NFNarcelio Mendes Ferreira Filho

Narcelio Mendes Ferreira Filho

*This is an algorithmically generated author record based on publicly available information.

Narcelio Mendes Ferreira Filho has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multimodal Intraoperative Neurophysiological Monitoring in TUBB4A ‐Related Hypomyelinating Leukodystrophy During Scoliosis Correction: A Case Report

    by Marta Rodrigues de Carvalho, Eduardo Henrique Chiovato Abdala, Carlos Fernando Pereira da Silva Herrero, Narcélio Mendes Ferreira Filho, Vitor Marques Caldas

    Intraoperative neurophysiological monitoring (IONM) is essential in spinal deformity surgery; however, it may be limited in patients with hypomyelinating leukodystrophy and impaired long‐tract conduction. Data on the neurophysiological features of leukodystrophies are scarce. Therefore, we report a case of a 15‐year‐old patient with hypomyelinating leukodystrophy who underwent surgical correction of severe scoliosis (Cobb angle 76°), with a surgical duration of 360 min. During the procedure, transcranial motor evoked potentials (MEPs) and somatosensory‐evoked potentials (SSEPs) could not be obtained despite maximal stimulation parameters, a finding attributed to severe central hypomyelination. In contrast, the bulbocavernosus reflex (BCR) remained reproducible and stable throughout, documenting the integrity of the segmental sacral reflex circuit (S2–S4) and its peripheral innervation. Surveillance was complemented by free‐running electromyography (EMG) and surgeon feedback. The patient had no postoperative neurological deficit, with maintained motor and sphincter function. In patients with hypomyelinating leukodystrophy, the absence of MEPs and SSEPs may not indicate surgical injury but rather reflect impaired long‐tract conduction. The preserved BCR offers a valuable segmental monitoring modality, and a concomitant multimodal strategy—BCR, free‐running EMG, and surgeon feedback—should be considered when evoked potentials are unobtainable. This is the first report detailing intraoperative MEPs and SSEPs findings in this rare population, underscoring the need for adapted IONM protocols in patients with rare and complex neurological comorbidities.

  • Open Access

    Estudo morfométrico do atlas

    by Narcelio Mendes Ferreira Filho, Ricardo Arantes, Anderson Luis Do Nascimento, Carlos Fernando Pereira da Silva Herrero

    Objective To determine the anatomical parameters of the atlas (C1) in a sample of the Brazilian population and compare them with the results already presented in the literature for other populations and, thus, to identify and change the indications of implants used in the treatment of the upper cervical spine. Methods We performed a retrospective observational study of a prospective database, including 100 patients seen between January 2012 and December 2013. We used axial and sagittal sections of computed tomography (CT) scans. The parameters studied were; axial: distance from posterior tubercle to the screw entry point (DPT_EP), safety angle of the axial screw (SA_AS), ideal axial screw length (_ASL) and distance of the spinal canal from the transverse foramen (DSC_TF); Sagittal: ideal sagittal screw length (_SSL), safety angle of the sagittal screw (SA_SS) and posterior arch thickness (_PAT). All of the parameters were divided according to age, gender, and left and right sides. Results The minimum mean point of entry ranged from 20 mm to 22.7 mm. The average security zone ranged from 18.09° to 23.68°. The mean posterior arch thickness ranged from 7.21 mm to 8.95 mm. The lowest averages were found in females. Using an original and reproducible technique of CT evaluation. Conclusion The anatomical parameters of the atlas found in the sample of the studied population were similar to those previously presented in the literature. However, differences between the sexes were observed. ∗ Study developed at the Hospital das Clínicas de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil