Improving detection sensitivity by oriented bioconjugation of antibodies to quantum dots with a flexible spacer arm for immunoassay
- 17 May 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (55) , 50119-50127
Abstract
Antibodies with high targeting capability after being labelled by quantum dots (QDs) have been of great importance for in vitro diagnostic, cellular imaging and in vivo theranostic applications. However, such work concentrating on the conjugation of QDs and antibodies is still insufficient. It is encouraged to develop reliable bioconjugation strategies to improve detection sensitivity of QD–antibody bioconjugates. In this study, two bioconjugation approaches were used for antibody and QDs covalent coupling. Their detection sensitivity was parallelly determined and compared. It was experimentally found that succinimidyl valerate-PEG-maleimide (SMPEG) as the cross linker for oriented bioconjugation of antibodies to QDs with a flexible spacer arm can significantly improve the detection sensitivity of the resulting QD–antibody bioconjugates, compared with those prepared with traditional carbodiimide chemistry using EDC·HCl as the cross linker. Gel electrophoresis suggests antibodies can be successfully conjugated with QDs by both the EDC method and the SMPEG method, but immunofiltration assay shows QD–antibody bioconjugates obtained by the SMPEG strategy have lower detection limits and better linear scope patterns for in vitro molecular diagnosis. In vitro cancer cell imaging further shows that QD–antibody bioconjugates prepared by the SMPEG strategy have superior cell targeting capability without observable nonspecific binding, while the EDC-mediated QD–antibody bioconjugates have low signal to noise ratios with obvious nonspecific cellular binding. Moreover, the number of antibodies conjugated on the surface of QDs was determined by the chemiluminescent dot blot assay, showing 2.13 ± 0.5 and 0.76 ± 0.2 of antibodies per QD by EDC-mediated and SMPEG-mediated coupling, respectively. It further verifies that the SMPEG-mediated coupling strategy can significantly maintain the biological activity of the linked antibodies, even though it has low labelling efficiency. It could be therefore claimed that oriented bioconjugation via the SMPEG coupling strategy is favored by immunoassays, with improved detection sensitivity.Keywords
Funding Information
- National Natural Science Foundation of China (81401754, 81571742, 81371618)
This publication has 43 references indexed in Scilit:
- Microfluidics and nanoparticles based amperometric biosensor for the detection of cyanobacteria (Planktothrix agardhii NIVA-CYA 116) DNABiosensors and Bioelectronics, 2015
- Sensitive detection of carcinoembryonic antigen using surface plasmon resonance biosensor with gold nanoparticles signal amplificationTalanta, 2015
- DNA-functionalized Pt nanoparticles as catalysts for chemically powered micromotors: toward signal-on motion-based DNA biosensorChemical Communications, 2015
- Quantum dots in diagnostics and detection: principles and paradigmsThe Analyst, 2014
- One-pot synthesis of hydrophilic ZnCuInS/ZnS quantum dots for in vivo imagingRSC Advances, 2013
- Effective Reduction of Nonspecific Binding by Surface Engineering of Quantum Dots with Bovine Serum Albumin for Cell-Targeted ImagingLangmuir, 2012
- Biosilicated CdSe/ZnS quantum dots as photoluminescent transducers for acetylcholinesterase-based biosensorsAnalytical and Bioanalytical Chemistry, 2010
- Zwitterionic Biocompatible Quantum Dots for Wide pH Stability and Weak Nonspecific Binding to CellsACS Nano, 2009
- Minimizing Nonspecific Cellular Binding of Quantum Dots with Hydroxyl-Derivatized Surface CoatingsAnalytical Chemistry, 2008
- Surface Modification To Reduce Nonspecific Binding of Quantum Dots in Live Cell AssaysBioconjugate Chemistry, 2005