Estudo morfométrico do atlas
Open Access
- 19 December 2019
- journal article
- research article
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 55 (01) , 062-069
Abstract
Objective To determine the anatomical parameters of the atlas (C1) in a sample of the Brazilian population and compare them with the results already presented in the literature for other populations and, thus, to identify and change the indications of implants used in the treatment of the upper cervical spine. Methods We performed a retrospective observational study of a prospective database, including 100 patients seen between January 2012 and December 2013. We used axial and sagittal sections of computed tomography (CT) scans. The parameters studied were; axial: distance from posterior tubercle to the screw entry point (DPT_EP), safety angle of the axial screw (SA_AS), ideal axial screw length (_ASL) and distance of the spinal canal from the transverse foramen (DSC_TF); Sagittal: ideal sagittal screw length (_SSL), safety angle of the sagittal screw (SA_SS) and posterior arch thickness (_PAT). All of the parameters were divided according to age, gender, and left and right sides. Results The minimum mean point of entry ranged from 20 mm to 22.7 mm. The average security zone ranged from 18.09° to 23.68°. The mean posterior arch thickness ranged from 7.21 mm to 8.95 mm. The lowest averages were found in females. Using an original and reproducible technique of CT evaluation. Conclusion The anatomical parameters of the atlas found in the sample of the studied population were similar to those previously presented in the literature. However, differences between the sexes were observed. ∗ Study developed at the Hospital das Clínicas de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, BrazilKeywords
This publication has 17 references indexed in Scilit:
- Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior archEuropean Spine Journal, 2009
- Relationship Between Screw Trajectory of C1 Lateral Mass Screw and Internal Carotid ArterySpine, 2008
- The Feasibility of Inserting Atlas Lateral Mass Screws via the Posterior ArchSpine, 2006
- Atlantoaxial fixation using the polyaxial screw–rod systemEuropean Spine Journal, 2006
- Posterior Screw Placement on the Lateral Mass of AtlasSpine, 2004
- Morphometric Evaluation of Screw Fixation in Atlas via Posterior Arch and Lateral MassSpine, 2003
- The Equivalence of Weighted Kappa and the Intraclass Correlation Coefficient as Measures of ReliabilityEducational and Psychological Measurement, 1973
- Impressions on the vertebral artery by deformations of the unco-vertebral jointsActa Radiologica, 1957
- THE CERVICAL PORTION OF THE VERTEBRAL ARTERY A CLINICO-PATHOLOGICAL STUDYBrain, 1956
- Fractures and dislocations of the cervical spineThe American Journal of Surgery, 1939