of the system is not degraded. In the current study, the 50% probability of fibrillation level of X26‐like pulses ranged from 4 to 5 times higher than the X26 itself. Relatively large variations about the X26 operating level were found not to result in fibrillation or asystole. Therefore, it should be possible to design and build an X26‐type device that operates efficiently at levels higher than the X26.